Laserfiche WebLink
CLIENT: <br /> 4 -11 1/2" O T T INSTALLATION <br /> OSLOPE CONCRETE AWAY FROM ALL MANHOLES 1" RISE OVER 12" RUN. <br /> OFIBER REINFORCEMENT TO BE USED. PREMIX UNIFORMLY THROUGHOUT <br /> CONCRETE. <br /> OREINFORCING BARS TO BE NO LESS THAN 2" AND NO MORE THAN 4" FROM <br /> 3 SURFACE. <br /> 4 REINFORCE CONCRETE SLAB AROUND MANHOLE WITH (4) #4 REBAR 60" IN <br /> 209000 G A L ON C A P AU T O LENGTH. PLACE REBAR 6" FROM SIDES OF BOX. <br /> (I SINGLE 1" CONDUIT TO EACH SUBMERSIBLE PUMP. PROVIDE SEAL-OFF AT <br /> g°? 811 O SUMP & BUILDING WIRING TROUGH. CONTAINS LINE VOLTAGE WIRING. ALL <br /> 8" 8" CONDUIT PENETRATIONS MUST BE MADE WITH ROBROY PVC COATED CONDUIT <br /> >_ » 17 ONLY. <br /> of V ww 22 DIA. MANWAY <br /> o zi <br /> J o D o� ONE 1" STANDARD MONITORING HOMERUN CONDUIT TO EACH TANK. <br /> 2 Ln 42" DIA. FILL SUMP of C > w TANK LIFTING LUGS 48" DIA. TURBINE SUMP FOR STANDARD MONITORING DEVICES, LOOP CONTAINMENT SUMP 11 OF <br /> SENSORS, PLLD, VAC SENSORS & TANK GAUGE TO TANK INTERSTITIAL <br /> BRINE RESERVOIR TANK GAUGE (TYP°) OSENSOR LOCATION AND HOMERUN TO BLDG. PROVIDE SEAL-OFFS IN <br /> AND INTERSTITIAL LOCATION BUILDING & PRIOR TO LEAVING HAZARDOUS AREA. ROUTE TO <br /> MONITOR + ® ® ® ® ® \ INTRINSICALLY SAFE TROUGH IN BUILDING. CONDUITS SHALL CONTAIN <br /> ONLY LOW VOLTAGE WIRING FOR SENSORS. ALL CONDUIT PENETRATIONS ARCO <br /> co% co MUST BE MADE WITH ROBROY PVC COATED CONDUIT ONLY. <br /> - z?tar omKmmm LLC <br /> 0 0 00 ®® ® USE PEA GRAVEL CONSISTING OF NATURALLY ROUNDED AGGREGATE, MIN %" <br /> ANCHOR STRAP + + ®\ �-® ® O & MAX OF %" IN SIZE, FREE OF CLAY, SLAG, CINDERS, OR DEBRIS. ALL <br /> LOCATION (TYP.) 14 SUBSTITUTES MUST BE APPROVED BY MANUFACTURER'S & OWNER'S FIELD <br /> STRAP CHANNEL REPRESENTATIVE. <br /> THROUGH SUMP <br /> TANK 9GHT <br /> 9975LS DRY O8 NOT USED. <br /> �� 13,350 LBS /BRINE NOT USED. ' <br /> o' a' <br /> TANK PAD MINIMUM 2'-0" OFF OUTSIDE WALLS OF TANKS, AND MUST <br /> 10 COVER THE FOOTPRINT OF THE TANKS. REQUIRED TO PROVIDE FOR PROPER <br /> TANK HOLD DOWN, AND TO PREVENT ACCIDENTAL DRILLING INTO TANK. <br /> 11 CUT CORNER WHERE MEETING ASPHALT PAVING ONLY. SQUARE CORNERS <br /> WHERE MEETING CONCRETE. ® � <br /> E�iC� <br /> 12 REFER TO SITE SPECIFIC PLANS FOR ACTUAL PIPE RUNS & NUMBER OF <br /> PRODUCT LINES (1 OR 2 PER UST SUMP). <br /> 18215 72ND AVENUE SOUTH <br /> TURBINE AND FILL SIDE SUMP CONFIGURATION SHOWN IS TYPICAL. FOR KENT, WA 98032 <br /> SPECIFIC DESIGN CRITERIA AT THESE SUMPS SEE ACCOMPANYING TANK (425)251-6222 <br /> INSTALLATION SITE PLAN & SUMP DETAIL DRAWINGS NOTED ABOVE. (425)251-8782 FAX <br /> 10" 16 1/2" (TYP.) O TANK ANCHORING OPTIONAL. CONSULT LOCAL REGULATION; VERIFY WITH <br /> 14 OWNER'S REPRESENTATIVE. CML ENGINEERING, LAND PLANNING, <br /> 5'-6" 5'-6" 6'-10 1/2" 1'-8" 5'-6" 6'-10 1/2" 5'-6 1/4" OVERFLOW PROTECTION: UST OVERFLOW COMPLIANCE IS ACHIEVED BY USE OF40 SURVEYING, ENVIRONMENTAL SERVICES <br /> OVERFLOW PREVENTION DROP TUBE FLAPPER VALVE SET AT 95% AND IS IN NO. DATE REVISION DESCRIPTION <br /> O ACCORDANCE WITH FEDERAL AND STATE GUIDELINES FOR UST OVERFILL <br /> 37'-5 1/2" 15 REQUIREMENTS. i <br /> OPTIONAL MANUFACTURER <br /> ��� SUPPLIED 18"x8"x18' DEADMAN 14 AN OVERFILL ALARM AND ACKNOWLEDGE SWITCH TIED INTO THE VEEDER ROOTUNDERGROUND TANK PLAN 2 <br /> (TYP. OF 4) A B G H FOR MASTER-SLAVE ISTs ON MANIFOLDED LISTS AUTOMATIC TANK GAUGE SYSTEM. THE MONITORING SYSTEM PROVIDES AN 3 <br /> 9y 9 y, A B C FOR OPW FILLS M.5.3.09 M.5.3.09 M.5.3.09 M.5.3.09 USING SINGLE 2 HP TURBINE ON 20K TANK AUDIBLE AND VISUAL ALARM WHEN THE TANK(S) ARE FILLED TO THE 90% <br /> SCALE: 1/2 = 1 -0 M.5.3.93 M.5.3.13 M.5.3.13 (2022 CONFIGURATION) LEVEL. 4 <br /> M.5.3.14 M.5.3.14 M.5.3.14 FOR MASTER-SLAVE ISTs ON MANIFOLDED USTs XX NOTE: y <br /> A B G H USING DUAL 2 HP TURBINES ON 20K TANK O INDICATES ITEMS FOUND ON MATERIALS LIST SHEETS M.5.3.01 & M.5.3.02 <br /> A B C M.5.3.10 M.5.3.10 M.5.3.10 M.5.3.10 2022 CONFIGURATION O <br /> M.5.3.16 M.5.3.16 M.5.3.16 FOR FRANKLIN FUELING ( ) 41,5' 7" CONCRETE SLAB AT <br /> SYSTEMS FILLS _--- 1 <br /> M.5.3.17 M.5.3.1_7M.5.3.17 1 13 A B G H FOR SINGLE IST & SINGLE UST 87.6 LB/CF <br /> 7" THICK CONCRETE(STMP j 2 3 M.5.3.11 M.5.3.11 M.5.3.11 M.5.3.11 (2012 CONFIGURATION) <br /> G 13 6" WIDE DETECTABLE NOTE: <br /> ASPHALT AND STONE PER (TYP.) 3 4 <br /> PROJECT SPECIFICATIONS M.5.3.14 M.5.3.13 UNDERGROUND MARKING CHOSE APPLICABLE DRAWINGS FOR 3.5' DIA. <br /> TAPE BURIED 6"-12" BELOW CONFIGURATION 10 11 (TYP.) I SUMPS 99 <br /> (TYP.) <br /> M.5.3.15 FINISHED GRADE: EMPIRE (TYP.) 1 Q <br /> 10 1 1 TYP. <br /> M.5.3.17 2 <br /> SEAL' <br /> MAGNATEC #31-143 <br /> d <br /> COVER <br /> e. <br /> 4p MIN. <br /> d a <br /> d a, <br /> 4 4 d <br /> d a <br /> a <br /> 0o d <br /> 4 <br /> _ 4 TANK DEPTH �F,� ®l �4, r�• �! <br /> e a °d <br /> bgd d , <br /> 3" PEA GRAVEL MIN. TO 10.5 DIA. 4 1.5' GRAVEL <br /> 1" COND. LOOP TO SUMP 187 189 PREVENT LOAD TRANSFER = I 9,750 LBS COLUMN ch <br /> 7 J-BOX I TO TOP OF TANK C rn <br /> 7 CLI <br /> zo <br /> " 2" INSIDE 3" DOUBLE O I I 7 .67' X 1.5' X 36.0' <br /> 4 FRP RISER TO 166 WALL FRP VACUUM o DEADMAN <br /> GRADE CROSSOVER TO FILL 134 1" FRP BONDED in m <br /> DUAL FLOAT HYDROSTATIC I SUMP FOR VENT & ENTRY FITTING ���• C J V I � <br /> O 6 VAPOR CONTINUOUS TYP. _ " ®F ®� <br /> MONITORING SENSOR 5 (TYP.) <br /> MONITORING - 6 z 12 CA�- <br /> 6 13'-6„ <br /> HOME RUN TOO g <br /> BUILDING HYDROSTATIC 1" FRP BONDED 34 <br /> RESERVOIR ENTRY FITTING <br /> SLOPE SIDES OF TANK HOLE OR (TYP.) D BUOYANCY CALCULATIONS <br /> USE SHORING FOR ALL TANK <br /> EXCAVATIONS IN ACCORDANCE WITH = _ _ - _ _ - CALCULATION BASED ON SUBMERGED WEIGHT OF MATERIALS: <br /> TANK WITH SPHERICAL ENDS, 10.5' O.A. DIA. 10' NOMINAL <br /> OSHA 1926 SUBPART P, OSHA TANK LENGTH: 37' S-1 2" TANK DIAMETER 10'-6" ) <br /> STANDARDS - EXCAVATIONS; FINAL \ / <br /> RULE OCTOBER 1, 1989 <br /> TRY 36'-0" DEADMAN, EACH SIDE, 18" WIDE X 8" HIGH <br /> o _ \\ EMPTY TANK UPLIFT = 20,000 GAL <br /> 2,674 CU FT DEVELOPMENT INFORMATION: <br /> \ � 7.48 GAL./CF <br /> 10 41 00 .4 \\ 2,674 CU FT X 62.4 LBS/CF = 166,858 LBS (DISPLACED WATER) ARC® Wn <br /> �j II ,2 , <br /> TANK SUMP UPLIFT = (2) X 3.14 X 1.75 X 4 - 76.9 CU FT �� am/pm <br /> EXTRACTOR FITTING <br /> ANCHOR STRAP <br /> LOCATION (TYP.) \ // 76.9 CF X 62.4 LBS CU FT = 4,799 LBS DISPLACED WATER FUELS CANOPY <br /> BACKFILL WITH PEAGRAVEL I I „ \\/ TOTAL TANK UPLIFT = 166,858 B = � 6 WD s <br /> LBS �- 4 799 LBS <br /> 171.657 LBS <br /> PER TANK MANUFACTURER ' I TANK LEVEL GAUGE W/ 9 9 <br /> OVERFILL PROTECTION DROP I G@0 " \\ \ <br /> 2 FLOAT KIT. OVERFILL <br /> I I / / <br /> SPECIFICATIONS. (TYP.) (TYP.) 41 15 ALARM AT 90� / / y <br /> //\\//\\ TUBE SET AT 95� TYP. I CAPACITY I \%\\%\ 0 10TANKLD OSLA6 WN CALCULATION <br /> XTI03.5 X 41.5 = 325.0 U <br /> j ! SITE ADDRESS: <br /> \�\%\\%\ P ONAL ALV fJ \\ \\ O 325.0 CU FT X 87.6 LBS CU FT = 28,470 LBS <br /> IP ON P E l \//\\//� / E ALON AVRUE <br /> �� ® CUBED BACKFILL ABOVE TANK: <br /> 4' X 10.5' X 37.5' = 1,575 CU FT = 76.9 CU FT = 1,498.1 CF ©K <br /> ZMAY 20 <br /> 1,498.1 