S A N J 0 A Q I I I Irl Environmental Health Department <br /> C o u N T AMENDED <br /> 7/13/2023 <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> UPS-Stockton 1 1532 N Broadway Ave, Stockton May 25, 2023 <br /> Single-Walled Non-Pressurized Piping <br /> 404 CCR 2643(e),2661(f) Failure to conduct 0.1 gph test on single-walled gravity piping biennially or post repair(pre-1984) ❑V ❑R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 104 CCR 2632(d)(1), 2634(d)Failure to submit a complete and accurate UST Monitoring Plan. <br /> OBSERVATION: The monitoring plan is not current and/or not approved by the EHD. <br /> -On CERS the listed leak detector was Vaporless(VMI). On site, a Red Jacket FXIV leak detector was observed. <br /> REGULATION GUIDANCE: The monitoring plan must be uploaded to the California Environmental Reporting <br /> System (CERS). <br /> CORRECTIVE ACTION: Immediately log into CERS, make the necessary changes, and submit for review by the <br /> EHD. <br /> This was corrected on site. <br /> This is a minor violation. <br /> 112 CCR 2638, 26410),2715(f) Failure to have properly qualified service technician test leak detection equipment every <br /> 12 months. <br /> OBSERVATION: The leak detector was replaced between February 09, 2023 through May 25, 2023.A leak <br /> detection testing was not conducted and was completed on 5/25/2023, 3 months past due. <br /> REGULATION GUIDANCE: These tests are required once every 12 months. <br /> CORRECTIVE ACTION: Take all necessary precautions to ensure testing is performed in a timely manner. <br /> This is a Class II violation. <br /> 113 CCR 2637(a-d), 2712(b)(1)(F)Failure to conduct secondary containment testing. <br /> OBSERVATION: The secondary containment testing was not conducted after works was completed for the <br /> SR0082977. <br /> REGULATION GUIDANCE: Secondary containment testing is required to be performed once every 36 months. <br /> CORRECTIVE ACTION: Immediately schedule this test and provide 48 hours notification to the EHD. <br /> This is a Class II violation. <br /> FA0004051 PR0231522 SCO01 05/25/2023 <br /> EHD 23-01 Rev.12/06/2021 Page 4 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />