Laserfiche WebLink
48" CLR5/8"NOPARKINGNOPARKINGPARKINGNOVANACCESSIBLEVANACCESSIBLEPROVIDE SECOND SET OF HANDRAILSAT 24" (61) WHEN CHILDREN ARENOTE: MINIMUM STAIR WIDTH = 36"PLATFORMR=1/2"MAX.G.H.F.E.D.C.B.A.CURB RAMPS2J.H.I.G.D.F.E.C.B.E.D.THRESHOLDS211/4" MAX.1/2" MAX.4A.RAMPSI.H.G.F.D.E.WALKS AND SIDEWALKSC.B.3A.34"-38"12"HANDRAILSC.DOORSB.7A.TWSTAIRSR=1/2"MAX.34"-38"TW1 1/2"MAX.12"MAX.1 1/2"60°MAX.R=1/2"TW = TREAD WIDTH (11" MIN.)PRIMARY USERS.34"HAVE CLOSED RISERS.NOTE: ALL STAIRS TO1 1/2"MAX.60°D.20 + 1 FOR EACH 100 OVER 1000NUMBER OF ACCESSIBLEPARKING SPACES REQUIRED201-300C.B.1000+ 1000501-301-401-400500TOTAL NUMBER OFPARKING SPACES75101-151-76-1502001001-26-51-2550PARKING1A.72% OF TOTAL89354621APPROX. 3/4" EXCEPT APPROX.1 1/2" ON SLOPING PORTIONOF RAMPTOP OF RAMPROUNDED1:12 MAX.1/4"SECTION A-A2% MAX.48" MIN.TGROOVING DETAIL12.6 mm1/4"STAIRWAYSC.B.A.5RAMPSALL RAMPS MUST MEET HANDRAIL AND CURB REQUIREMENTS.RAMP WITH TURNING PLATFORM(1:16) 40 FEET INTERVAL MAX.6'-0" MIN.SEE NOTE I60" MIN.TURNING PLATFORMINTERMEDIATE(1:12) 30 FEET(1:20) 50 FEET72" MIN.48" MIN.SEE NOTE JPLATFORM72" MIN.INTERMEDIATE60" MIN.60" MIN.I.J.K.K.(1:16) 40 FEET INTERVAL MAX.PLATFORMBOTTOM LEVEL60" MIN.SEE NOTE JSTRAIGHT RAMP RUN48" MIN.72" MIN.(1:12) 30 FEET(1:20) 50 FEETL.60" MIN.INTERMEDIATE LEVELPLATFORMTOP60" MIN.NOTE: THESE FIGURES ARE ILLUSTRATIVE ONLY AND DO NOT DELINEATE THE ONLYMEANS OF COMPLIANCE. REFER TO PLANS FOR EXACT LAYOUT OF TOILET ROOMS.17"-18"3" MAX.C.B.DRINKING FOUNTAINS12A.B.SHOWN DASHEDFLOOR SPACEMIN. CLEAR30" X 48"32" MIN.CLEAR60" LEVELAND CLEARMIN.MIN.48" MIN. CLR.CLEAR44" MIN.44" MIN.CLEARMIN.48"34" MIN.CLEAR60"36" BARTOILET ACCESSORIESH.G.MIN. REQ.3'-4" MAX.1'-3"12"60" MIN.42"PUBLIC TELEPHONESHEAD ROOM: 80 INCHES MINIMUM.PROTRUDING OBJECTSELECTRICAL11A.C.B.A.9B.A.8FRONT APPROACHSIDE48" MIN.CLEARCLR.32"CLEAR48" MIN.48" MIN.FIGUREVESTIBULE18" MIN12" MIN.F.D.E.SECTION 11B-216.8C.B.b.c.a.PULL SIDEPULL SIDELATCH APPROACHPULL SIDEPUSH SIDE60" MIN.AND LATCH48" IF DOOR44" MIN.HAS CLOSER60" MIN.18" MIN. INTERIOR24" MIN. EXTERIORHINGE APPROACH54" MIN.AND LATCH44" MIN.HAS CLOSER48" IF DOOR24" MIN.60" MIN.PUSH SIDESANITARY FACILITIES13GEOMETRICAL SYMBOLS4.36"3.2.1.A.60" MIN. DIA.OR BY TELEPHONING."18" TO 24"6" DRINKING FOUNTAINS5"MAX.24"18" TOEA. SIDE6" MIN.2'-3" MIN.3'-0" MAX.4'-0" MIN.SPACEFLOORCLEARMIN.2'-8"5"9" MIN.8"MAX.MIN.5" MAX.15"MAX.3'-0" MAX.2'-8" MIN.2'-3" MIN.L.MIN.X > 8"PUSHPROFILE IN WHITE1:121:12MIN.SEE SITE PLAN FOREXACT DIMENSIONMIN.48"*108"MIN.144"MIN.60"ACCESSIBLE SPACES, DOUBLE TYPEWALK36" O.C. TYP.4" WIDE STRIPESBE SERVED BY AN ACCESS AISLEBUT NOT LESS THAN ONE, SHALL"VAN ACCESSIBLE".TYPICAL SYMBOL4'-0" WHEEL BUMPER - TYP.96" WIDE AND SHALL BE DESIGNATEDONE IN EVERY 6 ACCESSIBLE SPACES,48"216" MIN.PROPORTIONSOF ACCESSIBILITYCURB, FENCE, ETC.EACH ACCESSIBLE STALL, TYP.INTERNATIONAL SYMBOLACCESSIBLE PARKING SIGN ATABOVE108"60"1:12MIN.60"1:1248"ACCESSIBLE SPACES, SINGLE TYPEMIN.WALKSINGLE STALL.BE PROVIDED ONSEE TYP. NOTESPASSENGER SIDE FORACCESS AISLE MUST108"MIN.*INTERNATIONAL SYMBOLMIN.144"216" MIN.60"ACCESSIBLE SPACES, DOUBLE DIAGONAL TYPE216" MIN.MIN.48"ON BLUE BACKGROUND4'-0"4'-0"MIN.