Laserfiche WebLink
S A N J 0 A Q I I I Irl Environmental Health Department <br /> CCUN r <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: FD�FLYING J TRAVEL PLAZA#618* 1501 N JACK TONE RD, RIPON 11, 2023 <br /> Single-Walled Non-Pressurized Piping <br /> 404 CCR 2643(e),2661(f) Failure to conduct 0.1 gph test on single-walled gravity piping biennially or post repair(pre-1984) ❑V ❑R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 117 CCR 2637(e), 2637(f)Failed to submit"Secondary Containment Testing Report Form"within 30 days after the test. <br /> OBSERVATION: Secondary containment testing was performed on 11/28/2022.A test report has been submitted to <br /> the EHD or the California Environmental Reporting System (CERS)with missing certifications. <br /> REGULATION GUIDANCE:A copy of the'Secondary Containment Testing Report Form'must be submitted within <br /> 30 days of the test. <br /> CORRECTIVE ACTION: Immediately provide this report to the EHD. <br /> This is a minor violation. <br /> 306 HSC 25291(e)Failure to remove, analyze, and properly dispose of water in secondary containment(pre-Jul 2003). <br /> OBSERVATION: Liquid was observed in the Satellite#25 UDC, Master#21 UDC, Satellite#21 UDC, Satellite#20 <br /> UDC, 91 STP Sump, 87 STP Sump,three diesel STP sumps. <br /> REGULATION GUIDANCE: If water could enter into the secondary containment by precipitation or infiltration, it <br /> must be removed and disposed of properly. <br /> CORRECTIVE ACTION: The service technician removed liquids from the Satellite#25 UDC, Master#21 UDC, <br /> Satellite#21 UDC, Satellite#20 UDC, 91 STP Sump, 87 STP Sump,three diesel STP sump. Ensure that all sumps <br /> and annular spaces are maintained free of liquid. <br /> This was corrected on site. <br /> This is a repeat violation, Class ll. <br /> 311 HSC 2636(a)(1), 25291(b) Monitoring system incapable of detecting leak into secondary containment(pre-Jul <br /> 2003). <br /> OBSERVATION: The 91 and 87 annular sensor failed to activate an audible and visual alarm when tested and, <br /> therefore,the tank is not monitored. <br /> REGULATION GUIDANCE: The UST system shall be designed and constructed with a monitoring system capable <br /> of detecting leaks from primary containment into secondary containment. <br /> CORRECTIVE ACTION: The sensor was replaced and retested during the inspection. <br /> This was corrected on site. <br /> This is a Class II violation. <br /> FA0006672 PR0505264 SCO01 05/11/2023 <br /> EHD 23-01 Rev.12/06/2021 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />