REVISIONS
<br /> JOB NO MODEL NUMBER DRAWN BY SCHEMATIC TYPE DESCRIPTI❑N OF OPERATION: JOB NO MODEL NUMBER DRAWN BY SCHEMATIC TYPE DESCRIPTION OF ❑PERATI❑N: DESCRIPTION DATE:
<br /> DCV-2111 INSTALL Fire System #1 TANK FS - 4.0/4.0/4.0. Tank-based Fire Protection System equipped with Electronic Detection utilizing DCV-21.11 INSTALL Fire System #1 TANK FS - 4.0/4.0/4.0. Tank-based Fire Protection System equipped with Electronic Detection utilizing
<br /> 5274758 DATE DWG NO CORE board as a Listed Release Mechanism. Installed In Hood Mounted Utility Cabinet separate from prewire. 5274758 DATE DWG NO CORE board as a Listed Release Mechanism. Installed In Hood Mounted Utility Cabinet separate from prewire. Q
<br /> JOB NAME DENNY'S - STOCKTON, CA Includes 12' box housing circuit board, batteries, and terminals for connection to main control panel. JOB NAME DENNY'S - STOCKTON, CA Includes 12' box housing circuit board, batteries, and terminals for connection to main control panel.
<br /> 1/17/2022 ECP #1-4 1/17/2022 ECP #1-5 0
<br /> 1 1
<br /> TANK PROTECTION LOW-VOLTAGE DETAIL 02/10/2021 Rev, 2 TANK PROTECTION ELECTRICAL DETAIL 02/10/2021 Rev, 2
<br /> 2 2
<br /> ALARM CONTRACTOR: ELECTRICIAN:
<br /> ACTUATION1. WIRE MANUAL REMOTE FIRESTAT(S), CORE INTERLOCK(S), FIRE SENSOR1, WIRE MAIN CONTROL PANEL PER INCLUDED SCHEMATIC
<br /> 3 2. COMPLETE FINALHOOKUP OF SYSTEM S) AND FIRE ALARM CONTACTS FS-1: MASTER 3 F S—1: MASTER
<br /> S T E R
<br /> 2, WIRE ALL FANS PER INCLUDED SCHEMATIC !=€E�
<br /> 3. VERIFY FINAL FIRE SYSTEM TEST 3. WIRE SHUNT TRIP BREAKER (OPTIONAL)
<br /> 4, WIRE UDS APPLIANCE KILL SWITCH, IF EQUIPPED (OPTIONAL) I I I I I I
<br /> 5, WIRE GAS VALVE
<br /> 4 ALARM CONTRACTOR REQUIREMENT 4 a � Q a1<1 � Q
<br /> ELECTRICAL CONTRACTOR REQUIREMENT
<br /> 5 ITEM CONNECTION IN PANEL CONNECTION ON DEVICE VOLTAGE AMPERAGE COMMENTS 5 ITEM CONNECTION IN PANEL CONNECTION IN DEVICE VOLTAGE AMPERAGE COMMENTS REVISIONS
<br /> 101 AND 104 WIRE MANUAL ACTUATION DEVICE TERMINAL 1 BETWEEN CORE PANEL TERMINALS 102 AND 103 BREAKER COIL E
<br /> MANUAL ACTUATION DEVICES) 1 & 2 24 VDC < 1,0 AMPS WIRE MANUAL ACTUATION DEVICE TERMINAL 2 BETWEEN CORE PANEL TERMINALS 101 AND 104 SHUNT TRIP BREAKER (OPTIONAL) ST & N1 120 VAC < 4 AMPS ST TO Al ON SHUNT BREAKER COIL, AND NEUTRAL TO A2 ON SHUNT TRIP BREAKER COIL O
