Laserfiche WebLink
SAN JOARU <br />.�_,uN I <br />Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />TULARE FARMS LLLP <br />2771 E FRENCH CAMP RD, MANTECA <br />January 20, 2023 <br />Single -Walled Non -Pressurized Piping <br />404 <br />CCR 2643(e), 2661(f) <br />Failure to conduct 0.1 gph test on single -walled gravity piping biennially or post repair (pre -1984) <br />❑ V ❑ R ❑ COS <br />Other Violations <br />2010 <br />See below <br />Unlisted General violation <br />❑ V ❑ R ❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />107 <br />HSC 25292.2; CCR 2711(a)(11) Failure to submit and maintain complete and current financial responsibility <br />documents. <br />OBSERVATION: Current financial responsibility documents were not found on site during the inspection. <br />REGULATION GUIDANCE: A copy of current financial responsibility documents are required to be maintained on <br />site. <br />CORRECTIVE ACTION: Immediately obtain a copy of the facility's financial responsibility documents and maintain a <br />copy on site. <br />This is a repeat violation, Class ll. <br />203 <br />CCR 2712(b)(1-2) Failure to maintain monitoring records for 36 months and maintenance records for 60 months. <br />OBSERVATION: Maintenance and monitoring records for the last three years were not found on site. <br />-The 2022 Monitoring system certification test results were not found on site during the inspection. <br />REGULATION GUIDANCE: These records shall be maintained on site for at least three years. Monitoring records <br />include: (1) date and time of all monitoring or sampling; (2) monitoring equipment calibration and maintenance <br />records; (3) results of any visual observations; (4) results of sample analysis performed a lab or in the field; (5) logs <br />of all readings of gauges or other monitoring equipment, ground water elevations, or other test results; (6) results of <br />inventory readings and reconciliations. <br />CORRECTIVE ACTION: Immediately locate and maintain all missing maintenance and monitoring records for the <br />last three years on site. Submit copies of any missing work orders and alarm records to the EHD. <br />This is a minor violation. <br />FA0003508 PR0234251 SCO01 01/20/2023 <br />EHD 23-01 Rev. 12/06/2021 Page 4 of 5 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />