Laserfiche WebLink
ClUtN <br /> x'01' Environmental Health Department <br /> 2 yn z; SAN �JOAQUIN <br /> COUNTY Jasjit Kang, REHS, Director <br /> Muniappa Naidu,REHS,Assistant Director <br /> Greatness grows here. PROGRAM COORDINATORS <br /> Robert McClellon, REHS <br /> Jeff Carruesco, REHS, RDI <br /> Willy Ng, REHS <br /> Steven Shih,REHS <br /> Michelle Henry, REHS <br /> Elena Manzo, REHS <br /> October 14, 2022 <br /> Vince & Lisa Cipponeri <br /> PO BOX 630 <br /> Escalon, CA 95320 <br /> RE: Water Well Pump Inspection <br /> 13 October <br /> Well Location: 8615 S.Via Carano Place, Escalon Permit#: WP0043212 Inspection Date: 2022 <br /> The Environmental Health Department conducted a water well pump inspection at the above address and <br /> found the following code violations at the time of the inspection. In order to protect the ground water and your <br /> drinking water source from potential degradation, please take the associated corrective actions. <br /> ❑ Lack of or inadequate concrete platform around wellhead. <br /> (SJC Water Well Standards, Section 4.10.—Surface Seal) <br /> Corrective Action: Install a concrete surface seal (pedestal) that is a minimum of 4 inches above <br /> grade and extends 2 feet in all directions from the well casing. (About 5'X5') <br /> ❑ Lack of or inadequate sanitary seal at wellhead. <br /> (SJC Ord. Code,Title 9, Section 9-1115.5.—Well Regulations) <br /> Corrective Action: Install a sanitary seal between casing and well cover plate/seal all gaps and <br /> openings. <br /> ❑x Lack of or Inadequate Sampling Tap. <br /> (SJC Water well Standards, Section 4.13.—Sampling Tap) <br /> Corrective Action: Install a non-threaded sampling tap between the wellhead and the check valve <br /> or within three (3) feet of the well head. <br /> ❑ Lack of or inadequate backflow prevention. <br /> (SJC Water Well Standards, Section 4.14.—Backflow Prevention) <br /> Corrective Action: Install an approved protective device to prevent backflow and/or back siphon <br /> into a well. <br /> ❑ Sounding tube or air vent not sealed. <br /> (SJC Water Well Standards, Section 4.13.—Sounding Tube/Air Vent Pipe) <br /> Corrective Action: Sounding Tube or Fill Pipe-Install a watertight, threaded cap at the upper end <br /> of the pipe. Air Vent-extend pipe 12 inches above with end inverted in a <br /> downward direction and covered with 16-mesh screening. <br /> ❑ Excessive vegetation or debris around wellhead. <br /> (SJC Ord. Code, Section 9-1115.4.—Dangerous/Nuisance) <br /> Corrective Action: Remove and maintain debris and vegetation away from well area. <br /> Please contact Aaron Gooderham, REHS, (209) 616-3062, when corrections have been made, and if you <br /> have any questions. <br /> Steven Shih, REHS <br /> Program Coordinator <br /> 1868 E. Hazelton Avenue 1 Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/ehd <br />