My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRENCH CAMP
>
2771
>
2300 - Underground Storage Tank Program
>
PR0234251
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2023 12:18:05 AM
Creation date
1/30/2023 10:47:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0234251
PE
2361
FACILITY_ID
FA0003508
FACILITY_NAME
TULARE FARMS LLLP
STREET_NUMBER
2771
Direction
E
STREET_NAME
FRENCH CAMP
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
17710025
CURRENT_STATUS
01
SITE_LOCATION
2771 E FRENCH CAMP RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOARU <br />.�_,uN I <br />Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />TULARE FARMS LLLP <br />2771 E FRENCH CAMP RD, MANTECA <br />January 20, 2023 <br />Single -Walled Non -Pressurized Piping <br />404 <br />CCR 2643(e), 2661(f) <br />Failure to conduct 0.1 gph test on single -walled gravity piping biennially or post repair (pre -1984) <br />❑ V ❑ R ❑ COS <br />Other Violations <br />2010 <br />See below <br />Unlisted General violation <br />❑ V ❑ R ❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />107 <br />HSC 25292.2; CCR 2711(a)(11) Failure to submit and maintain complete and current financial responsibility <br />documents. <br />OBSERVATION: Current financial responsibility documents were not found on site during the inspection. <br />REGULATION GUIDANCE: A copy of current financial responsibility documents are required to be maintained on <br />site. <br />CORRECTIVE ACTION: Immediately obtain a copy of the facility's financial responsibility documents and maintain a <br />copy on site. <br />This is a repeat violation, Class ll. <br />203 <br />CCR 2712(b)(1-2) Failure to maintain monitoring records for 36 months and maintenance records for 60 months. <br />OBSERVATION: Maintenance and monitoring records for the last three years were not found on site. <br />-The 2022 Monitoring system certification test results were not found on site during the inspection. <br />REGULATION GUIDANCE: These records shall be maintained on site for at least three years. Monitoring records <br />include: (1) date and time of all monitoring or sampling; (2) monitoring equipment calibration and maintenance <br />records; (3) results of any visual observations; (4) results of sample analysis performed a lab or in the field; (5) logs <br />of all readings of gauges or other monitoring equipment, ground water elevations, or other test results; (6) results of <br />inventory readings and reconciliations. <br />CORRECTIVE ACTION: Immediately locate and maintain all missing maintenance and monitoring records for the <br />last three years on site. Submit copies of any missing work orders and alarm records to the EHD. <br />This is a minor violation. <br />FA0003508 PR0234251 SCO01 01/20/2023 <br />EHD 23-01 Rev. 12/06/2021 Page 4 of 5 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page