<br /> 102 AND 103 JUMPER 101 TO 104 AND 102 TO 103 IF NO MANUAL ACTUATION DEVICE IS INSTALLED (Al & A2) U E w In o w vi m o vi o •0 1vi
<br /> s MANUAL ACTUATION DEVICE COVER MUST BE INSTALLED e CONTROL PANEL POWER H1 & N1 + GROUND CIRCUIT BREAKER 120 VAC 15 AMPS CONTROL PANEL POWER MUST NOT BE RUN THROUGH SHUNT TRIP BREAKER ° m w w >J 0¢z Q 0~�
<br /> MANUAL ACTUATION DEVICE COVER N/A N/A N/A N/A IF SURFACE MOUNTED, USE COVER EXTENSION STI-6531B J m -F o a bi o a
<br /> WIRE FIRE SENSOR WHIIE WIRES BE PANEL TERMINALS EE ANII E3 — UDS APPLIANCE KILL SWITCH (OPTIONAL) KTS & N1 KTS & N1 120 VAC < 4 AMPS KILL SWITCH TERMINALS MUST BE IN SERIES WITH OTHER KILL SWITCHES O C o w>N U N o ow Z z~
<br /> 7 21 AND 24 WIRE FIRE SENSOR BLACK WIRE BETWEEN HOOD CORE PANEL TERMINALS 21 AND 24 7 U Q o o= z Q�z E Q W N
<br /> REMOTE FIRESTAT SENSOR(S) 22 AND 23 BLACK AND WHITE 24 VDC < 1,0 AMPS HIGH TEMP (842°F) #CW04427 (WHT) & #CW04427B (BLK)WIRE OR SIMILAR ONLY IF RAN OVER TOP 0 Q Z w o via-�Z o0 a o�o
<br /> OF Hnnni OTHERWISE BELDEN #622ouL OR SIMILAR PLENUM RATED WIRE' SEEREMOTE 120VAC ANSUL AUTOMAN (OPTIONAL) AU1, AU2 SOLENOID 120 VAC < 6 AMPS 120V TO AU1, AU2 TO ANSUL ELECTRIC AUTOMAN, ANSUL SOLENOID TO NEUTRAL o Z w w
<br /> 8 FIRE ALARM CONTACT AL1, AL2 VARIES 50V MAX UP TO 1 AMP FIRE ALARM RELAY CONTACTS FOR BUILDING FIRE ALARM LOCATED IN THE 8 LGV & N1D (IF 24 VDC) 24 VDC IF 24 VDC - 2 WIRES & GROUND, N1D TO RED, LGV TO RED, AND GREEN TO GROUND o 0 o m U)fy O O J a Q Z
<br /> (AC/DC) CORE ELECTRICAL CONTROL PANEL GAS VALVE RED/RED/GREEN < 1,0 AMPS c J o0 J 0?�<m UJ
<br /> GAS & N1 (IF 120 VAC) OR 120 VAC IF 120 VAC - 2 WIRES & GROUND GAS TO RED, N1 TO RED, AND GREEN TO GROUND
<br /> RS-485 COMMUNICATIONS CORE SYSTEM (1) ILA, TO CORE SYSTEM (2) ILA. CORE SYSTEM (1) ILB, TO CORE SYSTEM (2) ILI. m �I-Z U w o w
<br /> 9 CORE INTERLOCK(S) ILA, ILB, ILC ILA, ILB, ILC SIGNAL CORE SYSTEM (1) ILC, TO CORE SYSTEM (2) ILC. USE BELDEN# 88760 OR SIMILAR WIRE g L o w w N¢0 En O U)~
<br /> J W>� 0mLO LL
<br /> TROUBLE CONTACT TBC, TBL, TUK VARIES MAX 120 VAC UAMP� 6 WIRE TO TBL & TBC NORMALLY OPEN CONTACT, CLOSES IN TROUBLE CONDITION F— — — — — — — — — — — — — — -2 WIRESCONTROL P& GRO ND ANEL ER 2 w z 5 bi Ld o 0 Lo Z �z o
<br /> 10 10 —_— — — — -120 VAC, 15 AMP SERVICE LU Q of 0�vi J UJ a 3
<br /> CORE COMMUNICATIONS CABLE RJ-45 Jack INTERNET CONNECTION SIGNAL <1.0 AMPS TYPICAL CONNECTION CATS CABLE TO LOCAL AREA NETWORK VIA ETHERNET SWITCH OR -WIRE TO H1 AND N1, GROUND co W W ct mo o z W a-