(1:10 MAX.)FRONT EDGEOF WALKWALKFACE OF CURB4'-0"MIN.A2%MAX.AMIN.12"R=0.375"2.3"-2.4"2.3"-2.4"0.9"-0.92"0.45"-0.47"1:121:10MAX13.5"48"30"CL12"CL18" MIN.TOILET ROOM PLAN17" TO 18"36" BAR MIN.CL42"BARMIN.12"MULTIPLE ACCOMMODATIONCLEARTOILET STALL1 2"MAX.ON DOORPRIVACY LOCK7"-9"42" GRAB BAR19" MIN.33"24"MIN.12"MIN.60"60" DIA.32" MIN. CLR.17"18" MIN.PRIVACY TOILET48" MIN.42"42"60" MIN.MULTIPLE ACCOMMODATIONWITHOUT STOPSROLL PAPER HOLDER17" TO 19"6SIGNSA.B.C.1.2.3.a.b.c.d.4.5.FORWARD REACH REQUIRED30" MIN.48" MIN.27"SIDE REACH POSSIBLEAND BASEOPT. POST48" MAX.30" MIN.ZY27"FULL HEIGHT ENCLOSURE30" MIN.48" MIN.XY48" MAX.NOTE: IF Y < 30 INCHES, THENX SHALL BE > 27 INCHES.48" MIN.48" MAX.Y SHALL BE > 30 INCHES.NOTE: IF Z > 12 INCHES, THEN6APICTOGRAMSC.TTY SYSTEMFOR HEARINGIMPAIRED.VOLUME CONTROLFOR HEARINGIMPAIRED.BRAILLE. CONTRACTED GRADE 2 BRAILLE SHALL BE USED WHEREVER BRAILLE ISREQUIRED IN OTHER PORTIONS OF THESE STANDARDS. DOTS SHALL BE110" (2.54mm)ON CENTERS IN EACH CELL WITH210" (5.08mm) SPACE BETWEEN CELLS, MEASURED FROMTHE SECOND COLUMN OF DOTS IN THE FIRST CELL TO THE FIRST COLUMN OF DOTS INTHE SECOND CELL. DOTS SHALL BE RAISED A MIN. OF140" (0.635mm) ABOVE THEBACKGROUND. BRAILLE DOTS SHALL BE DOMED OR ROUNDED.MOUNTING LOCATION & HEIGHT. WHERE PERMANENT IDENTIFICATION IS PROVIDED FORROOMS AND SPACES, SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THELATCH SIDE OF THE DOOR. WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE,INCLUDING AT DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED ON THE NEARESTADJACENT WALL, PREFERABLY ON THE RIGHT. MOUNTING HEIGHT SHALL BE 48"MIN. ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINEOF THE LOWEST BRAILLE CELLS AND 60" MAX. ABOVE THE FIN. FLR. OR GROUNDSURFACE, MEASURED FROM THE BASELINE OF THE HIGHESTLINE OF RAISED CHARACTERS.CHARACTER TYPE. CHARACTER ON SIGNS SHALL BE RAISED132" (0.794mm) MIN.AND SHALL BE SANS SERIF UPPERCASE CHARACTERS ACCOMPANIED BY GRADE 2BRAILLE. (SEE ITEM 4 BELOW)CHARACTER SIZE. RAISED CHARACTERS SHALL BE A MIN. OF58" (15.9mm) AND AMAX. OF 2" (51mm) HIGH.PICTORIAL SYMBOL SIGNS (PICTOGRAMS). PICTORIAL SYMBOL SIGNS (PICTOGRAMS)SHALL BE ACCOMPANIED BY THE VERBAL DESCRIPTION PLACED DIRECTLY BELOW THEPICTOGRAM. THE OUTSIDE DIMENSION OF THE PICTOGRAM FIELD SHALL BE A MIN.OF 6" (152mm) IN HEIGHT.CHARACTER PLACEMENT. CHARACTERS AND BRAILLE SHALL BE IN HORIZONTALFORMAT. BRAILLE SHALL BE PLACED A MIN. OF38" & MAX. OF12" DIRECTLY BELOWTHE TACTILE CHARACTERS; FLUSH LEFT OR CENTERED. WHEN TACTILE TEXT ISMULTI-LINED, ALL BRAILLE SHALL BE PLACED TOGETHER BELOW ALL LINES OFTACTILE TEXT.FINISH & CONTRAST. CHARACTERS, SYMBOLS & THEIR BACKGROUND SHALL HAVE ANON-GLARE FINISH. CHARACTERS & SYMBOLS SHALL CONTRAST A MIN. OF 70% WITHTHEIR BACKGROUND, EITHER LIGHT ON DARK BACKGROUND OR DARK ON LIGHTBACKGROUND. THE LRV (LIGHT REFLECTANCE VALUE) OF A MATERIALS FINISH SHALL BEDETERMINED BY ASTM E1349-90 (1998) OR EQUAL.PROPORTIONS. CHARACTERS ON SIGNS SHALL HAVE A WIDTH-TO-HEIGHT RATIO OFBETWEEN 3:5 & 1:1 AND A STROKE WIDTH TO HEIGHT RATION OF BETWEEN 1:5 & 1:10.RAISED CHARACTERS & PICTORIAL SYMBOL SIGNS.WHEN SIGNS IDENTIFY PERMANENT ROOMS AND SPACES OF A BUILDING OR SITE, THEYSHALL COMPLY WITH SECTIONS 1 THRU 5 BELOW.WHEN