My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
2701
>
2300 - Underground Storage Tank Program
>
PR0231176
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/17/2025 2:17:22 PM
Creation date
1/9/2023 10:52:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0231176
PE
2361 - UST FACILITY
FACILITY_ID
FA0003798
FACILITY_NAME
MARCH LANE 76*
STREET_NUMBER
2701
Direction
W
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95219
APN
11619007
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
2701 W MARCH LN STOCKTON 95219
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
126
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJOAQUIN <br />COUNTY— <br />Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />MARCH LANE 76* <br />2701 W MARCH LN, STOCKTON <br />December 07, 2023 <br />Single -Walled Non -Pressurized Piping <br />404 <br />CCR 2643(e), 2661(f) <br />Failure to conduct 0.1 gph test on single -walled gravity piping biennially or post repair (pre -1984) <br />❑ V ❑ R ❑ COS <br />Other Violations <br />2010 <br />See below <br />Unlisted General violation <br />❑ V ❑ R ❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />104 <br />CCR 2632(d)(1), 2634(d) Failure to submit a complete and accurate UST Monitoring Plan. <br />OBSERVATION: The monitoring plan is not current and/or not approved by the EHD. <br />- The 87 & 91 UDC Monitoring was inaccurately listed as continuous <br />- The 87 & 91 & Diesel inaccurately listed a monitoring panel and panel model number. Float and chains are not <br />connected to a monitoring panel. <br />REGULATION GUIDANCE: The monitoring plan must be uploaded to the California Environmental Reporting <br />System (CERS). <br />CORRECTIVE ACTION: Immediately log into CERS, make the necessary changes, and submit for review by the <br />EHD. <br />This is a repeat violation, Class ll. <br />105 <br />CCR 2632(d)(2), 2634(e) Failure to submit a complete and accurate UST Response Plan. <br />OBSERVATION: The response plan is not current and/or not approved by the EHD. <br />- The response plan in CERS did not have section V completed. <br />REGULATION GUIDANCE: The response plan must be uploaded to the California Environmental Reporting System <br />(CERS). <br />CORRECTIVE ACTION: Immediately log into CERS, upload the completed form, and submit for review by the EHD. <br />This is a repeat violation, Class II. <br />FA0003798 PR0231176 SCO01 12/07/2023 <br />EHD 23-01 Rev. 12/06/2021 Page 4 of 9 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.