CU FT X 57.6 LBS/ CU FT 82.291 LBS EMM CA <br /> \\ \\ \\ J111 <br /> LL / \//\//\/ ® CURVED BACKFILL ABOVE TANK: <br /> 12"x12"x11GA STEEL STRIKER PLATES TYP. N //\\//\\ 3.14 X 5.25'2X 37.5' = 3,245.5 CU FT FACIM <br /> UNDER ALL OPENINGS W/O MANWAYS ON a 12"x24"x11GA STEEL STRIKER PLATES TYP. \\/\\/� 10.5' X 10.5' X 37.5' = 4,134.4 CU FT <br /> \\ / UNDER ALL OPENINGS W MANWAYS ON /� /� 4,134.4 CU FT - 3,245.5 CU FT = 888.9 CU FT DESIGNED BY: AWANCE z&DM: <br /> o �j/\\//\\ \ FIBERGLASS TANK (BY TANK MANE) / _ \/\\/\ 2 - 444.5 CU FTAL <br /> o \\\�\\ \ z FIBERGLASS TANK (BY TANK MANF.) ; , \//\// CHECKED BY: OV BP REPM: <br /> / `V / a \/\/ 444.5 CU FT X 57.6 LBS CU FT = 25,603 LBS <br /> C)ry / / \ \ / DRAW BY: AWANCE PM: <br /> C) W 0-;//\ \ \` - j/ \//�\///� ® GRAVEL COLUMN ABOVE DEADMEN: AL <br /> + } j\\� \ \ 1.5' X 14.5' X 36.0' X 2 = 1,566 CU FT mad: PROI ECT No <br /> z \/ \ :. a 1�- �- Z� Z� - Z� �- �- �- �f- - �- v'_ /\/\ 1,566 CU FT X 57.6 LBS/ CU FT = 90°201 LBS �m� e� 17223 <br /> o /\\/\\ - 1 -0 MIN. PEA GRAVEL ���� ��� <br /> 0 <br /> 5 <br /> CONCRETE <br /> DEADMEN: <br /> o-\ <br /> . b DRAWING TITLE: <br /> 7 b b <br /> \ \ <br /> INSTALLED OV <br /> ER <br /> TRAPPER• • SCREEN' . _ <br /> O <br /> . 'P <br /> 109 <br /> .67 X 1.5 <br /> X 36.0 36.2 C <br /> COMPACTED SOIL TANK SHALL BE SET DEAD LEVEL' ••• •• •• ••• .• .• / / <br /> \ b / / TYPICAL 20 000 GALLON <br /> 36.2 CU FTX 87.6 S CU <br /> LB FT X <br /> 2 6,342 LBS/ <br /> a•a a,ti ••.a <br /> \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ <br /> \dQq :0.\ \ t \ \ \ \ <br /> DOUBLE WALL FIBERGLASS TANK6 DRY WEIGHT OF TANK: 9,750 LBS INSTALLATION DETAILS <br /> \�/�\�/\\ \\�/�\�/�\�/�\�\�/.�//.�//,�//../i./ /ice//\//\\�/.\//�\//�\//�/�• %//�//.�/ /i./ ,/i./i /� /��//�/i /%//�\//\�/.\//.\�/\�/�\//�/' , /��//./� ,, /../i./i• /, . /�./i /�.//�/�./�.//, / // // // // //,.//i//��//ice///�//,.///// \/ -/ // // // <br /> NATIVE VIRGIN � \/\\/�\/•\/�\��/ / \/� /\/\/�\/\\�\\��\�� <br /> 2 MIN END OF TANK SOIL END OF TANK TOTAL HOLD DOWN: 242°657 LBS <br /> TANK SIZE VARIES WITH MANUFACTURER AND MODEL NUMBER 2' MIN. TOTAL HOLD DOWN: 242.657 LBS _ SHEET NO: <br /> - 1.41 SAFETY FACTOR <br /> 10 1Q <br /> TOTAL TANK UPLIFT: 171,657 LBS <br /> BUOYANCY CAUD-7. 20,000 U`ALo TANK <br /> A° UNDEUROU ND TANK �rSEL,,.MO DETAL SCALE: NTS Mm51,3m03 <br /> SCALE: 1/2" = 1 '-0" <br />