SIGNS DIRECT TO OR GIVE INFORMATION ABOUT PERMANENT ROOMS AND SPACES OFA BUILDING OR SITE, THEY SHALL COMPLY WITH SECTIONS 1 & 2 BELOW.WHEN SIGNS IDENTIFY, DIRECT OR GIVE INFORMATION ABOUT ACCESSIBLE ELEMENTS ANDFEATURES, THEY SHALL COMPLY WITH SECTION 1 & FIGURE 6A, BELOW.MAXIMUM FORCE TO OPERATE DOORS SHALL BE 5LBS PRESSURE. FIRE DOORS SHALL BEMAX 15LBS.LATCHES AND LOCKSETS: PROVIDE LEVER TYPE, PUSH- PULL OR PANIC TYPE HARDWARE34 INCHES TO 44 INCHES ABOVE FLOOR.THRESHOLDS: THE FLOOR OR LANDING SHALL NOT BE MORE THAN 1/2 INCH LOWER THANTHE THRESHOLD OF THE DOOR WAY. CHANGE IN LEVEL BETWEEN 1/4 INCH AND 1/2 INCHSHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2. (SEE BELOW).LEVEL FLOOR OR LANDING: THERE SHALL BE A LEVEL AND CLEAR AREA ON EACH SIDEOF AN EXIT DOOR. THE LEVEL AREA SHALL BE AS SHOWN IN FIGURE 7A. THE SPACEBETWEEN TWO CONSECUTIVE DOOR OPENING (VESTIBULE) SHALL PROVIDE 48 INCHES OFCLEAR SPACE FROM ANY DOOR OPENING INTO SUCH SPACE (SEE BELOW).DOOR WIDTH & HEIGHT: 3 FEET WIDE AND 6 FEET 8 INCHESHIGH. CLEAR WIDTH: 32INCHES MINIMUM WITH DOOR OPEN 90 DEG. MEASURED FROM THE FACE OF THE DOOR TOTHE OPPOSITE STOP.THE BOTTOM 10 INCHES OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING SHALL HAVE ASMOOTH UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIRFOOT- REST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION.INTERIOR STAIRS: MINIMUM 2 INCH WIDE CONTRASTING COLOR STRIPE AT UPPERAPPROACH AND LOWER TREAD OF EACH FLIGHT OF STAIRS TO BE LOCATED 1 INCH FROMNOSING. STRIPE TO BE AS SLIP-RESISTANT AS STAIR TREADS.EXTERIOR STAIRS: CAST IRON (NON-SKID) STAIR NOSINGS MIN. 2" WIDE CONTRASTINGCOLOR STRIPE AT UPPER APPROACH AND AT EVERY TREAD.STAIRWAYS SHALL HAVE HANDRAILS ON EACH SIDE. HANDRAILSMUST BE 1 1/4 INCHESTO 2 INCHES IN CIRCULAR CROSS SECTIONAL DIMENSION AND 4" MIN TO 6 1/4" MAX.FROM THE WALL. EDGES SHALL HAVE A MINIMUM RADIUS OF 1/8 INCHA LEVEL LANDING 4 FEET DEEP SHALL BE PROVIDED AT THE UPPER END OF EACHCURB RAMP OVER ITS FULL WIDTH TO PERMIT SAFE EGRESS FROM THE RAMP SURFACE.ALL CURB RAMPS SHALL HAVE A DETECTABLE WARNING SURFACE. THE DETECTABLEWARNING SURFACE SHALL BE LOCATED SO THE THE EDGE NEAREST THE CURB LINE IS 6INCHES MIN. AND 8 INCHES MAX. FROM THE CURB LINE, AND SHALL EXTEND 36 INCHESIN THE DIRECTION OF TRAVEL AND THE FULL WIDTH OF THE CURB RAMP.THE SURFACE OF EACH CURB RAMP AND ITS FLARED SIDES SHALL BE STABLE, FIRMAND RESISTANT AND SHALL BE OF A CONTRASTING FINISH FROM THAT OF THEADJACENT SIDEWALK. PER CBC SECTION 1127B.5.6EACH PARKING SPACE RESERVED FOR PERSONS WITH PHYSICAL DISABILITIES SHALL BEIDENTIFIED BY A PERMANENTLY AFFIXED REFLECTORIZED SIGN CONSTRUCTED OFPORCELAIN ON STEEL, BEADED TEXT, OR EQUAL, DISPLAYING THE INTERNATIONALSYMBOL OF ACCESSIBILITY. THE SIGN SHALL NOT BE SMALLER THAN 70 SQ. INCHES INAREA AND SHALL BE CENTERED AT THE INTERIOR END OF THE PARKING SPACE AT AMINIMUM HEIGHT OF 80 INCHES FROM THE BOTTOM OF THE SIGN TO THE PARKINGSPACE FINISHED GRADE, OR CENTERED ON THE WALL AT THE INTERIOR END OF THEPARKING SPACE AT A MINIMUM HEIGHT OF 36 INCHES FROM THE PARKING SPACEFINISHED GRADE, GROUND, OR SIDEWALK. A SIGN SHALL ALSO BE POSTED, IN ACONSPICUOUS PLACE, AT EACH ENTRANCE TO THE OFF-STREET