My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRENCH CAMP
>
2771
>
2300 - Underground Storage Tank Program
>
PR0234251
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2023 12:18:05 AM
Creation date
1/30/2023 10:47:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0234251
PE
2361
FACILITY_ID
FA0003508
FACILITY_NAME
TULARE FARMS LLLP
STREET_NUMBER
2771
Direction
E
STREET_NAME
FRENCH CAMP
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
17710025
CURRENT_STATUS
01
SITE_LOCATION
2771 E FRENCH CAMP RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J O A Q U l N Environmental Health Department <br /> tjUNIY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address : Date : <br /> UST System Observations <br /> 312 HSC 25290 . 2(d) Monitoring system incapable of detecting entry into secondary containment (Jul 2003-Jun 2004) ❑ V ❑ R ❑ COS <br /> 313 HSC 25290 . 1 (d) Monitoring system incapable of detecting entry into secondary containment (post-Jul 2004) ❑ V ❑ R ❑ COS <br /> 314 CCR 2631 (g) , 2632(c) Failure to continuously monitor interstitial space with audible-visual alarm system (pre-Jul 2004) ❑ V ❑ R o COS <br /> (2) <br /> 315 HSC 25290. 1 (a) Failure to maintain interstitial space to detect leaks before release to environment (post-Jul 2004) ❑ V ❑ R o COS <br /> 316 CCR 26369 2643(c) (1 ) , Failure to install a line leak detector ❑ V ❑ R o COS <br /> 2666(f) <br /> 317 CCR 2636(f)(2) Failure of the line leak detector to detect a 3 . 0 gph leak at 10 psi and restrict or shut off flow ❑ V ❑ R o COS <br /> 318 CCR 2635, 2637. 1 , Failed to meet spill container requirements o V o R ❑ COS <br /> 2665, 2712 <br /> 319 CCR 2635, 2637. 2, Failure to comply with overfill prevention equipment requirements o V o R ❑ COS <br /> 2665 , 2712 <br /> 320 CCR 2635(c) ( 1 ) Overfill prevention was overridden o V ❑ R ❑ COS <br /> 321 HSC 25299(a) (9) Leak detection equipment disabled or tampered with ❑ V ❑ R ❑ COS <br /> 322 CCR 2717 . 1 (g) Removed , defaced, altered , or otherwise tampered with red tag ❑ V ❑ R ❑ COS <br /> 323 CCR 2717 . 1 (0; HSC Deposited or allowed deposit of petroleum or a hazardous substance into a red tagged UST ❑ V ❑ R ❑ COS <br /> 25292. 3 (c) <br /> 324 HSC 25292. 3(c)( 1 )(C) Allowed dispensing from a UST that has a red tag affixed to the fill pipe ❑ V ❑ R ❑ COS <br /> 325 CCR 2635 , 2636(b) , Failure to comply with the cathodic protection system requirements ❑ V DR ❑ COS <br /> 2662t2712 <br /> 326 CCR 2631 (b&d) , Primary and/or secondary containment not constructed in accordance with the established standards ❑ V o R ❑ COS <br /> 2666(b&e) <br /> 327 CCR 2638(a) , 26410) Leak detection equipment not installed/calibrated/operated/maintained per manufacturer instructions o V o R ❑ COS <br /> 328 CCR 2630 , 2632, 2643 , Equipment or methods used to monitor the UST system are not certified by an independent third-party ❑ V ❑ R o COS <br /> 2644. 1 <br /> 329 CCR 2631 . 1 , 2660(m) UST system not compatible with the substance stored ❑ V ❑ R ❑ COS <br /> 330 CCR 2636(f) , 2666(c) , Failure of emergency generator line leak detector to restrict or shut off flow or trigger an alarm ❑ V ❑ R ❑ COS <br /> 2666 (D <br /> 331 HSC 25281 . 6(a) Failure of unburied below-grade emergency generator system to meet exemption conditions ❑ V ❑ R ❑ COS <br /> 332 HSC 25283. 5(a) Failure of unburied below-grade UST system to meet exemption conditions ❑ V ❑ R o COS <br /> 333 CCR 2666 (b) (2) Failure to upgrade single-walled pipe to double-walled interstitially monitored pipe when repaired ❑ V ❑ R ❑ COS <br /> 334 CCR 2670(b) (e)(0 , 2671 Failure to comply with temporary closure requirements ❑ V o R ❑ COS <br /> 335 HSC 25298(c) ; CCR Failure to comply with all permanent closure requirements ❑ V ❑ R ❑ COS <br /> 2670 , 2672 <br /> 336 CCR 2638(f) , 26410) Failure to affix a tag/sticker on each monitoring equipment certified , repaired , or replaced ❑ V ❑ R o COS <br /> SingleMalled Non -Pressurized Piping <br /> 401 CCR 2636 (a)(3) , Safe suction piping failed to meet slope, check valve location, or inspection requirements o V ❑ R ❑ COS <br /> 2641 (b) <br /> 402 CCR 2643 (d) Failure to conduct monitoring and maintain records for single-walled conventional suction (pre- 1984) ❑ V DR ❑ COS <br /> 403 CCR 2643 (d) , 2661 (f) Failure to conduct 0. 1 gph integrity test for single-walled conventional suction systems (pre- 1984) o V ❑ R ❑ COS <br /> 404 CCR 2643 (e) , 2661 (f) Failure to conduct 0. 1 gph test on single-walled gravity piping biennially or post repair (pre-1984) ❑ V ❑ R ❑ COS <br /> Other Violations <br /> Page 3 of 4 Underground Storage Tank Program OR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 F 209 464-0138 1 www. sjgov. org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.