Laserfiche WebLink
SUPPORTS MANIFOLDED LINES <br /> One transducer per manifolded line is required <br /> THE RED JACKET STP THE REDJACKETSTP <br /> STPs and Piping <br /> Supports a wide-range of pump and pipe types. Utilizes Swiftcheck Valve on early generation Red Jacket Standard STPs. <br /> For further details, click here for the Line Leak Application Guide <br /> Line Leak Transducer Specifications <br /> Operating Temperature -25 OF to +130 OF <br /> • Unleaded Gasoline • Biodiesel (Up to B100) <br /> • Leaded Gasoline • Kerosene <br /> Compatible Fuel Types • 5% Methanol • Jet Fuel <br /> • Up to 100% Ethanol • Aviation Gasoline <br /> • 15% MTBE • DEF <br /> • Diesel <br /> Line Flow Rate 120 GPM Max w/ Swiftcheck Valve <br /> Operating Range 0 — 70 PSI <br /> Proof Pressure 200 PSI <br /> Maximum Vertical Pipeline Height Above Transducer 11 ft <br /> Minimum Pump Output Pressure 23 PSI <br /> Maximum Volume of Fuel Monitored TLS-450PLUS — 1178 gallons <br /> TLS-350 — 212 gallons <br /> TLS450PLUS Line Leak Digital Transducer Ordering <br /> _ i Int-, ids-pf rhli <br /> 859080-001 Digital Pressurized Line Leak Detector (DPLLD) without SwiftCheck Valve, UL <br /> 859080-002 Digital Pressurized Line Leak Detector (DPLLD) with SwiftCheck Valve, UL <br /> 332812-001 16 Input Universal Sensor Module (USM) <br /> 332813-001 5 Universal Input/Output Interface Module (UIOM), Relay Control and Input Signal Monitoring <br /> 332972-007 Ultimate Testing: Digital Line Leak Detection* <br /> 332972-008 Risk Management: Digital Line Leak Detection* <br /> 332972-009 Base Compliance: Digital Line Leak Detection* <br /> 1 Line Leak Analog Transducer Ordering <br /> Part Number W ' A • - -cirrivIR 1566- <br /> 848480-001 Pressurized Line Leak Detector (PLLD) without SwiftCheck Valve, UL <br /> 848480-003 Pressurized Line Leak Detector (PLLD) with SwiftCheck Valve, UL <br /> 330843-001 6 Input Pressurized Line Leak Interface for use with PLLD Module <br /> 330374.001 3 Output Pressurized Line Leak Controller <br /> 330160-010 Ultimate Testing : Pressurized Line Leak Detection (PLLD)* <br /> 330160-060 Risk Management: Pressurized Line Leak Detection (PLLD)* <br /> 330160- 050 Base Compliance: Pressurized Line Leak Detection (PLLD)* <br /> * One per system required for precision line leak detection capability. <br /> NOTE: The TLS-350 analog transducer is not compatible with the TLS-450PLUS ATG . <br /> 125 Powder • Drive a • • Box 200306070 a @2020 • - • • • • • 614 <br /> All information contained in this document is subject to change without notice, <br /> 16888056107942 • ' • <br />