PARKING FACILITY, NOTLESS THAN 17 INCHES X 22 INCHES IN SIZE WITH LETTERING NOT LESS THAN 2 INCH INHEIGHT, WHICH CLEARLY AND CONSPICUOUSLY STATES THE FOLLOWING: "UNAUTHORIZEDVEHICLES NOT DISPLAYING DISTINGUISHING PLACARDS OR LICENSE PLATES ISSUED FORPERSONS WITH PHYSICAL DISABILITIES MAY BE TOWED AWAY ATTHE FOLLOWING TABLE ESTABLISHES THE NUMBER OF ACCESSIBLE PARKING SPACESREQUIRED:ASSISTIVELISTENING FORHEARINGIMPAIRED.DIRECTIONAL ARROWWHERE NEEDED TOPROVIDE DIRECTIONOF ACCESSIBLE PATH.INTERNATIONALSYMBOL OFACCESSIBILITY;PROFILE IN WHITE ONBLUE BACKGROUND.CA R100B IS THE ONLY SIGN AUTHORIZED TO BE USED IN THE STATE OF CALIFORNIA.CA R99 FOR PARKING SIGN AND CA R99A FOR THE VAN ACCESSIBLE SIGN.IN ADDITION TO THE ABOVE REQUIREMENTS, THE SURFACE OF EACH PARKING SPACESHALL HAVE A SURFACE IDENTIFICATION, 3 FEET SQUARE, DUPLICATING THE SYMBOLOF ACCESSIBILITY IN BLUE PAINT.SURFACE SLOPES OF PARKING SPACES FOR PERSONS WITH PHYSICAL DISABILITIES SHALLBE THE MINIMUM POSSIBLE AND SHALL NOT EXCEED 1/4 INCH PER FOOT (2% GRADIENT)IN ANY DIRECTION.FLOOR LEVEL AT DOORSSURFACES OF RAMPS SHALL BE SLIP-RESISTANTHANDRAILS SHALL BE PLACED ON EACH SIDE OF EACH RAMP ANDSHALL BE CONTINUOUSTHE FULL LENGTH OF THE RAMP. HANDRAILS SHALL BE 34 TO 38 INCHES ABOVE THERAMP SURFACE AND EXTEND A MINIMUM OF 1 FOOT BEYOND THE TOP AND BOTTOM OF THERAMP.RAMPS SHALL BE NOT LESS THAN 4'-0" WIDE. RAMPS SERVING A PRIMARY ENTRANCE FORAN OCCUPANT LOAD OF 300 OR MORE PEOPLE SHALL BE NOT LESS THAN 5'-0" WIDE.INTERMEDIATE LANDINGS ON STRAIGHT RAMPS SHALL HAVE A DEPTH OF NOT LESS THAN5'-0" INTERMEDIATE LANDINGS ON RAMPS THAT TURN GREATER THAN 30 DEGREES SHALLBE NOT LESS THAN 6'-0" IN DEPTH.INTERMEDIATE LANDINGS SHALL BE PROVIDED AT TURNS AND WHENEVER THE CHANGE INLEVEL EXCEEDS 30 INCHES.THE BOTTOM LANDING SHALL BE NOT LESS THAN 72 INCHES DEEPTHE TOP LANDING SHALL EXTEND NOT LESS THAN 24-INCHES BEYOND THE STRIKE SIDE OFTHE DOOR AT EXTERIOR RAMPS AND 18-INCHES AT INTERIOR RAMPS.THE TOP LANDING SHALL HAVE A WIDTH NOT LESS THAN ITS DEPTH.IF A DOOR SWINGS ONTO A TOP LANDING, THE MIN. LANDING DIMENSION SHALL BE NOTLESS THAN 42 INCHES CLEAR PLUS THE WIDTH OF THE DOOR.THE TOP LANDINGS ON A RAMP MUST BE AT LEAST 60 INCHES X 60 INCHES IN DEPTH.1:12 SLOPED RAMPS SHALL HAVE HANDRAILS ON BOTHSIDES.ANY PATH OF TRAVEL SHALL BE CONSIDERED A RAMP IF ITS SLOPE IS GREATER THAN 1:20(1:12 MAXIMUM)ALL WALKS WITH CONTINUOUS GRADIENTS SHALL HAVE LEVEL AREAS OF AT LEAST 5 FEETIN LENGTH AT INTERVALS OF AT LEAST EVERY 400 FEET.ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE SHALL NOT EXCEED 1/2 INCH.WHEN CHANGES IN LEVEL DO OCCUR, THEY SHALL BE BEVELED WITH A SLOPE NOGREATER THAN 1:2 EXCEPT THAT LEVEL CHANGES NOT EXCEEDING 1/4 INCH MAY BEVERTICAL. WHEN CHANGES IN LEVEL GREATER THAN 1/2 INCH ARE NECESSARY COMPLYWITH THE REQUIREMENTS FOR CURB RAMPS.WHEN THE SLOPE IN THE DIRECTION OF TRAVEL OF ANY WALK EXCEEDS 1 VERTICAL TO 20HORIZONTAL IT SHALL COMPLY WITH THE PROVISIONS FOR PEDESTRIAN RAMPS.WALKS, SIDEWALKS AND PEDESTRIAN WAYS SHALL BE FREE OF GRATING WHENEVERPOSSIBLE. FOR GRATINGS LOCATED IN THE SURFACE OF ANY OF THESE AREAS, GRIDOPENINGS IN GRATINGS SHALL BE LIMITED TO 1/4 INCH IN THE DIRECTION OF