Laserfiche WebLink
14824VHB-PSP-F-ND6' 0"700Deg.12004"12"12001528-0.186"960430 SS100%ALONEALONEHOODNO.TAGMODELLENGTHMAX.COOKINGTEMP.EXHAUST PLENUMTOTALEXH. CFMRISER(S)WIDTHLENG.HEIGHTDIA.CFMVEL.S.P.TOTALSUPPLYCFMHOODCONSTRUCTIONHOOD CONFIG.END TOENDROW12Screw In CompactNONO314LBSHOODNO.TAGFILTER(S)TYPEQTY.HEIGHTLENGTHEFFICIENCY@ 7MICRONSLIGHT(S)QTY.TYPEWIREGUARDUTILITY CABINET(S)LOCATIONSIZEFIRE SYSTEMTYPESIZEELECTRICALMODEL #SWITCHESQUANTITYFIRESYSTEMPIPINGHOODHANGINGWGHT1FIELD WRAPPER 18.00" High Front, Left, RightBACKSPLASH 80.00" High X 72.00" Long 430 SS VerticalHOODNO.TAGOPTION1Front72"14"6"MUAMUA12"12"20"20"4804800.128"0.128"HOODNO.TAGPOS.LENGTHWIDTHHEIGHTTYPERISER(S)WIDTHLENG.DIA.CFMS.P.PATENT NUMBERSAC-PSP Wall (Canada) - CA Patent 2820509AC-PSP (United States) - US Patent 7963830 B2AC-PSP Island (Canada) - CA Patent 25203306' 0"Nom./6' 0.00"OD48"14"18"7"12"20"36"7"12"20"§36"36"24"Ø12"U.L. Listed Screw In CompactFluorescent BulbSEE HOOD TABLE§EXHAUST RISERHANGING ANGLESCREW IN COMPACT FLUORESCENT BULB, L55SERIES E26 CANOPY LIGHT FIXTURE - HIGHTEMP ASSEMBLY, INCLUDES CLEAR THERMALAND SHOCK RESISTANT GLOBE23.5% OPEN STAINLESSSTEEL PERFORATED PANELATTACHING PLATESSUPPLY RISER WITHVOLUME DAMPER6"2 3/4"14"18"BACKSPLASH 80.00" HIGHX 72.00" LONGFIELD WRAPPER 18.00" HIGH(SEE HOOD OPTIONS TABLE)EQUIPMENTBY OTHERS80"24" NOM.48"IT IS THE RESPONSIBILITYOF THE ARCHITECT/OWNER TOENSURE THAT THE HOOD CLEARANCEFROM LIMITED-COMBUSTIBLEAND COMBUSTIBLE MATERIALSIS IN COMPLIANCE WITHLOCAL CODE REQUIREMENTS.1SC-11111002Wall Mount In SS Box05 - SS Wall Mount Box1 Light1 FanSmart Controls BasicSupplyExhaust111.0001.00011511510.210.2NO.TAGPACKAGE #LOCATIONSWITCHESLOCATIONQUANTITYOPTIONFANS CONTROLLEDTYPEɸH.P.VOLTFLACONSULTING MECHANICAL, ELECTRICAL, &PLUMBING ENGINEERS202 Acropolis Way,Vista, CA. 92084(949)-487-0440 (w)(858)-240-4336 (w2)(866)-936-5447 (f)www.proengineeringconsulting.cominfo@proengineeringconsulting.comDESCRIPTION OF OPERATION:3521789Luv 2 Play - Stockton, CASC-111110028/22/2018INSTALLECP #1-1120V 1 Phase w/ control for 1 Exhaust Fan, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire.BREAKER PANEL TO PRIMARY CONTROL PANELResponsibility: ElectricianBREAKER PANELPRIMARY CONTROL PANELBREAKER SIZE SHOWN IS THE MAXIMUM ALLOWEDBREAKER 1PHCONTROL POWER. DO NOT WIRETO GFCI OR SHUNT TRIP BREAKER.HotNeutralH1N1120 V15 AGroundGND1ST HOOD LIGHT BREAKER SHARED W/ CONTROLPOWER. SWITCH #1BREAKER 1PHMCA:MOCP:HotNeutralL1FN1GNDGroundEXH-2115 V12.8 A20 ABREAKER 1PHMCA:MOCP:HotNeutralL2FN2GNDGroundSUP-1115 V12.8 A20 ACONTROL PANEL TO FANSResponsibility: ElectricianPRIMARY PANELFANSLoad WiringWIRE DIRECTTO STARTERWIRE TODISCONNECTFLA:HP:VOLT:T1T2EXH-2LEG 1 / HOTLEG 2 / NEUTRALGNDGROUNDC-102FAN:10.21.000115 VLoad WiringWIRE DIRECTTO STARTERBLACKWHITEGREENWIRE TO FACTORY PROVIDED CONDUIT DROP FLA:HP:VOLT:T1T2LEG 1 / HOTLEG 2 / NEUTRALGNDGROUNDC-2SUP-101FAN:10.21.000115 VCONTROL PANEL TO ACCESSORY ITEMSResponsibility: ElectricianCONTROL PANELCOMPONENTWIRE C1 TO COMMON (1).C1 TO AR1 SHOULD HAVECONTROL PANELFIRE SYSTEMTOMICROSWITCHCONTINUITY WHEN ARMED.IF MORE THAN ONEWIRE AR1 TO NORMALLY CLOSED (2).CAPOFFCAPOFFCAPOFFFIRE SYSTEM, WIREIN SERIES AS SHOWNC1AR1MICROSWITCH 11:C4:NO2:NCMS-11:C4:NO2:NC1:C4:NO2:NCMS-2C1AR1ALL SWITCHES FACTORY WIREDCAT-5 CONNECTIONCONTROL PANELSWITCHESTOJ4CONTROL PANELHOOD LIGHTSTO1400 W MAXWIRE TO J-BOX ON TOP OF HOODB1W1GNDBLACKWHITEGREENHOOD LIGHTS 1THE FOLLOWING CONNECTIONSMAY OR MAY NOT BEREQUIRED BASED ON JOBSITE SPECIFICATIONSCONTROL PANELEXTERNALSIGNAL FORSHUNT TRIPST TERMINAL IS ENERGIZEDIN FIRE CONDITION.STN1NEUTRAL FROM SHUNT COILHOT TO SHUNT COILSHUNT COILSYSTEM DRYSPARE FIRECONTACTCONTROL PANELSPARE CONTACTS WILL MAKE C2 TO AR2 WHEN SYSTEM IS ARMED. THEY ARE USED TO DISABLE EQUIPMENTOR PROVIDE SIGNALS. (NOT FOR BUILDING FIRE ALARM WHICH MUST BE WIRED DIRECTLY TO THE ANSULALARM INITIATING SWITCH LOCATED IN ANSUL AUTOMAN)C2AR2COMMONNORMALLY OPENCONTROL PANELEXTERNALTOSWITCHSIGNAL SWITCH THROUGH BMSWILL ACTIVATE ZONE1 FANS ANDLIGHTSH1IO1BMS SWITCHCNOWHBKBKBKBKCONSULTING MECHANICAL, ELECTRICAL, &PLUMBING ENGINEERS202 Acropolis Way,Vista, CA. 92084(949)-487-0440 (w)(858)-240-4336 (w2)(866)-936-5447 (f)www.proengineeringconsulting.cominfo@proengineeringconsulting.com ABCDEFGHI12345678910FACTORY WIRINGSCHEMATICCIRCUIT BOARDSDCV Rev. 2.09.00HMI Rev. 2.09.00MOTOR POWER CIRCUITPANEL LIDCOMPONENT LISTLABEL DESCRIPTIONPN:RA-x34.110.0184.0120V Relay DPDTPN:ST-XvariesStarterPN:OL-XvariesOverloadPN:C-XvariesContactor120 VACRELAYRA-x24 VDCRELAYRD-xPN:PS-1MDP18-24A-1CPower Sup. 24VDCGRUNLESS SPECIFIED OTHERWISE, ALL FACTORY AC WIRING 16 AWG. ALL FACTORY DC WIRING 18 AWG.N1H1DC-GNDDC+8H17PCU6ST5KS4KTS3GAS2AR11N1120VJ95OV14SF13EF12B11IO1120VJ7H12xN12xAR1GASSTC1B1EF1SF1BKIO1N1N1BKBKBKJUMPERW1BK 14AWGBK64RD-1BLPRDC+RO1PN:RD-x34.110.0188.0 