My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2024 10:29:54 AM
Creation date
1/25/2023 9:27:11 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\lsauers1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
369
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Job Order Field ��/ Jab Order Field <br /> ` <br /> 2257822-1 2257822-1 <br /> .ones Corey Group.Rd. ogress 9 95 Lucas Ra xu Group, <br /> LInProgress <br /> Lucas Raxh Rd. RPr <br /> Ra J,o Cucamonga, CA 91730 Fcrc Cucamonga, CA 91730 <br /> 88&972-7581 pp 1i 11W972-7581 <br /> Flowbac <br /> 2257822-1 Completion Notes: <br /> 11/16/22: 11/16/1022 On sfte for L10 Unleaded Annular sensor out. Upon arrival checked In on kiosk. Veeder Root has no <br /> 1 :1111 go cumenl active alarm for 110, Liquid diagnostics look good as do wiring at Veeder Root. Unable to inspect wiring at annular <br /> Pilot Flying J 618 Ripon Pilot Travel Centers Knoxville Order Date 11/16/22 junction box do to it being corroded/seized. Junction box Itself feels loose and Is likely broken, unable to tell due to backfill, <br /> 1501 N. Jack Tone Road PO Box 10146 recommend repairing likely broken condult riser and replacing explosion proof box. Also observed the tank annular riser to be <br /> Due Date 11/16/22 severely corroded and will need replacement In near future. No other Issues found L10 currently not in alar <br /> Ripon, CA 95366 Knoxville, TN 37939-0146 PO # 160152367 <br /> Payment Net 45 2/6/23 Filiberto: Check in with site management. Met with MD Concrete who was on site to demo concrete around L7, L70, & <br /> Job Details L11 annulars. Preciado on site to begin on conduit/annular wiring repairs. <br /> Description: 2/7/23 CR: Upon arrival notified customer of stype ofwork after began to vac the L11, L7 & L10 annular to replace the riser in <br /> L10. after exposing the riser we noticed it was very corroded and was removed in pieces we had a difficult time removing the <br /> Please let us know If related to ongoing work, the store mentioned uork at pumps 18-19 but we also have a Geared unleaded riser but was able to remove and Install a new fiberglass riser. also in the meanwhile the electricians where having difficult <br /> tank sensor out. <br /> time removing the wire do to the wire looped from ann to ann. They noticed the Conduits looped together from each annular <br /> and existing conduft was impassable. Additional Concrete will need to be demoed out between L10 & Ltt annulars. After <br /> 170 ANNULAR UNLEADED ANN SENSOR OUT ALARM CLEAR NOV 16, 2022 3:52 speaking to our higher authority we got the approval to remove the remainder of the concrete for all the ann. so we can <br /> L10ANNULAR UNLEADEDANN SENSOR OUT ALARM ALARM NOV 16, 2022 3:51 replace the Conduit and all the vire Inside. spoke with MD concrete to get the Concrete demo for the following day. <br /> L29 DISP PAN DISP 19 SATELLITE SENSOR OUT ALARM CLEAR NOV 15, 2022 14:08 <br /> L29 DISP PAN DISP 19 SATELLITE SENSOR OUT ALARM ALARM NOV 15, 2022 13:23. 2/8/23 CR: MD Concrete on site to remove additional Concrete. Started to vac out rest of the pea gravel for L7 and L10. 111 <br /> new FRP annular riser installed. <br /> PO4160125487 <br /> NTE 750.00 2/11/23 CR: upon arrival mi manager of scope of work. We started to look for all the parts that where delivered to the site <br /> we where able to find the fiberglass pipe and to x m. We also where able to excavate half of <br /> WE NEED TO KNOW BEFORE THE NTE IS EXCEEDED. For NTE Issues Please call 865-474-3765 if tech is going to the gravel out of annular 170 L11L12 trenches also cleaned up site. <br /> exceed. <br /> 2122/23 CR: we started to remove the gravel for annulars L11 L12 and removed the existing risers. After removing the users <br /> "If the tech has the part in the warehouse or truck we need to know what the price of the part will be before Installing. if we Installed new users and leveled off the all the annulars to grade. We will returntomorrow to back fill and set mamways to be <br /> deem the cost of your part Is too Costly (before the tech leaves the site) we need the (Description and Part Number) and we ready for Concrete pour back on 2129/23. <br /> will provide the parts needed. If the part In question is Critical to the Compliance of the Fuel System Operation, then the <br /> Equipment Impacted by the faulty Part must remaln dawn, OR Isolated until the Part Is replaced. " 2123123 CR: Backfilled L7, L10, L11, L12 annulars with existing pea gravel. Fine grade pea gravel. Set manways 1 .5" above <br /> If fuel is found In any Containment area or a leak is suspected the HelpDesk must be Ratified Immediately. top of Concrete. Ready for pour back on 2129/23. <br /> "Important" 3/1/2023 JQ Set manway lids, set rebar for Concrete, pour tank slab Concrete <br /> If for any reason you are not going to be able to meet the time line asked for service, I need to know Immediately. I will gel <br /> with another company that can get the Issue resolved in the prescribed period of time needed 11 <br /> Also be ready to vac water if necessary, and if you are not able to vac water on the original call out please reply all to the e- fity <br /> order Order ord <br /> mail that you are not able to accept the wark order for that reason. Product Description quan Order idiom <br /> 'Fill out JSA before you start you job" Labor - Plot Labor 2 <br /> CONSUMABLES Consumables 1 <br /> 'Fill out site survey' Parts Billing (3) ISR 3.5x3.5A - (3) IRI 3.5x2.7A 1 <br /> 'You must check m/out Pilol's kiosk upon arrival and departure. Lodging Lodging F liberto Flores 2.6-2.10 <br /> 1 <br /> Arfare Airfare - Flfiberto Flores 1 <br /> -Must fill out the placed in service for any work performed on a dispenser on all service calls.' <br /> 'Reminder to log OLD/NEW serial numbers for all Component(s)replaced. Also need to get pump serial numbers that are <br /> worked on." Photos of the parts that are needed. <br /> 'Need to take pictures of the sensors before/after on all work orders on the Component you are working on. Upload Into <br /> Job Order Field <br /> 2257822-1 <br /> .ones Currey Group, Inc. <br /> 9595 Luras Ranh Rd. InProgress <br /> Rancho Curamaga, CA 91730 <br /> 888-972-7581 <br />
The URL can be used to link to this page
Your browser does not support the video tag.