TRAFFICFLOW.SURFACE CROSS SLOPES SHALL NOT EXCEED 1/4 INCH PER FOOT.SURFACES WITH A SLOPE OF 6 PERCENT GRADIENT OR GREATER SHALL BE SLIP-RESISTANT.SURFACES WITH A SLOPE OF LESS THAN 6 PERCENT GRADIENT SHALL BE AT LEAST ASSLIP RESISTANT AS THAT DESCRIBED AS A MEDIUM SALTED FINISH.WALKS AND SIDEWALKS SHALL HAVE A CONTINUOUS COMMON SURFACE NOT INTERRUPTEDBY STEPS OR BY ABRUPT CHANGES IN LEVEL EXCEEDING 1/4 INCHAND SHALL BE A MINIMUM OF 4 FEET IN WIDTH.THE SLOPE OF CURB RAMPS SHALL NOT EXCEED 1 VERTICAL TO 12 HORIZONTAL. THESLOPE OF THE FANNED OR FLARED SIDES OF CURB RAMPS SHALL NOT EXCEED 1VERTICAL TO 10 HORIZONTAL. (ADA)CURB RAMPS AT MARKED CROSSINGS SHALL BE WHOLLY CONTAINED WITHIN THEMARKINGS EXCLUDING ANY FLARED SIDES.BUILT-UP CURB RAMPS SHALL BE LOCATED SO THAT THEY DO NOT PROJECT INTOVEHICULAR TRAFFIC LANES.CURB RAMPS SHALL BE A MINIMUM OF 4 FEET IN WIDTH AND SHALL LIE, GENERALLY,IN A SINGLE SLOPED PLANE WITH A MINIMUM OF SURFACE WARPING AND CROSSSLOPE.CURB RAMPS SHALL BE CONSTRUCTED AT EACH CORNER OF STREET INTERSECTIONSAND WHERE A PEDESTRIAN WAY CROSSES A CURB. THE PREFERRED ANDRECOMMENDED LOCATION FOR CURB RAMPS IS IN THE CENTER OF THE CROSSWALK OFEACH STREET CORNER. WHERE IT IS NECESSARY TO LOCATE A CURB RAMP IN THECENTER OF THE CURB RETURN AND THE STREET SURFACES ARE MARKED TO IDENTIFYPEDESTRIAN CROSSWALKS, THE LOWER END OF THE CURB RAMPS SHALL TERMINATEWITHIN SUCH CROSSWALKS.CURB RAMPS SHALL BE LOCATED OR PROTECTED TO PREVENT THEIR OBSTRUCTION BYPARKED CARS.IF DIAGONAL CURB RAMPS HAVE RETURNED CURBS OR OTHER WELL-DEFINED EDGES,SUCH EDGES SHALL BE PARALLEL TO THE DIRECTION OF PEDESTRIAN FLOW.. THEBOTTOM OF DIAGONAL CURB RAMPS SHALL HAVE 48 INCHES MINIMUM CLEAR SPACE. IFDIAGONAL CURB RAMPS ARE PROVIDED AT MARKED CROSSINGS, THE 48 INCH CLEARSPACE SHALL BE WITHIN THE MARKINGS. IF DIAGONAL CURB RAMPS HAVE FLARED SIDES,THEY SHALL ALSO HAVE AT LEAST A 24 INCH LONG SEGMENT OF STRAIGHT CURBLOCATED ON EACH SIDE OF THE CURB RAMP AND WITHIN THE MARKED CROSSING.DETECTABLE WARNING SURFACES SHALL BE DURABLE, SLIP-RESISTANT MATERIAL HAVING ASURFACE TEXTURE COMPOSED OF RAISED, TRUNCATED DOMES ALIGNED IN A SQUARE GRIDPATTERN. TRUNCATED DOMES SHALL HAVE A BASE DIAMETER OF 0.9 INCH MIN. TO 1.4INCHES MAX., A TOP DIAMETER OF 50% MIN. OF THE BASE DIAMETER TO 65% MAX. OF THEBASE DIAMETER, AND A HEIGHT OF 0.2 INCHES. DOMES SHALL HAVE ACENTER-TO-CENTER SPACING OF 1.6 INCHES MIN. AND 2.4 INCHES MAX. AND ABASE-TO-BASE SPACING OF 0.65 INCHES MIN. MEASURED BETWEEN THE MOST ADJACENTDOMES ON THE SQUARE GRID. ONLY APPROVED DSA-AC DETECTABLE WARNING PRODUCTSALL CURB RAMPS SHALL HAVE A GROOVED BORDER 12 INCHES WIDE AT THE LEVELSURFACE OF THE SIDEWALK ALONG THE TOP AND EACH SIDE APPROXIMATELY 3/4 INCHON CENTER. ALL CURB RAMPS CONSTRUCTED BETWEEN THE FACE OF THE CURB ANDTHE STREET SHALL HAVE A GROOVED BORDER AT THE LEVEL SURFACE OF THESIDEWALK.12" HIGH LETTERINGSTATING "NO PARKING"12" HIGH LETTERINGSTATING "NO PARKING"12" HIGH LETTERINGSTATING "NO PARKING"CURB RAMP REQUIRED WHEN WALK ISDIFFERENT LEVEL THAN PARKINGELEVATION. PROVIDE DETECTABLEWARNINGS PER NOTE 2,J THIS SHEET.SIDE FLARE MAX. SLOPE IS 1:10ACCESSIBLE PARKING SIGN (CA R99) ATEACH ACCESSIBLE STALL, TYP. PROVIDEALSO "VAN ACCESSIBLE" SIGN (CA R99A)AT VAN ACCESSIBLE STALLS.TRANSITIONS SHALL BE FLUSH AND FREE OFABRUPT CHANGES IN ELEVATION.IF A WALK CROSSES OR ADJOINS A VEHICULAR WAY, AND THE WALKING SURFACES ARE NOTSEPARATED BY CURBS, RAILINGS OR OTHER ELEMENTS BETWEEN THE PEDESTRIAN AREASAND VEHICULAR AREAS, THE BOUNDARY BETWEEN THE AREAS SHALL BE DEFINED BY ACONTINUOUS DETECTABLE WARNING WHICH IS 36 INCHES WIDE, CONSISTING OF TRUNCATEDDOMES. (SEE DETAIL ON SITE PLAN)SINGLE ACCOMMODATION: A CLEAR FLOOR SPACE OF AT LEAST 60 INCHES INDIAMETER IS REQUIRED FOR SINGLE ACCOMMODATION TOILET ROOMS.THE STRUCTURAL STRENGTH OF GRAB BARS, FASTENERS, AND MOUNTING DEVICESSHALL MEET THE SPECIFICATIONS OF THE AMERICAN DISABILITIES ACT AND THESTATE OF CALIFORNIA TITLE 24.-LOCATE TOILET TISSUE DISPENSERS ON THE WALL WITHIN 7"-9" INCHES OF THEFRONT EDGE OF THE TOILET SEAT.-MOUNT MIRRORS WITH THE BOTTOM EDGE NO MORE THAN 40 INCHES FROMTHE FLOOR.ACCESSORIES: WHERE TOWEL, SANITARY NAPKIN AND WASTE RECEPTACLES ANDSIMILAR DISPENSING AND DISPOSAL FIXTURES ARE PROVIDED, AT LEAST ONE OFEACH TYPE IS TO BE LOCATED WITH ALL OPERABLE PARTS, INCLUDING COINSLOTS, WITHIN 40 INCHES FROM THE FLOOR.LAVATORY: PROVIDE A CLEARANCE OF AT LEAST 29 INCHES FROM THE FLOORTO THE BOTTOM OF THE APRON WITH KNEE CLEARANCE UNDER THE FRONT LIPEXTENDING A MINIMUM OF 30 INCHES WIDE, TO 8 INCHES MINIMUM DEPTH AT THETOP. PROVIDE FOR THE CLEARANCE AT LEAST 30 INCHES WIDE, TO 9 INCHESABOVE THE FLOOR AND 17 INCHES DEEP FROM THE FRONT OF THE LAVATORY.PROVIDE A CLEAR FLOOR SPACE 30 INCHES X 48 INCHES IN FRONT OFLAVATORY. THE CLEAR SPACE MAY EXTEND INTO KNEE AND TOE SPACEUNDERNEATH THE LAVATORY. INSULATE HOT WATER AND DRAIN PIPES UNDERLAVATORIES. NO SHARP OR ABRASIVE SURFACES ARE ALLOWED UNDERLAVATORIES. FAUCET CONTROLS ARE REQUIRED TO BE OPERABLE WITH ONEHAND AND CANNOT REQUIRE GRASPING, PINCHING, OR TWISTING OF THE WRIST.THE FORCE NECESSARY TO OPERATE CONTROLS IS NOT TO EXCEED 5 LB/F.URINALS: PROVIDE ALL WALL HUNG URINALS WITH ELONGATED RIM. FLUSHCONTROLS ARE TO BE HAND OPERATED AND ARE TO MEET THE SAMEREQUIREMENTS AS THE FLUSH CONTROLS FOR THE WATER CLOSET AND ARE TOBE A MAXIMUM OF 44 INCHES ABOVE THE FLOOR. RIM ELEVATION TO BE 17INCHES A.F.F.WATER CLOSET: FLUSH CONTROLS ARE TO BE OPERABLE BY AN OSCILLATINGHANDLE WITH A MINIMUM OPERATING FORCE OF 3 LB/F OR BY A LOW VOLTAGEBUTTON. THE HANDLE OR BUTTON IS TO BE LOCATED ON THE WIDE SIDE SO ASTO BE OPERABLE WITHOUT REQUIRING EXCESSIVE BODY MOVEMENT.ACCESSIBLE COMPARTMENT DOORS SHALL BE EQUIPPED WITH AN AUTOMATICCLOSING DEVICE. THE INSIDE AND OUTSIDEOF THE COMPARTMENT DOOR SHALLBE EQUIPPED WITH A LOOP OR U-SHAPED HANDLE IMMEDIATELY BELOW THELATCH. THE LATCH SHALL BE FLIP-OVER STYLE, SLIDING, OR OTHER HARDWARENOT REQUIRING THE USER TO GRASP OR TWIST.PICTORIAL SYMBOL SIGNS (PICTOGRAMS). PICTORIAL SYMBOL SIGNS(PICTOGRAMS) SHALL BE ACCOMPANIED BY THE EQUIVALENT VERBALDESCRIPTION PLACED DIRECTLY BELOW THE PICTOGRAM. THE BORDERDIMENSION OF THE PICTOGRAM SHALL BE A MINIMUM OF 6 INCHES (152MM) IN HEIGHT.SYMBOL SIZE: RAISED CHARACTERS OR SYMBOLS SHALL BE MINIMUM OF5/8 INCH (15.9 MM) HIGH.LETTER TYPE: LETTERS AND NUMBERS ON SIGNS SHALL BE RAISED 1/32INCH (0.794 MM) MINIMUM AND