Laserfiche WebLink
P ] Urn SAN J OAQ U I N Environmental Health Department <br /> COUNTY Jasjit Kang , REHS , Director <br /> Greatness grows hese . MuniappaNaidu , REHS , Assistant Director <br /> PROGRAM COORDINATORS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Steven Shih , REHS <br /> Michelle Henry , REHS <br /> Elena Manzo , REHS <br /> April 24 , 2023 <br /> Rob Sills <br /> Jones Covey Group , Inc <br /> 9595 Lucas Ranch Road # 100 <br /> Rancho Cucamonga , CA 91730 Third Amendment on 04/24/2023 <br /> rsills@jonescovey . com <br /> Re : Pilot Travel Centers , LLC SR0086130 <br /> 1501 N Jack Tone Rd , Ripon , CA 95366 <br /> The San Joaquin County Environmental Health Department ( EHD) has completed the review of the <br /> application for a permit to do the following on the underground storage tank ( UST) system at the above <br /> noted address : <br /> • Install BRAVO retrofit entry kits for product and vapor lines inside under dispenser containment <br /> ( UDC) 14/ 15 <br /> • Break concrete and replace annular riser pipe and manway on the 87 (T-4 ) 1 91 (T-5 ) , diesel (T- <br /> 1 ) , and diesel (T- 6) <br /> • Installed ( 8 ) Entry Repair Kits at T-2 Diesel piping sump <br /> The permit has been approved with the following conditions : <br /> 1 . Contact the local fire department , the San Joaquin Valley Air Pollution Control District , and the <br /> San Joaquin County Community Development Department for any applicable permits and <br /> requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ustCc . sigov . org to arrange the following appointments ( a 48- hour <br /> notice is required for inspection appointments) . <br /> a . 24- hour hydrostatic test (or equivalent) on the 14/ 15 UDC sump & T-2 diesel piping sump <br /> b . Since concrete will be broken near the 87 (T-4) , 91 (T- 5 ) , diesel (T- 1 ) , and diesel (T-6 ) , a <br /> secondary containment test must be performed on the 87 (T-4) , 91 (T- 5) , diesel (T- 1 ) , <br /> and diesel (T- 6 ) once concrete is poured in accordance with the manufacturer' s <br /> guidelines . <br /> c . If concrete will be broken near piping and/or sumps , a secondary containment test must <br /> be performed on the piping and/or sumps , once concrete is poured in accordance with <br /> the manufacturer' s guidelines . <br /> 4 . Any individual performing the work of a service technician must meet the following <br /> qualifications : <br /> a . Possess or be employed by a person who possesses one of several permissible valid , <br /> current contractor' s licenses issued by the Contractors State License Board ( may be <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 1 F 209 464 -0138 1 www . sjgov . org /ehd <br />