WASTE & VENT PLAN <br />■ <br />SCALE: 1/4" m 114m <br />WATER PLAN 2 <br />SCALE: 1/4" m 11-V L J <br />SLOPE PIPING AS MUCH <br />AS POSSIBLE TOWARD <br />DISCHARGE, TYPICAL <br />INDIRECT WASTE <br />PIPING <br />yl�lly�iI�l:� <br />o ° o <br />FLOOR SINK <br />"P" TRAP <br />FAN COIL <br />PROVIDE CLEANOUTS <br />IN TURNS ANDS OF <br />PIPE, TYPICAL <br />-CONDENSATE <br />PIPING L PROVIDE VENTED <br />P -TRAP AT FAN <br />MIN 2" COIL, TYPICAL <br />�. ROUTE PIPING INCONSPICUOUSLY <br />AND UNOBTRUSIVELY. HANG PIPE <br />AS REQUIRED. DO NOT INSULATE <br />INDIRECT DRAIN PIPE WHEN EX- <br />POSED IN FOOD SERVICE FACILITY. <br />INDIRECT DRAIN TO FLOOR SINK <br />SHUT-OFF VALVE <br />TYP. <br />3/4' PRESSURE AND <br />MPERATURE RELIEF VALVE, <br />RUN DISCHARGE TO MOP SINK <br />16 Gax 2" WIDE STEEL TRAP WITH <br />3/8" DIA x 3" LONG LAG SCREW <br />TO STUDS <br />NOTES: <br />1. PROVIDE DIELECTRIC UNIONS AT <br />ALL CONNECTIONS TO WATER HEATER. <br />2. INSTALL STRAPS AT TOP 1/3 AND <br />BOTTOM 1/3 OF WATER HEATER. <br />G4 <br />CHECK VALVE <br />WATER AND WASTE SERVICE CALCULATIONS <br />JOB NAME: STOP N SAVE LIQUOR & FOOD DATE: 01102/18 <br />FIXTURE TYPE <br />NO. <br />WASTE <br />COLD WATER <br />HOT WATER <br />TOTAL <br />WATER <br />FU <br />TOTAL <br />FU <br />TOTAL <br />FU <br />TOTAL <br />FU <br />FLOOR SINK <br />1 <br />2 <br />2 <br />FS <br />0 <br />WASTE <br />0 <br />0 <br />LAVATORY (SINGLE) <br />1 <br />1 <br />1 <br />0.75 <br />0.75 <br />0.75 <br />0.75 <br />1 <br />SERVICE SINK <br />1 <br />3 <br />3 <br />2.25 <br />2.25 <br />2.25 <br />2.25 <br />3 <br />3 -COMP SINK <br />1 <br />1 0 <br />3 <br />3 <br />3 <br />3 <br />4 <br />WATER CLOSET, 1.6 TANK <br />1 <br />4 <br />4 <br />2.5 <br />2.5 <br />0 <br />0 <br />2.5 <br />HAND SINK <br />1 <br />2 <br />2 <br />2 <br />2 <br />1.5 <br />1.5 <br />2.7 <br />SODA/ ICE <br />1 <br />0.5 <br />0.5 <br />B.G. <br />TOTAL FU <br />12.0 <br />11.0 <br />7.5 <br />13.2 <br />EQUIVALENT COLD WATER FLOW RATE (GPM): 11 <br />ADDITIONAL DEMAND LOAD (GPM) 0 <br />PRESSURE AVAILABLE AT MAIN (PSI): 40 <br />MINIMUM REQUIRED FIXTURE PRESSURE (PSI): 15 <br />ELEVATION RISE (FT): 8 <br />METER LOSS (PSI): 3 <br />BACKFLOW PREVENTER LOSS (PSI): 11 <br />ADDITIONAL LOSSES (PSI): 0 <br />EQUIVALENT PIPE LENGTH FROM METER TO MOST REMOTE FIXTURE (FT 150 <br />FRICTION LOSS PRESSURE AVAILABLE (PSI): 7.53 <br />MAXIMUM ALLOWABLE FRICTION LOSS (PSI1100 FT): 5.02 <br />WATER FLOW VELOCITY (FPS): 4,28 <br />CALCULATED FRICTION HEAD LOSS (PS1/100 FT): 4.16 <br />MINIMUM REQUIRED 'WATER' PIPE SIZE (INCHES): 1,0 <br />MINIMUM REQUIRED 'WASTE PIPE SIZE (INCHES): 2.5 <br />(CALCULATIONS PER THE UPC/CPC) <br />WATER PIPE SIZING CHART <br />PIPE SIZES CALCULATED BASED ON UPG;CPC APPENDIX A <br />SIZE. TYPE L COPPER <br />CW MAX FLOW <br />CW FIXTURE UNIT VALUES <br />HW MAX FLOW <br />HWFU <br />NOMINAL <br />DIAMETER <br />INTERNAL <br />DIAMETER <br />GPM <br />FPS <br />FLUSH TANK <br />FLUSH VALVE <br />GPM <br />FPS <br />HOT WATER <br />V2" <br />0.545 <br />2.3 <br />3.2 <br />1 <br />0 <br />2.3 <br />3.2 <br />1 <br />3/4" <br />0.785 <br />6.0 <br />4.0 <br />7 <br />0 <br />6.0 <br />4.0 <br />7 <br />1" <br />1.025 <br />122 <br />4.7 <br />16 <br />0 <br />12.2 <br />4.7 <br />16 <br />1-1W <br />1.265 <br />21.2 <br />5.4 <br />32 <br />0 <br />50 <br />28 <br />THERMAL <br />EXPANSION TANK <br />WALL <br />\ 2X6 LEDGER <br />ATTACHED TO EA WALL STUD W <br />Y44.5" (1.5" THREAD LENGTH) <br />SIMPSON SDS SCREW <br />WATER HEATER MOUNTING <br />DETAIL <br />SCALE: N.T.S. <br />DEEP ALL -SOLDERED 22 GA <br />V MTL PAN W1 1" DRAIN LINE <br />ATOP SINK BASIN BELOW <br />PLYWO PLATFORM ATEACHED <br />WD J06TS W1 10D 0 8" OC <br /><.4 Q 15' OC JOIST <br />WATER HEATER PLATFORM <br />GENERAL PLUMBING NOTES <br />1. ALL WORK SHALL COMPLY WITH ALL APPLICABLE CODES, SPECIFICATIONS, LOCAL <br />ORDINANCES AND INDUSTRY STANDARDS. <br />2. SEISMIC RESTRAINT: PIPING SHALL BE SUPPORTED AND BRACED IN ACCORDANCE <br />WITH THE CBC AND THE LATEST EDITION OF SMACNA "GUIDELINES" FOR SEISMIC <br />RESTRAINTS OF PLUMBING SYSTEMS AND MECHANICAL SYSTEMS. <br />3. ALL INSULATION AND SEALING PRODUCTS USED IN THE BUILDING SHALL HAVE A SURFACE <br />BURNING CHARACTERISTIC WITH FLAME SPREAD/SMOKE DEVELOPED INDEX OF 25/50 <br />MAXIMUM, WHEN TESTED AS COMPOSITE INSTALLATION INCLUDING INSULATION, TAPES <br />FACING MATERIALS, JACKETS AND ADHESIVES. <br />4. THE ANNULAR SPACE BETWEEN PIPE SLEEVES AND THE PIPE THROUGH ALL RATED WALLS <br />AND FLOORS SHALL BE FIRESTOPPED. FIRESTOPPING OF ALL PIPE PENETRATIONS SHALL <br />COMPLY WITH U.L. REQUIREMENTS. MANUFACTURER PREAPPROVED UL PENETRATION FOR <br />PIPE MATERIAL AND SURFACE PENETRATED SHALL BE USED. PENETRATIONS SHALL BE <br />3M, PROSET, OR APPROVED EQUAL. SUBMIT SHOP DRAWINGS. <br />5. COORDINATE THE FOLLOWING WITH ARCHITECTURAL, STRUCTURAL, PLUMBING AND ELECTRICAL <br />DRAWINGS AND ELEMENTS AS INSTALLED, INCLUDING EXISTING BUILDING SYSTEMS: <br />A. EXACT LOCATION OF ALL EQUIPMENT. <br />B. ALL PENETRATIONS THRU ROOF, WALLS AND FLOORS. <br />C. EXACT SIZE AND ROUTING OF DUCTWORK AND PIPING. <br />6. ALL PIPING LOCATED IN WALLS OR ABOVE CEILING HAVING SHUTOFF VALVES OR OTHER <br />DEVICES REQUIRING ACCESS FOR OPERATION OR MAINTENANCE SHALL BE PROVIDED <br />WITH ACCESS DOORS OF ADEQUATE SIZE FOR SERVICE. <br />7. ANY DAMAGE TO EXISTING BUILDING ARCHITECTURAL, STRUCTURAL, MECHANICAL AND <br />ELECTRICAL SYSTEMS THAT OCCURS DURING THE WORK SHALL BE RESTORED TO THE <br />ORIGINAL CONDITION AT THE CONTRACTOR'S EXPENSE. <br />8. LOCATIONS, SIZES AND DEPTHS SHOWN