<br /> WIRELESS ROUTER WITH VALID INTERNET CONNECTION -POWER MUST NOT ORIGINATE rn Z<=U V) 0 z cn z
<br /> 11 FIRE ALARM CONTACT 11 i iii I FROM SHUNT TRIP BREAKER � w v�O W w Q z= ccr)Ld=
<br /> W= J H
<br /> N �0_~UUH <FD OZ2
<br /> 0 Of
<br /> -2 WIRES WIRED TO NORMALLY — FIRE ALARM PANEL CORE INTERLOCK I I I • w�v Z zo o0 Z o 2Q w U
<br /> 12 OPEN CONTACTS (CLOSES IN -2 WIRES + SHIELD 12
<br /> FIRE CONDITION) _ _ -USE BELDEN#88760 OR SIMILAR WIRE rn w w o 0 J U)Q(w� =o
<br /> �f— _- - - - - _ _ Qo
<br /> -CORE CONTROL PANEL AL1 -SEE FIGURE 3
<br /> 13 ASEEND AL2
<br /> FGURE 2 III - - - - - - - - - - - - - - 13 IaidfE I < OfmZOfaw0�0= Z F_
<br /> o
<br /> U0Ld<>-PZZWOlnU)Hw
<br /> SHUNT TRIP BREAKER (OPTIONAL) ~
<br /> -2 WIRES, 120VAC ao z zo�z J o Z oz 0-Lw w
<br /> 14 TROUBLE CONTACT III�I -ST TO Al ON SHUNT BREAKER EXHAUST HOOD o J-U(n 0-J z Ei o n
<br /> -2 WIRES TO NORMALLY CORE COMMUNICATIONS CABLE 14 -NEUTRAL TO A2 ON SHUNT TRIP--\ GAS VALVE POWER d o 0 W o U of o J z w o Z
<br /> OPEN CONTACTS (CLOSE �II�I -CATS CABLE BREAKER -2 WIRES & GROUND v o >-z J w =� U)o
<br /> IN TROUBLE CONDITION) MUST BE INSTALLED TO A LOCAL AREA I -24 VDC WIRE TO LGV & N1D N W N a m Q z_w z m o =W UJo
<br /> 15 -CORE PANEL TERMINALS
<br /> 15 I I -120 VAC WIRE TO GAS &N1 O ao 0 0 0 0 W W c�o Q cn w
<br /> MANUAL NETWORK WITH VALID INTERNET ACCESS C z Q a Q= w Of 0
<br /> TBL AND TBC VIA ETHERNET SWITCH OR WIRELESS
<br /> -SEE FIGURE 4 ACDEVICE ROUTER w 0 0
<br /> W QI J W W 0 W
<br /> 1s SUPERVISED LOOP 10 TO 20 I is 36 INCHES CLEARANCE REQUIRED IN FRONT di ��m>U _ m IT �o 0-
<br /> -4 WIRES, 24VDC CONNECT BLACK FEET FROM OF ALL UTILITY CABINET DOORS z 0 0 N o Q I-~o r Q UNJ}
<br /> WIRES BETWEEN 21 AND 24 IN PANEL, EXHAUST HOOD HOOD LOCATED I THE PANEL SHALL ALSO BE LOCATED IN AN i O Z U 0 w�w�ow W o UJ �o J
<br /> 17 CONNECT WHITE (OR RED) WIRES NEAR POINT 17 ACCESSIBLE AREA WHERE THE AUDIBLE AND = Q �-0 Of R_ Lin
<br /> BETWEEN 22 AND 23 IN PANEL OF EGRESS Of 0 cn J R- w
<br /> -ADDITIONAL FIRESTATS WIRED IN I VISUAL ALARMS CAN BE HEARD AND SEEN _
<br /> 18 18 POWER TO ELECTRIC 00 W M J a W_J 0 z m l`
<br /> FROM HOOD w QwQma���cwicn °��cn
<br /> SUPERVISED LOOP I GAS VALVE oo J U} w Z 1n L`I LJ Z z
