Laserfiche WebLink
1801job #date issue description drawn by pm/pic project title consultant architect stampcopyrighttitlesheet architect <br />a l l d e s i g n s , i d e a s , <br />a r r a n g e m e n t s a n d p l a n s <br />i n d i c a t e d b y t h e s e d r a w i n g s <br />a n d s p e c i f i c a t i o n s a r e t h e <br />p r op e r ty a n d copy r i g h t o f t h e <br />ARCHITECT and shall neither <br />be used on any other work nor <br />b e u s e d b y a n y ot he r pe r s o n <br />for any use whatsoever without <br />w r i t t e n p e r m i s s i o n . w r i t t e n <br />d i m e n s i o n s s h a l l t a k e <br />p r e c e d e n c e o v e r s c a l e d <br />d i m e n s i o n s a n d s h a l l b e <br />v e r i f i e d a t t h e j o b s i t e . a n y <br />dimensional discrepancy shall <br />b e b r o u ght t o the at te n ti o n o f <br />t h e A R C H I T E C T p r i o r t o t h e <br />c o m m e n c e m e n t o f w o r k .- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />18.08.27 <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />City Submittal I <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />ISOS <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />WGA <br />- <br />- <br />3702 e. hammer ln. <br />suite c <br />stockton, ca 95212 <br />OWNER: <br />Hammerlane Associates, LLC <br />luv 2 play stockton <br />WGA wendy gilmartin architecture <br />10371 mississippi ave. <br />los angeles ca 90025 <br />323.793.1559 <br />213.334.3950 <br />3 0 7 W . L a t h a m S t r e e t <br />P h o e n i x , A r i z o n a 8 5 0 0 3 <br />w w w .i s o s a r c h i t e c t u r e .c o m <br />B r e n t A r m s t r o n g 4 8 0 3 2 3 6 9 2 8 <br />b r e n t @ i s o s a r c h i t e c t u r e .c o mA6.1ACT CEILINGDETAILSCeiling Grid Notes:1. GC to ensure that the width of the perimeter supportingclosure angle shall be not less than 2 in. In eachorthogonal horizontal direction, one end of the ceiling gridshall be attached to the closure angle. The other end ineach horizontal direction shall have a 0.75 m. clearancefrom the wall and shall rest upon and be free to slide on aclosure angle.2. Lateral bracing for suspended ceiling shall be provided.Where ceiling is not supporting interior partitions, ceilingbracing shall be provided by four No. 12 gauge wiressecured to the main runner within 2 inches of the crossrunner intersection and splayed 90 degrees from eachother at an angle not exceeding 45 degrees from the planeof the ceiling. A strut (adequate to resist the verticalcomponent from lateral loads) fastened to the main runnershall be extended to and fastened to the structuralmembers of the roof or floor. These horizontal restraintpoints shall be placed 12 feet o.c. in both directions withthe first point within 6 feet of each wall. Attachment ofrestraint wires to the structure above shall be adequate forthe load imposed.3. Except where rigid braces are used to limit lateraldeflections, sprinkler heads and other penetrations ,GC toensure a 2" oversize ring, sleeve, or adapter through theceiling tile to allow for free movement of at least 1" in allhorizontal directions. Alternatively, a swing joint that canaccommodate 1" of ceiling movement in all horizontaldirections is permitted to be provided at the top of thesprinkler head extension. See fire sprinkler plans.SPLAY WIRE SECURED TOSTRUCTURE; 45 DEGREEANGLE MAX W/ 4 TIGHTTURNS IN 1-1/2" BOTH ENDSO WIRE. CONNECTED TOMAIN TEES, TYP.UNDERSIDE OFSTRUCTURESPRING CLIP12 ga. VERTICAL HANGERWIRE @ 4'-0" EA. WAYMIN. 3 TIGHT TURNS IN 3"BOTH ENDSMAIN TEECOMPRESSION STRUTSCALE: 01Compression Post Splay WireNTS6 min150MENnot inpictogramfield16-51 LIBRARY 2 5 8"AREA OFREFUGE3/8 min3/8 min9.59.5REFUGEAREA OFAREA OFREFUGE48 min60 max1220 <br />1525 <br />blank cell spacebetween words base diameterdistance between dotsin the same celldistance between dotsin the same celldistance between corresponding dotsin adjacent cellsdistance between corresponding dotsfrom one cell directly belowsingle braillecellraised dotno raised dot18 min45518 min45545°centered ontactile charactersLCNote:See architecture floor plan sheet A0.1 for locations andcount. All dimensions are in inches with millimeters below.Accessibility SignageC-35047C-3504710.31.19