Laserfiche WebLink
JONES COVEY GROUP, INC . <br /> 9595 Lucas Ranch Rd . - Rancho Cucamonga - California 91730 <br /> RECEIVED <br /> JF Petroleum Group Costco 658 Tracy <br /> 100 Perimeter Park Drive 3250 W Grantline Rd . NOV 2 0 2023 <br /> Suite H <br /> Morrisville , NC 27560 Tracy , CA 95304 ENVIRONMENTAL HEALTH <br /> PERMIT/SERVICES : <br /> 2371956- 1 11 / 13/23 0032033 / 00629991 James W . Blaine <br /> Service Items : <br /> Job Details Call 1 (984 ) 833 5311 when arriving onsite and before departure and reference WO-00629991 <br /> DISP 23-24 HYDRO L 44 Sensor Fuel Alarm , Annular <br /> " Fill out JSA before you start you job" <br /> "You must check in/out with JF Petroleum upon arrival and departure" <br /> " Must fill out the placed in service for any work performed on a dispenser on all service calls . " <br /> " Reminder to log OLD/NEW serial numbers for all component(s ) replaced . Also need to get pump serial numbers that are <br /> worked on . " Photos of the parts that are needed . <br /> " Need to take pictures of the sensor's before/after on all work orders on the component you are working on . Upload into <br /> Flowtrac" <br /> Completion Notes : <br /> 11 /13/23 : 11 . 13 . 23 JWB- Arrived on site , checked in with site & JF Dispatch . Performed analysis on L44 : Fuel Alarm - <br /> D23/24 UDC Hydro & currently this alarm has all 87 & 91 Grade relays in shutdown . This has also caused Q2 : PLLD <br /> Shutdown & Q2 : PLLD Gross Line Fail . This occurred whit someone trying to dispense after L44 : Fuel Alarm had caused <br /> shutdown on VR2 . Performed troubleshooting on L44 Hydro sensor. Found reservoir low & some glycol liquid inside <br /> UDC . Added approximately 32oz of Glycol to reservoir & there looks to be a fast leak rate . Found crack in Bravo <br /> fiberglass under site glass UDC connection under fitting on factory fiberglass work. Will need to drain sump Glycol level <br /> to under leak point , re-fiberglass , allow to cure , & bring back to appropriate level after fiberglass work completed . <br /> Currently on site & unable to keep site out of shutdown with all sensors in normal operating positions . We may be able to <br /> reach out to County to allow us to remove secondary sensor from shutdown to resume GDF operations until repair is <br /> completed . There will be NO need to remove dispenser as it is the highest penetration closest to grade to get to inside <br /> UDC . Prep work & one can of Bravo fiberglass compound should complete job . No Vapor or dispenser removal required . <br /> JCG , Inc. was able to contact County & get setup adjusted approved for a two week timeline for repairs to be performed <br /> & completed , & setup returned to normal configuration . The setup has been edited for L44 D23/24 UDC Secondary Hydro <br /> Sensor removing Fuel/Open/Short alarm conditions to prevent all grades from shutting down . All fueling at site has <br /> resumed & no shutdown alarms currently . I have made temporary repair over penetration to hopefully retain liquid until <br /> fiberglass is fully repaired . Now VR2 showing All Functions Normal . Glycol level now stable from temporary patch & will <br /> continue to monitor with site . If alarm occurs before fiberglass repair is made there will be no shutdowns . BRAVO <br /> FIBERGLASS GLUE KIT REQUIRED . FIBERGLASS REPAIR WORK REQUIRED , ENTIRE SITE CURRENTLY IN <br /> SHUTDOWN , <br /> 11 /13/23 : 11 . 13 . 23_JWB- Arrived on site , checked in with site & JF Dispatch . Performed analysis on L44 : Fuel Alarm- <br /> D23/24 UDC Hydro & currently this alarm has all 87 & 91 Grade relays in shutdown . This has also caused 02 : PLLD <br /> Shutdown & Q2 : PLLD Gross Line Fail . This occurred whit someone trying to dispense after L44 : Fuel Alarm had caused <br /> shutdown on VR2 . Performed troubleshooting on L44 Hydro sensor. Found reservoir low & some glycol liquid inside <br /> UDC . Added approximately 32oz of Glycol to reservoir & there looks to be a fast leak rate . Found crack in Bravo <br /> fiberglass under site glass UDC connection under fitting on factory fiberglass work. Will need to drain sump Glycol level <br /> to under leak point , re-fiberglass , allow to cure , & bring back to appropriate level after fiberglass work completed . <br /> Currently on site & unable to keep site out of shutdown with all sensors in normal operating positions . We may be able to <br /> reach out to County to allow us to remove secondary sensor from shutdown to resume GDF operations until repair is <br />