<br /> -USE HIGH TEMP (842°F) #CW04427 MANUAL ACTUATION DEVICE WIRES APPLIANCE rn Q Z w o W w N z Z Q z z
<br /> (WHT) & #CW04227B (BLK)WIRE ONLY -4 WIRES, 24VDC WIRE (TERMINAL 1) -STRAINER MUST BE
<br /> IF RAN OVER TOP OF HOOD; BETWEEN 102 AND 103 I INSTALLED UPSTREAM Q w Z Q W C3 z w= U v 0J
<br /> 0
<br /> pO�Q J
<br /> 19 OTHERWISE BELDEN #6320UL OR -WIRE (TERMINAL 2) BETWEEN 101 AND 104 1s OF VALVEU � w>?Q 0 W 00 N:U z o N
<br /> SIMILAR PLENUM RATED WIRE -ADDITIONAL PULL STATIONS WIRED IN Ld) > c�Z U w z-
<br /> U
<br /> -SEE FIGURE 1 SUPERVISED LOOP 0)
<br /> OR SIMILAR WIRE I m Q 0 0 Z wi=J LU o Q Q~
<br /> 20 -SEE FIGURE 2 20 � 0 J w N o Q Q w Z o w
<br /> 42 TO 48 INCHES — —
<br /> ELECTRIC GAS '_ a z W Can 0 _? 0 w
<br /> 21 36 INCHES CLEARANCE REQUIRED IN FRONT ABOVE FLOOR MANUAL ACTUATION DEVICE 21 > < o bi 0 R-Q U~ U
<br /> OF ALL UTILITY CABINET DOORS LEVEL TO Ft 0 U 0 Z U z LL w w J�
<br /> THE PANEL SHALL ALSO BE LOCATED IN AN ELECTRIC CENTER OF PUSH
<br /> PART #STI-SS2431 m 0 0 0 Z o o? 0 N w0
<br /> ACCESSIBLE AREA WHERE THE AUDIBLE AND GAS PROTECTIVE COVER MUST BE INSTALLED
<br /> 22 VISUAL ALARMS CAN BE HEARD AND SEEN STATION 22 cn Z J Q F-Q w 0 W W GO�z
<br /> ZOW 0U1 W Wpw= 0H-(L
<br /> 23 COOKING 23 Q CL l?o w Q w r 0�
<br /> > _J LLIL <<Ld 0ox� >w=
<br /> APPLIANCE(S) (n 0 Ch>�F U W"'�m
<br /> APPLIANCES) Wi zLL_ 0z L_old d a o Q biQ
<br /> 24 ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD 24
<br /> BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES NOTE: SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS z
<br /> NOTE: SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS CD
<br /> 0
<br /> N
<br /> A B C D E F G HI FACTORY WIRING JOB NO MODEL NUMBER nry_ DRAWN BY SCHEMATIC TYPE DESCRIPTION ❑F OPERATION: �)
<br /> SCHEMATIC Fire System #1 TANK FS - 4.0/4.0/4.0. Tank-based Fire Protection System equipped with Electronic Detection utilizing 00
<br /> 5 2 7 4 7 5 81pnpp CORE board as a Listed Release Mechanism, Installed in Hood Mounted Utility Cabinet separate from prewire. CV
<br /> GND GR ATTENTI❑N: L❑W-VOLTAGE DC OR SIGNALING WIRE SH❑ULD CORE FIRE JOB NAME DATE DWG NO Includes 12' box housing circuit board, batteries, and terminals for connection to main control panel. CN
<br /> PROTECTION DENNY'S - STOCKTON CA
<br /> 1 H11 BK" BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES, 1 Cq
<br /> 6AWGTANK PROTECTION LOW-VOLTAGE FIGURES 02/10/2021 Rev. 17