FOR ALL EXISTING UTILITIES AND EQUIPMENT SHOWN <br />ARE APPROXIMATE ONLY. CONTRACTOR SHALL FIELD VERIFY THE EXACT SIZE, LOCATION <br />AND ADEQUACY OF DEPTH OF ALL EXISTING UTILITIES AND/OR EQUIPMENT SHOWN TO BE <br />CONNECTED TO PRIOR TO BEGINNING WORK. <br />PIPE MATERIAL SCHEDULE <br />A.B. = ABOVE GRADE OQ <br />B.G. =BELOW GRADE gyp? �Gy�• �y� �, � JG <br />'t Q pA Q� Q74 <br />SERVICES GP5 �`� G� GpQ �Gt' REMARKS <br />WATER <br />A.G. <br />LAV <br />EXISTING LAVATORY <br />HS <br />• <br />PROVIDE 1/2" HOT AND COLD WATER PIPING IN WALL SPACE. <br />IAMPO IS 3-89 <br />PROVIDE 1-1/2" WASTE DROP WITH CLEANOUT, AND 1-1/2" VENT RISER <br />B.G. <br />NEW 3 -COMP SINK, <br />PROVIDE 3/4" HOT AND COLD WATER PIPING IN WALL SPACE. <br />• <br />FS <br />IAMPO IS 3-89 W/ BRACED JOINTS <br />WASTE <br />A.G. <br />• <br />MS <br />NEW MOP SINK <br />PROVIDE 3/4" HOT AND COLD WATER PIPING IN WALL SPACE. <br />IAMPO IS 5-90 <br />PROVIDE 2" WASTE DROP AND 1-1/2" VENT RISER <br />B.G. <br />NEW ELECTRIC WATER HEATER: <br />• <br />A.O. SMITH 30 GAL MODEL DEL -30, 4.5KW/4.5KW, 208V/30/60 <br />W/ EXPANSION TANK "AMTROL" MODEL ST -5-C. <br />IAMPO IS 5-90 <br />VENT <br />A.G. <br />• <br />SEE WASTE PIPE <br />B.G. <br />• <br />INDIRECT <br />WASTE <br />A.G. <br />• <br />CONDENSATE PIPING / T&PRV DRAIN <br />GAS <br />A.G. <br />• <br />B.G. <br />s PROVIDE METALLIC PENETRATIONS AT 1 -HR. WALLS AND ALL METALLIC PIPE <br />IN 2 -HR WALLS (I.S. 5-90). <br />PLUMBING <br />nVUM B I N G SCHEDULE. <br />SYMBOL DESCRIPTION <br />WC <br />EXISTING TOILET <br />LAV <br />EXISTING LAVATORY <br />HS <br />NEW HAND SINK <br />PROVIDE 1/2" HOT AND COLD WATER PIPING IN WALL SPACE. <br />PROVIDE 1-1/2" WASTE DROP WITH CLEANOUT, AND 1-1/2" VENT RISER <br />3CS <br />NEW 3 -COMP SINK, <br />PROVIDE 3/4" HOT AND COLD WATER PIPING IN WALL SPACE. <br />PROVIDE 2" INDIRECT DRAIN TO FLOOR SINK <br />FS <br />FLOOR SINK: J.R. SMITH # 325-YO2 WITH CAST IRON BODY, ENAMELED <br />INTERIOR, 6" DEEP SUMP, FLANGE AND SEEPAGE PAN, ALUMINUM <br />BOTTOM DOME STRAINER, HALF GRATE, 2" OUTLET, CAULK JOINT. <br />MS <br />NEW MOP SINK <br />PROVIDE 3/4" HOT AND COLD WATER PIPING IN WALL SPACE. <br />PROVIDE 2" WASTE DROP AND 1-1/2" VENT RISER <br />WH -1 <br />NEW ELECTRIC WATER HEATER: <br />A.O. SMITH 30 GAL MODEL DEL -30, 4.5KW/4.5KW, 208V/30/60 <br />W/ EXPANSION TANK "AMTROL" MODEL ST -5-C. <br />2.1 GALLON TANK VOLUME, 0.43 ACCEPTANCE FACTOR, ASME RATING. <br />VSAC DESIGN <br />PO Boot 199888 <br />Smu.m.kh CA 99810 <br />TN.: 918.7922822 <br />REVISIONS By <br />Drawing <br />PLUMBING <br />, N,.D.... F� <br />ZON <br />NO. C 60696 <br />Exp. 12/31/18 <br />qJ.`•..., CIVIL <br />.F OF <br />Drawn HDV d <br />Date 1 12 18 0 <br />Q <br />Scale 0 <br />Sheet <br />P-1 <br />Sheet No. 1 of Total Sheets <br />