BC234A5COMMON PATH OF TRAVEL DISTANCE= 106'-3"250' COMMON PATH OF TRAVEL ALLOWED FORM OCCUPANCY TABLE 1017.2250' COMMON PATH OF TRAVELALLOWED FOR M OCCUPANCY TABLE1017.2COMMON PATH OF TRAVELDISTANCE= 45'-8"ACTUAL EXIT SEPERATION81'-11"MAXIMUM DIAGONAL DIMENSION OF AREA SERVED = 118'-21/2"MINIMUM EXIT SEPERATION = 49'-7"WORK AREA= 4190.93 SFMERCHANTILE STOCKROOMOCCUPANT LOAD FACTOR= 1/300 SFSTOCKROOM= 4190.93 SF4190.93/300 = 13.96 = 14 OCCUPANTSILLUMINATEDEXIT SIGNILLUMINATEEXIT SIGNMERCHANTILE OCCUPANT LOAD FACTOR = 1/60 SFSALES AREA = 1766.67 SF1766.67/ 60= 29.44= 30 OCCUPANTS1 EXIT REQUIREDOFFICE OCCUPANT LOAD = 1/200 SFOFFICE AREA= 222.64 SF222.64/200= 1.1132 =2 OCCUPANTS2 EXIT REQUIRED0021412"24"60"48"266SALES AREA100OFFICE106OFFICE107MENS103WOMENS104HALL105WORK ROOM102UTILITY109VESTIBULE108FRONT EXITFRONT EXITFRONT EXITFRONT EXITSALES AREA: 1776.67 SQ.FT.OCCUPANT LOAD FACTOR = 601776.67 SQ.FT. / 60 = 29.44= 30 OCCUPANTS1 EXIT REQUIREDWORK AREAS: 4190.93 SQ.FT.OCCUPANT LOAD FACTOR = 3004190.93 SQ.FT. / 300 = 13.96=14 OCCUPANTS1 EXIT REQUIREDOFFICE AREA: 222.64 SQ.FTOCCUPANT LOAD FACTOR= 200222.64 SQ.FT / 200= 1.11= 2 OCCUPANTS1 EXIT REQUIREDRESTROOMS: 120.63 SQ.FT.ACCESSORY USE AREACONTRIBUTION TO TOTAL LOAD = 0TOTAL OCCUPANT LOAD = 46 OCCUPANTSOCCUPANT LOAD CALC.TYPE OF OCCUPANCY:MERCANTILE OCCUPANCYOCCUPANT LOAD FACTORGROUP MPER TABLE 422.1 CPC 2016OCCUPANT LOADSALES AREA =1776.67 SQ. FT. / 60 = 29.44 = 30NON SALES AREA = 4190.93 SQ.FT. / 300 = 13.96 = 14OFFICE AREA= 222.64 SQ.FT. / 200 = 1.11= 2TOTAL OCCUPANT LOAD = 4646 / 2 = 23 EACH SEX OR 23 MALE + 23 FEMALEPLUMBING FIXTURES CALC.PLUMBING FIXTURES AND FIXTURE FITTINGREQUIREMENT PER CPC 2016 TABLE 422.1FIXTUREWATER CLOSETLAVATORIESURINALSDRINKING FOUNTAINSFEMALES REQUIRED1100MALES REQUIRED1100DOOR DESIGNATION - SEE DOOR SCHEDULE ON SHEET A5SYMBOL LEGENDSTOREFRONT DESIGNATION - SEE SCHEDULE ON SHEET A5MATERIAL FINISH DESIGNATION, SEE SHEET A2KEYNOTE DESIGNATIONROOM NAME DESIGNATION?101?Room name101A22018 SCHUSS CLARK BRANDONARCHITECTS, INCORPORATEDcSCHUSS CLARK BRANDON ARCHITECTS, INCORPORATED, EXPRESSLY RESERVE THEIR COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO A THIRD PARTY WITHOUT OBTAINING WRITTEN PERMISSION AND CONSENT OF SCHUSS CLARK BRANDON ARCHITECTS, INCORPORATED SHOULD UNAUTHORIZED RE-USE BY A THIRD PARTY OCCUR, SCHUSS CLARK BRANDON ARCHITECTS, INCORPORATED, SHALL BE HELD HARMLESS.biddingplan chkpermitafterDocument StatusSheet Contentissuepermitrecheckfirstplan checkissued toRevisionsSheet NumberProject:Checked by:Drawn by:Date:rechecksecondPRINTED:1210408 TRINITY PKWY, STOCKTON, CA 952199/26/2018 11:58:17 AMA1.409/26/18AuthorChecker18-442.18CONST DOCSMEANS OFEGRESS FLOORPLANSCALE: 3/16" = 1'-0"1MEANS OF EGRESS