Laserfiche WebLink
S A N J 0 A Q I I I Irl Environmental Health Department <br /> CCUNT <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> BILLJAR VALERO 153 E ELEVENTH ST,TRACY January 19, 2023 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 208 CCR 2716(a-e) Failure to comply with the designated operator inspection requirements. <br /> 1)OBSERVATION: The designated operator inspections for the following months were performed more than 30 <br /> days after the previous inspection: <br /> - Initial inspection on 7/24/2022, next inspection performed on 8/24/2022(31 days) <br /> - Initial inspection on 8/24/2022, next inspection performed on 9/25/2022(32 days) <br /> - Initial inspection on 10/25/2022, next inspection performed on 11/25/2022 (31 days) <br /> - Initial inspection on 11/25/2022, next inspection performed on 12/26/2022 (31 days) <br /> REGULATION GUIDANCE: The designated operator visual inspections shall be conducted within 30 days or less of <br /> the previous inspection. <br /> CORRECTIVE ACTION: Ensure that all designated operator inspections are performed within the required time <br /> frames. <br /> --------------------------------------------------------------- <br /> 2)OBSERVATION: The designated operator failed to check and note the correct test dates for the overfill prevention <br /> test on the designated operator inspection reports. The overfill prevention test was conducted on 11/9/2022. <br /> REGULATION GUIDANCE: During the inspection, the designated operator shall check that all required testing and <br /> maintenance for the UST system have been completed and document the dates they were done. <br /> CORRECTIVE ACTION: Ensure that designated operators performing inspections at this facility are including all of <br /> the required information on the reports. <br /> This is a repeat violation, Class Il. <br /> 209 CCR 2715(c)(3),2715(c)(4) Failure to maintain a copy of the"Facility Employee Training Certificate"on-site. <br /> OBSERVATION: The Facility Employee Training Certificate dated 1/26/2022 with dates 5/25/2022 and 6/24/2022 <br /> listed underneath does not list employee initial dates or employee dates assuming responsibility. New training <br /> certifications were not created for the trainings conducted on 5/25/2022 and 6/24/2022. <br /> REGULATION GUIDANCE:All site employees must be trained prior to taking responsibility as a facility employee if <br /> after October 1, 2018, or within 30 days of hire if prior to October 1, 2018. The Facility Employee Training <br /> Certificate shall contain accurate information for all employees trained. <br /> CORRECTIVE ACTION: Update the Facility Employee Training Certificate to contain the accurate information and <br /> submit a copy of the updated form to the EHD. <br /> This is a repeat violation, Class II. <br /> FA0003709 PR0231389 SCO01 01/19/2023 <br /> EHD 23-01 Rev.12/06/2021 Page 6 of 7 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />