3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/17/2025 2:44:35 PM
Creation date
1/13/2023 9:39:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0518288
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
3250 W GRANT LINE RD TRACY 95377
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1115
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• Verification of leak monitoring communication for all installed vacuum, pressure, or hydrostatic (VPH) <br />components including piping, sumps, under dispenser containment sumps (UDCs), and all chase <br />lines. Communication at end points of each vacuum zone and each vacuum monitored sump must be <br />verified independently in operating condition. <br />• Verification of the dispenser footprints contained by the UDCs. Any potential leaks from piping and fuel <br />filters must drain directly into UDCs. <br />• Verification of VPH components installation (shroud boots and band clamps for spill containers, <br />appropriate rubber -type gasket or clamps on lids on all fill, vent and STP sumps, etc.). <br />• Verification of overfill prevention: Measurement of drop tubes to verify 95% tank volume shut off and/or <br />verification that external audible/visual alarm activates when tank is 90% full. <br />• Spill bucket test: Verify minimum 5 -gallon capacity and pass a one hour hydrostatic test (or equivalent). <br />Proper drainage method must be verified. <br />• Monitoring system functionality: Functionality of the monitoring system must be verified to ensure it <br />meets the requirements of California Code of Regulations (CCR) Title 23 and California Health & Safety <br />Code (HSC) Chapter 6.7. <br />ELD will be completed (tentatively) on 8-25 and will be submitted for review as soon as reasonably possible. <br />Dates may be merged depending on testing company. <br />Respectfully, <br />'A,# a" <br />Project Superintendent <br />909-276-0789 <br />imalcolm@ionescovey.com <br />JCIN ES COVEY GROUP, INC. <br />This e-mail and any files transmitted with it are the property of Jones Covey Group, Inc are confidential, and are intended solely for the use of the individual or entity to whom this e-mailis addressed. <br />
The URL can be used to link to this page
Your browser does not support the video tag.