SHALL BE SANS-SERIF UPPERCASECHARACTERS ACCOMPANIED BY GRADE 2 BRAILLE.RAISED LETTERS SHALL BE PROVIDED AND SHALL BE ACCOMPANIED BY BRAILLEIN CONFORMANCE WITH SECTION 11B-703.4. THEY SHALL BE INSTALLED ON THEWALL ADJACENT TO THE LATCH OUTSIDE OF THE DOOR. WHERE THERE IS NOWALL SPACE ON THE LATCH SIDE, INCLUDING AT DOUBLE LEAF DOORS, SIGNSSHALL BE PLACED ON THE NEAREST ADJACENT WALL, PREFERABLY ON THERIGHT. MOUNTING HEIGHT SHALL BE 60 INCHES ABOVE THE FINISH FLOOR TOTHE CENTER LINE OF THE SIGN. MOUNTING LOCATION SHALL BE DETERMINED SOTHAT A PERSON MAY APPROACH WITHIN 3 INCHES OF SIGNAGE WITHOUTENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF THEDOOR.GEOMETRIC (CIRCLE AND TRIANGLE) SYMBOLS ON SANITARY DOORS SHALL BECENTERED ON THE DOOR AT A HEIGHT OF 60" AND THEIR COLOR AND CONTRASTSHALL BE DISTINCTLY DIFFERENT FROM THE COLOR AND CONTRAST OF THEDOOR.UNISEX SANITARY FACILITIES SHALL BE IDENTIFIED BY A CIRCLE 1/4 INCH THICK,12 INCH DIAMETER, WITH A 1/4" THICK TRIANGLE SUPERIMPOSED ON THE CIRCLEAND WITHIN THE 12 INCH DIAMETER.DOORWAYS LEADING TO MEN'S SANITARY FACILITIES, SHALL BE IDENTIFIED BY ANEQUILATERAL TRIANGLE 1/4 INCH THICK WITH EDGES, 12 INCHES LONG ANDVERTEX POINTING UPWARD. WOMEN'S SANITARY FACILITIES SHALL BE IDENTIFIEDBY A CIRCLE 1/4 INCH THICK WITH EDGES, 12 INCH IN DIAMETER.THE BUBBLER SHALL PROVIDE A FLOW OF WATER AT LEAST 4 INCHES HIGH. ON AFOUNTAIN WITH A ROUND OR OVAL BOWL, THE SPOUT MUST BE POSITIONED SO THE FLOWOF WATER IS WITHIN 3 INCHES OF THE FRONT EDGE OF THE FOUNTAIN.A SECOND DRINKING FOUNTAIN SHALL BE PROVIDED WITH A BUBBLER HEIGHT OF +46"FOR PEOPLE WHO HAVE DIFFICULTY BENDING OR STOOPING.THE BUBBLER CAN BE ACTIVATED BY A HAND OPERATED LEVER LOCATED WITHIN 6INCHES OF THE FRONT OF THE FOUNTAIN OR BY A PUSH BAR ALONG THE FRONT OF THEFOUNTAINFIRE ALARM INITIATING DEVICES SHALL BE 48 INCHES ABOVE THE FLOOR, GROUND ORSIDEWALK.SWITCHES AND CONTROLS FOR LIGHTS, APPLIANCES, COOLING, HEATING ANDVENTILATING EQUIPMENT SHALL BE NOT LESS THAN 3 FEET NOR MORE THAN 4 FEETABOVE THE FLOOR.ELECTRICAL RECEPTACLES (15, 20 AND 30 AMPS) SHALL BE AT LEAST 15 INCHESABOVE THE FLOOR.THE HIGHEST OPERABLE PART OF THE TELEPHONE SHALL BE NO HIGHER THAN 54INCHES WHERE SIDE REACH IS POSSIBLE, AND NO HIGHER THAN 48 INCHES WHEREFORWARD REACH IS REQUIRED.A CLEAR FLOOR OR GROUND SPACE AT LEAST 30 INCHES IN BY 48 INCHES THATALLOWS EITHER A FORWARD OR PARALLEL APPROACH BY A PERSON USING AWHEELCHAIR SHALL BE PROVIDED AT TELEPHONES. BASES, ENCLOSURES, ANDFIXED SEATS SHALL NOT IMPEDE APPROACHES BY PEOPLE WHO USE WHEELCHAIRS.19"MAX.19"MAX.EACH GRADE LEVEL EXTERIOR EXIT DOOR SHALL BE IDENTIFIED BYA TACTILE EXIT WITH THE WORD "EXIT."EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVELEXTERIOR EXIT BY MEANS OF A STAIRWAY OR RAMP SHALL BEIDENTIFIED BY A TACTILE EXIT SIGN WITH THE FOLLOWING WORDSAS APPROPRIATE: 1. "EXIT STAIRS DOWN" 2. "EXIT RAMP DOWN" 3. "EXIT STAIR UP" 4. "EXIT RAMP UP"EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVELEXTERIOR EXIT BY MEANS OF AN EXIT ENCLOSURE OR AN EXITPASSAGEWAY SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITHTHE WORDS "EXIT ROUTE."EACH EXIT ACCESS DOOR FROM AN INTERIOR ROOM OR AREA TO ACORRIDOR OR