Laserfiche WebLink
RATIONAL ICP 6-HALF NG 120V 1 PH (LM10013G) Item#E-053 <br /> iCombi Pro 6-half size E/G <br /> Technical specifications <br /> Dimensions and weights Connected loads-gas <br /> Dimensions(W x H x D) Voltage 2 AC 208 V <br /> Cooking system(body) 33 1/2 x 29 5/8 x 30 1/2 inches Connected loads-gas 0.6 kW <br /> Cooking system(total) 33 1/2 x 31 5/8 x 33 1/8 inches Breaker 15A <br /> Cooking system with packaging 36 3/4 x 37 3/4 x 37 5/8 inches RCD Type B <br /> Maximum working height of top level' <-5 ft.2 7/8 inches Voltage 1 NAC 120V <br /> `When using an original RATIONAL stand Connected loads-gas 0.6 kW <br /> Breaker 15 A <br /> Weights RCD Type F <br /> Maximum load size per level 331b <br /> Maximum total load capacity 661b All gas units are supplied with cord. <br /> Weight-electric unit without packaging 218 Ib Connection conditions water <br /> Weight-electric unit with packaging 257 Ib <br /> Water inlet(pressure hose),each 3/4" <br /> Electrical connection conditions Water pressure(flow pressure),each 14.5-87.0 psi <br /> Voltage 3 AC 208 V/240 V Water drain,each 2"OD <br /> Connected loads-electric 10.8 kW Maximum flow rate per cooking system 3.17 gal/min <br /> Steam power 9 kW Water quality requirements <br /> Convection power 10.25 kW Untreated water can be 0 to 24.5 gr/gal(0 to 420ppm)hardness.We do <br /> Breaker 35A not recommend treated water hardness<5 gr/gal(86ppm)because the <br /> RCD type B water could be corrosive.Sodium ion exchangers are not recommended; <br /> H+Ion exchange systems are recommended.Water that does not meet <br /> Cable diameter AWG 8140°F the following minimum standards will require the proper conditioning <br /> Voltage 3 AC 440 V/480 V <br /> Contaminant Water Requirements If>than recom- <br /> Connected loads-electric 10.8 kW mended <br /> Steam power 9 kW <br /> Sand/Particles <15 Nm Particle filter <br /> Convection power 10.25 I<W Chlorine(Cl2) <0.12 gr/gal(0.2 ppm) Active carbon filter <br /> Breaker 20A Chloride(CI-) <4.68 gr/gal(80 ppm) RO <br /> RCD type B <br /> Cable diameter AWG 14 140°F Connected loads-exhaust air and thermal load <br /> Voltage 2 AC 208 V/240 V Latent heat load 1943 BTU <br /> Connected loads-electric 10.8 kW Sensible heat emission 2391 BTU <br /> Steam power 9 kW Sound level(electric) 55 dBA <br /> Convection power 10.25 kW Sound level(gas) 60 dBA <br /> Breaker 60 A <br /> RCD type B Connection loads-data <br /> Cable diameter AWG 4 140°F LAN data interface RJ45 <br /> Not supplied with cable connection <br /> WiFi data interface IEEE 802.11 a/g/n <br /> Minimum distances at installation _ <br /> Clearance Requirements <br /> Connected loads-gas To facilitate servicing,we recommend leaving a 20"(500 mm)gap on the <br /> left-hand side of the unit.If there is not 20"(500 mm)left side clearance <br /> Natural gas G20 available,provisions for moving the unit to the left for service access o <br /> Nominal heat load,total 49500 BTU must be made.Such provisions include,but are not limited to,having <br /> Nominal heat load,Steam mode 45500 BTU quick connections(water,gas,etc.)and lengthened electrical connections v <br /> Nominal heat load,Hot Air mode 49500 BTU with flexible cords. <br /> If there are no external heat sources acting on the unit,there should be at v <br /> Required connection Flow pressure 6.5-10 inch w.c. least 2"(50 mm)of clearance on either side of the unit.The back of the <br /> 3 <br /> Liquid gas unit can be mounted flush with the wall. <br /> a <br /> Nominal heat load,total 48500 BTU If a high temperature heat source is on the left side of the unit,clearance <br /> Nominal heat load,Steam mode 44500 BTU of at least 14"(350 mm)must be maintained on the left-hand side.This o <br /> N <br /> clearance may be reduced to 2"(50 mm)if a heat shield is used(see <br /> Nominal heat load,Hot Air mode 48500 BTU o <br /> accessories). M <br /> Required connection flow pressure 10-15 inch w.c. <br /> Recommended clearance From unobstructed rear exhaust pipes and any <br /> 3/4"NPT with 3/4"gas shut off surface collecting grease or flammable material;16"(400 mm)gas, <br /> Additional gas types and voltages available on request 10"(254 mm)electric.It is recommended to have a hood overhang of `s <br /> 6"(150 mm)to 18"(450 mm)at the front of the unit and 6"(150 mm)on <br /> a <br /> v <br /> 4/8 <br /> Den-Stockton 03/03/2022 ADVANTAGE EQUIPMENT SALES-LLC Page:95 <br />