24VDC Light RelayBKWHAR1N1RA-1C-2C-1RD-124V1234567891011121314J6DRY CONTACTS (SHOWN DE-ENERGIZED)RO1HOOD LIGHTSECPM03J10IL1A <br />IL1B JUMPERMAKE UP AIR INTERLOCK.RA-1-1C2AR214 AWGYW14 x 18 x 6 BoxCONTROL INPUT120V H1=LINE,N1=NEUTRAL, 15ABREAKER. DO NOTCONNECT TOSHUNT TRIPBREAKER. SEEINSTALLATIONSCHEMATIC FORADDITIONAL REQ.LEGENDFIELD WIRINGFACTORY WIRINGBK- BLACKBL- B <br />LUEBR- BROWNOR- ORANGEWH- WHITEOR/BL- OR/BL STRIPEBL/RD- B <br />L/RD STRIPERD/GN- RD/GN STRIPEWH/BL- WH/BL STRIPEYW- YELLOWGY- GREYPR- PURPLERD- REDGR- GREENWH/BL <br />BL <br />H1 <br />N1 DC- <br />DC+LN-+PS-01AC24VGND <br />DCPRWH GR/YW <br />WH/BL <br />BL <br />3521789Luv 2 Play - Sto...FACTORYSC-111110028/22/2018ECP #1-2120V 1 Phase w/ control for 1Exhaust Fan, 1 Supply Fan,Exhaust on in Fire, Lights out inFire.BKWHT1T2T3L1L2L31413CONT:FLA:MTR:HP:L1FN1C-114 AWG1 PH20 A115 VEXH-2100-C16D1010.21.000BKWHT1T2T3L1L2L31413CONT:FLA:MTR:HP:L2FN2C-214 AWG1 PH20 A115 VSUP-1100-C16D1010.21.000SHEET NO.SCALE:DWG.#:DRAWNDATE: BY:REVISIONSwww.captiveaire.com <br />ACCORDANCE <br />No. 96 <br />BUILT <br />NFPA <br />WITH <br />IN <br />SLI DTE <br />R3521789MASTER DRAWINGDABLuv 2 Play - Stockton, CA <br />STOCKTON, CA, <br />Southern California Office <br />3002 Dow Ave., Suite 410, Tustin, CA, 92780 PHONE: (714) 957-1500 FAX: (919) 227-5975 EMAIL: reg86@captiveaire.comETL LISTING DESCRIPTION BLOCKVHB HAS BEEN TESTED, LISTEDDEGREE EQUIPMENT FOR A MINIMUM OF 100 CFM PERAND APPROVED TO EXHAUSTTHE CAPTIVE-AIRE MODELNON-GREASE APPLICATIONSLINEAR FOOT OVER 700ETL - VHBFANSLIGHTSCAN MOUNT IN STANDARD DOUBLEGANG JUNCTION BOXALARM INDICATING LCD SCREEN.BUTTON FUNCTIONS VARY BYMODEL TYPE.CAT-5 CONNECTION ON REVERSE.CONNECTED TO HOOD CONTROLPANEL.FANSLIGHTSGAS RESETWASHPUSHTURNLIFTAND14"18"SHEET TITLESCALECHECKED BYJOB NO.SHEET NUMBERSTART DATERP.18-0724PREPARED FOR:The contractor shall verify and beresponsible for all dimensions andconditions on the job and this officemust be notified in writing of anyvariation from the dimensions andconditions shown by these drawings.08/23/18CONSULTING MECHANICAL,ELECTRICAL, & PLUMBING ENGINEERS1120 SYCAMORE AVE, 2AVISTA, CA. 92081(949)-487-0440 (w)(858)-240-4336 (w2)(866)-936-5447 (f)www.proengineeringconsulting.cominfo@proengineeringconsulting.comLUV 2 PLAY <br />STOCKTON <br />3702 E. HAMMER LANE <br />STOCKTON, CA.M0.3MECHANICAL,CAPTIVEAIRE,PART 1