<br /> o PN1 1606-XLP-60EQ Q C7')
<br /> LN- Adjust power supply to 27.5 FS-1: MASTER RA-x RD-x 2 U
<br /> PSM-2 60W Volts with an accurate 120 VAC 24 VDC X
<br /> Digital Volt Meter or with an RELAY RELAY (i LL
<br /> HMI plugged Into the CORE NO 4 3 NO 4 3 F J-1: MASTER A.- >
<br /> +- board, NC 2 1 NC 2 1 3 rT1
<br /> 2 COIL 8 7 COIL 8 7
<br /> COM 6 5 COM 6 5 2 -0RD 18AWG BK 18AWG 6 Lo
<br /> settDIP SWE8 4 (D (-) LO
<br /> Switch
<br /> DIP J W I + c h to CLOSED COMPONENT LIST
<br /> PCB-2 position, Slave LABEL DESCRIPTION USE BELDEN #6320UL 04
<br /> 1 2 3 4 5 6 7 8 CORE with 5 OR SIMILAR WIRE �� ii
<br /> ALL 18AWC address 1 set MAD-01 MANUAL ACTIV4-ICN <1 Ln U
<br /> DIP SW 8 to DEVICE J2-1 J10-1 N
<br /> J3-1 J3-3 CLOSED FCB-2 CORE PCB• O O O • O O • PCBCORC ALL
<br /> 3 ,3 position, All FSM-2 CORE POLI- su��- e J2-2 J10-2 MICROSWITCH/
<br /> 3x HID RD J3-2 J3-4 BK N1D 3x • • setDIP3WS8 MANUAL
<br /> 1606-XC'-50L
<br /> ❑PEN \,/S-x water Solencld ACTUATION
<br /> OPEN. varies DEVICE L
<br /> RD BR Jumper if water valve LT-06 24V Red Ind. Light 7 FIRE Z F+1
<br /> J4-1 J3-8 PNL ll63 OUR CORE
<br /> supervision switch is used STAT-1 NO-WH BK-C 0-WH O
<br /> FIRE INDICATOR FAULT CONDITION FLASH CODES LL-01 Surf. Level Sensor �/� OR RD) BUILDING CONTROL
<br /> BK 2 Release Solenoid AQ5510 BREAK WIRE BK-C (OR RD) BREAK WIRE 1 2 FIRE ALARM FIREL 0J
<br /> J4-6 3 Pressure Switch A0-01 Audible Alar, 8 BEFORE BEFORE MANUAL ALARM
<br /> Se/Re et S
<br /> G -1 4 Auxiliary Fault INSERTING INSERTING ACTUATION CONTACT
<br /> 4 SW-05-2 PB-01 Prime/Reset switch INTO DEVICE
<br /> RD PK RD RD TERMINAL LGV USED FOR 24VDC 5 Microcontroller Fault D7 E2X11 INTO FIRE
<br /> 3 ® J4-13 J3-5 G POWERED GAS VALVES ONLY, 6 N/A s TERMINALS STAT-2 NO-WH TERMINALS BK-C �� 0-WH ® (__)
<br /> Test Armed 24V DC Gas Valve SW-0E TEST/ARM Switch
<br /> GAS VALVES SHOULD BE WIRED 7 Supervised Loop ZBSAD2 OR RD)
<br /> RD-17 TO MASTER CORE BOARD ONLY, 8 Ground Fault BK-C (OR RD)
<br /> RD BR sw-oa Tamper Switch 1 2 ALARM AL2 END EJ
<br /> I J3-11 9 Surfactant Low BZ-2Ru1-A2 OF �
<br /> INPUT
<br /> Fire RelayC _1 10 Battery Voltage Low SP-1 Surfactant Pump 10 LINE
<br /> PRW-05 YW BR S-IBL 11 AC Power Failure 50000-005 AL1 DEVICE
<br /> J3-7 3 GV-1 24v DC Gas Valve
<br /> 12 Door Tamper Switch J2-3 J10-3
<br /> Test Armed varies