HALLWAY THAT IS REQUIRED TO HAVE A VISUALEXIT SIGN, SHALL BY IDENTIFIED BY A TACTILE EXIT SIGN WITH THEWORDS "EXIT ROUTE."EACH EXIT DOOR THROUGH A HORIZONTAL EXIT SHALL BEIDENTIFIED BY A SIGN WITH THE WORDS "TO EXIT."CORRESPONDINGTYPE II BRAILLEPROVIDE THIS ADDITIONALSPACE IF DOOR ISEQUIPPED WITH BOTH ALATCH AND A CLOSER.7ACONTROLS AND OPERATING MECHANISM:A. CONTROLS AND OPERATING MECHANISM SHALL COMPLY WITH THE REQUIREMENTS OF SECTION1117B.6.B. THE HIGHEST AND LOWEST OPERABLE PARTS OF ALL CONTROLS, DISPENSERS, RECEPTRACLESAND OTHER OPERABLE EQUIPMEMT SHALL BE PLACED WITHIN 48" OF THE FLOOR BUT NOTLOWER THAN 15" FOR FORWARD APPROACH (OR WITHIN 54" BUT NOT LOWER THAN 9" IFSIDE APPROACH). ELECTRICAL AND COMMUNICATION SYSTEM RECEPTACLES ON WALLS SHALLBE MOUNTED NO LESS THAN 15" ABOVE THE FLOOR. SECTION 1117B.6..3TELEPHONE EQUIPMENT FOR HEARING IMPAIRED PERSONS. TELEPHONES SHALL BEEQUIPPED WITH A RECEIVER THAT GENERATES A MAGNETIC FIELD IN THE AREA OF THERECEIVER CAP. IF BANKS OF PUBLIC TELEPHONES ARE PROVIDED, AT LEAST ONE INEACH BANK AND A TOTAL OF AT LEAST 25% OF THE TOTAL NUMBER OF PUBLICTELEPHONES, INCLUDING CLOSED-CIRCUIT TELEPHONES IN A BUILDING OR FACILITY,SHALL BE EQUIPPED WITH A VOLUME CONTROL. SUCH TELEPHONES SHALL BE CAPABLEOF A MIN. OF 12dBA AND A MAX. OF 18dBA ABOVE NORMAL. IF AN AUTOMATIC RESETIS PROVIDED, 18dBA MAY BE EXCEEDED. PUBLIC TELEPHONES WITH VOLUME CONTROLSHALL BE HEARING AID COMPATIBLE AND SHALL BE IDENTIFIED BY A SIGN CONTAININGA DEPICTION OF A TELEPHONE HANDSET WITH RADIATING SOUND WAVES. SEE FIGURE6A.10PROJECTIONS FROM WALLS WITH LEADING EDGE BETWEEN 27 INCHES AND 80 INCHES ABOVEFLOOR MAY PROJECT 4 INCHES MAXIMUM. LEADING EDGE AT OR BELOW 27 INCHES MAYPROJECT ANY AMOUNT. FREE STANDING PROJECTIONS WITH LEADING EDGE BETWEEN 27INCHES & 80 INCHES ABOVE FLOOR MAY PROJECT 12 INCHES MAX. PROJECTIONS MAY NOTREDUCE MANEUVERING SPACE, OR CLEAR WIDTH OF AN ACCESSIBLE ROUTE.TO BE USED.12" MIN.MAX.24"MIN.MIN.60" CLR.MIN.MIN.MIN.13.5"15"MAX.MIN.MIN.17" TO 18"MAX.MIN.MIN.2.3"-2.4"2.3"-2.4"1:10MAX4'-0"MIN.4 '-0"MI N .216" MIN.DIMENSION OF 2 1/4" MAX. WITH 1 1/2 INCHES CLEARFOR A NON-CIRCULAR SECTIONAL PERIMETER DIMENSION AND CROSS SECTIONEXCEPTION:ACCESS AISLE IS 96 INCHES WIDE MINIMUM.TO BE 108 INCHES WIDE MINIMUM WHERE THEVAN ACCESSIBLE SPACES SHALL BE PERMITTEDEXCEPTION:ACCESS AISLE IS 96 INCHES WIDE MINIMUM.TO BE 108 INCHES WIDE MINIMUM WHERE THEVAN ACCESSIBLE SPACES SHALL BE PERMITTEDwastewastetoweltoweldryersanitarynapkinscupsDISP. OUTLET3' MIN.2018 SCHUSS CLARK BRANDONARCHITECTS, INCORPORATEDcSCHUSS CLARK BRANDON ARCHITECTS, INCORPORATED, EXPRESSLY RESERVE THEIR COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO A THIRD PARTY WITHOUT OBTAINING WRITTEN PERMISSION AND CONSENT OF SCHUSS CLARK BRANDON ARCHITECTS, INCORPORATED SHOULD UNAUTHORIZED RE-USE BY A THIRD PARTY OCCUR, SCHUSS CLARK BRANDON ARCHITECTS, INCORPORATED, SHALL BE HELD HARMLESS.biddingplan chkpermitafterDocument StatusSheet Contentissuepermitrecheckfirstplan checkissued toRevisionsSheet NumberProject:Checked by:Drawn by:Date:rechecksecondPRINTED:110408 TRINITY PKWY, STOCKTON, CA 952199/25/2018 1:31:50 PMG209/26/18EGJB18-442.18CONST DOCSACCESSIBILITYSTANDARDS