<br /> RELEASE SOLENOID 13 Test Mode t9
<br /> LT-6W-05- FS-XX Duct Fire Sensor
<br /> 5RD BK J4-3 J3-10 P 4 R Hood t on l
<br /> Test Armed 15 FauLT-os 24v YLw Ina, Light J2-4 J10-4 I
<br /> FIRE IN ICATOR pA-01 16 Fault on PCU iIn Interlock Network n Interlock Network PNL-1163-OUY
<br /> RIS RD PS-01 Renote Puiu/Push WIRING CONNECTIONS FOR FIRE
<br /> 0o J4-2 J2-1 z1El Station STI-SS2431 12 WIRING CONNECTIONS ALARM CONTACT
<br /> HIGH TEMP WIRE cs4z F), WIRING CONNECTIONS
<br /> Audible Alarm PWS-01 Station
<br /> Polder OWER FOR FIRESTAT LOOP FIGURE 2
<br /> PN SLPCON-xFT required 24VDC 10w POWER FOR MANUAL ACTUATION LOOP
<br /> J2-2 BK FS-01 for all Supervised Loop RD-XX 24VDC Phoenix Relay FIGURE 1
<br /> FIGURE IA
<br /> wiring in contact with a PLC-RPT-24DC/21
<br /> p 1
<br /> FIRE STAT SUPERVISED LOOP K W hood. All other wiring
<br /> 13
<br /> RD B�OPK J4-8 May be mixed factory and field Fire Stat shall be PN 632CUL,
<br /> �j Prime / Reset wiring See Installation Schematic. Belden or similar. Factory LT-4
<br /> GY G WH PS Pressure Swtcr Z U
<br /> Multiple fire sensors possible, FS-02 mounted hood sensors will EWC-PR-SSURL
<br /> RS-1 be terminated at junction WASH I DICATOR 14 }+
<br /> WH R � J4-9 K W box on top of hood. -
<br /> J2-3 BK �3 Fire Stat H1 116AWG RD 116 RD 11 S-3 WH N1 BUILDING W 0 -1
<br /> Pressure Switch C NO 15 FIRE ALARM CORE
<br /> Hot Water Wash Solenoid CONTROL SUPERVISION SUPERVISION SUPERVISION
<br /> RD LEGEND
<br /> J2-4 FIELD WIRING PANEL SWITCH SWITCH SWITCH -
<br /> �4
<br /> FACTORY WIRING SHIELDED TWISTED PAIR TROUBLE CONTACT w
<br /> J10-1 RD 101 BK- BLACK YW- YELLOW 18 ILA BK BK LA L Q
<br /> Auxiliary Interlock (AUX-011e 0
<br /> 7 Wire AUl / AU2 of adjacent Master CORE BL- BLUE GY- GREY In
<br /> MS-01 paneKs) in each manual activation loop BR- BROWN PR- PURPLE DATE: 1 /17/2022
<br /> RD L
<br /> sw-off J10-2 BK 10� C N for simultaneous activation. RD- REL 17 RD RD TUK TBL ND NC 1 2 1 2
<br /> c Ho R J4-12 Micro SW WH- WHITE OR --PEEN L TROUBLE END
<br /> Door Tamper Switch MANUAL ACTUATION LOOP / REMOTE FIRE AUl/AU2 will have continuity for 10 DRY CONTACTS (SHOWN DE-ENGERGIZED) OR/BL- OR/BL STRIPE INPUT OF DWG.#:
<br /> SYSTEM LOOP. AUX-01 seconds if adjacent panel goes into fire RD-20-1 BL/RD- BL/RD STRIPE LINE U O
<br /> condition, activatingthis CORE Panel but TROUBLE RELAY. Contact terminals �.
<br /> J3-14 Multiple manual actuation possible. Ul A TBL RD/GN- RD/GN SIRIPL 18 TBC C C C 5274758
<br /> A Plug jumper with wires from pial to allowing for a reset after 10 seconds ` TBC & TBL make If there Is trouble, WH/BL- WH/BL STR.PE L � 4—
<br /> RD-19 pin4 and from pint to pin3 should be Ad,Jacent T 14c Contact terminals TBC & TOK make if E
<br /> (D
<br /> RDA RD/GN J4-5 mounted on J10 if there is no manual CORE NOTES AUl/AU2 terminals of CORE Panel 11 YW the system Is ok. WIRING CONNECTIONS
<br /> 8 Panel should not be wired into its own manual FOR CORE INTERLOCK
<br /> actuation device and no microswitch� JOB NAME
<br /> Equipment Rela activation loop RD-19-1 COOKING EQUIPMENT DISABLE RELAY, 19 DRAWN O
<br /> y MAD-01 FIGURE 3 D
<br /> RD-20 T For UDS Kill Switch, wire EKC and DENNY'S - STOCKY,,, BY: k C U r t I S N (�
<br /> RD OR/BL CzNO �� 12 DRAWING TITLE LLD
<br /> 1 J3-13 BK EKS terminals to like terminals In '^ >+
<br /> J10-3 103 UDS paneh DCV-2111 > 0)
<br /> Tro e elay Manual K 11 Yw WIRING CONNECTIONS FOR v!
<br /> ��`_1'� DESCRIPTION OF OPERATION 20 Q z O
<br /> RD 1 OR/BL J3-16 RD Actuation Fire System #1 TANK FS TROUBLE CONTACT SCALE: \ U Q N
<br /> J10-4 104 14 AWG RD-17-1 FIRE SYSTEM DRY CONTACTS, - 4.0/4,0/4.0, Tank-based FIGURE 4 �� �� > (� o
<br /> Auxiliary Interlock Relay CAT-5 WIRING (MASTER ONLY) ARS Fire Protection System
<br /> 12 Dry contacts will make C2 to AR2 3/4)) — 1 —0 U
<br /> J equipped with Electronic
<br /> 14c when system is armed. Detection utilizin CORE 21
<br /> FIELD WIRED IF REMOTE PREWIRE ECPM03 9 O
<br /> 9 11 YW board ns n Listed
<br /> J9 PUT END OF LINE PLUG IN EMPTY RJ45 Release Mechanism. MASTER DRAWING Y
<br /> Installed ouedIn Hood ^, U Z
<br /> AL1 UNLESS RrtELD,AIPRIU[]f$]F�W�F� TEI�VILNTIMfx6Q{�5. Mounted Utility Cabinet 22 W � }� Q
<br /> To Building Fire separate from prewire. 0
<br /> Alarm PanelIncludes 12' box housing 4- v
<br /> AL2 SHIELDED TWISTED PAIR circuit board, batteries, 0 (�
<br /> FIRE ALARM SYSTEM DRY CONTACTS BK BK and terminals for N
<br /> Ter ahs AL1 & AL2 make in FIRE, J7-2 CA RS-485 CORE INTERLOCK connection to ronin 23 Z
<br /> NETWORK, Connection to control panel, ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD J
<br /> other CORE Panels or J F F
<br /> + RD J1-1 J7-3 RD RD CB Communication Module. See BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES X U >
<br /> 5 AMP FUSE Installation Schematic for NOTE: SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS W a)
<br /> Q 24 VOLT BATTERY PACK Connection OB NO DRAWN BY 24 m w 0 4-
<br /> DRAWN J1 RD-18-1 0 = W a (n
<br /> FOR SHIPMENT + BK J1-2 J7-1 Shield CC INTERLOCK FOR ting 1N ACTIVATION. 527475$ N
<br /> �� Used for activating 120V automan TYPE DATE
<br /> 14or adjacent Master CORE panels FACTORY 1/17/2022 SHEET N O
<br /> 11 YW during active Fire Condition. DWG NO ECP #1-7 ■ SHEET NUMBER
<br /> 6 FS-8 . 5
<br /> DATE
<br /> October 13, 2021
<br />
|