My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
4747
>
1600 - Food Program
>
PR0160141
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2023 11:11:59 AM
Creation date
2/23/2023 4:43:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0160141
PE
1626
FACILITY_ID
FA0002608
FACILITY_NAME
DENNYS
STREET_NUMBER
4747
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
10816003
CURRENT_STATUS
01
SITE_LOCATION
4747 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
380
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> AIR BALANCE SCHEDULE CALCULATATION V <br /> PACKAGED ROOFTOP HEAT PUMP UNIT SCHEDULE UNIT OUTSIDE AIR RETURN AIR SUPPLY AIR EXHAUST AIR PRESSURE _ <br /> RTU-1 400 1600 2000 400 <br /> RTU-2 800 2200 3000 800 E <br /> EQ MAKE& NOMINAL COOLING CAPACITY <br /> HEATING HSPF/ EER/ WEIG RTU-3 800 2200 3000 800 = <br /> # MODEL TONS (BTUH) 0 <br /> MARK CAPACITY COP SUPPLY FAN POWER SUPPLY SEER/ HT UNIT DIMENSIONS(IN.) EF 1 110 110 <br /> (BTUH) IEER (LBS.) O Q � <br /> EF-2 300 -300 •� <br /> MAU-1 4685 4685 4685 <br /> (EQUIV. MCA/ R <br /> TH SH CFM HP VOLT PH HZ H W D KEF 1 2660 2660 <br /> ACCEPTABLE) MOCP = V <br /> KEF-2 2850 -2850 L •; <br /> DWEF-1 660 -660 <br /> TRANERTU- 1 5 60,000 42,000 59,000 8.2/- 2,000 1 208 3 60 31 /45 12.3/14.3 966 40-7/8 53-1/4 88-5/8 TOTAL 6685 6000 12685 6580 105 c C <br /> WSC06SC060 /- = 0 M <br /> O �C <br /> 11.3/ / Room AREA OSA REQUIRED EXHAUST REQUIRED •- r.j <br /> TRANE <br /> RTU- 2 7.5 93,000 65,100 88,000 -/3.4 3,000 1 208 3 60 44/60 1113 46-7/8 53-1/4 88-5/8 AREA(S.F.) RATE(CFM/SF) REQUIRED CFM RATE(CFM/SF) REQUIRED CFM PROVIDED CFM = bb CU <br /> WSC092 12.4 C 4-0 <br /> ENTRY 491 0.5 245.5 0.00 0 0 a-+ lG <br /> TRANE <br /> WOMEN'S RESTROOM 161 0 0 70/WC,URL 140 150 � � <br /> M <br /> 11.3/-/ � 0 <br /> RTU- 3 WSC092 7.5 93,000 65,100 88,000 -/3.4 3,000 1 208 3 60 44/60 12 4 1113 46-7/8 53-1/4 88-5/8 MEN'S RESTROOM 127 0 0 70/WC,URL 140 150 Q �p <br /> STORANGE 424 0 0 0.00 0 0 0 �p <br /> NOTES: DINING ROOM 1809 0.5 904.5 0.00 0 0V V a M <br /> SERVICE AREA 519 0.15 77.85 0.00 0 0 <br /> 1 INSTALL WITH DISCONNECT SWITCH AND ALL WEATHERPROOF GFCI. COOKLINE 268 0.15 40.2 0.00 0 0 V •� <br /> 2 THERMOSTATS INSTALLED AT 48"AFF W/REMOTE SENSORS. SCULLERY 411 0.15 61.65 0.00 0 0 i M <br /> PREP AREA 217 0.15 32.55 0.00 0 0 d1 m <br /> PROVIDE STANDARD THROWAWAY CONSTRUCTION FILTERS OF MERV 13. MECHANICAL CONTRACTOR SHALL FURNISH AND FIELD INSTALL NEW FILTER PRIOR TO 0 O <br /> 3 BUILDING OCCUPANCY(INCLUDING FOR INTERNAL PRESSURE DROP. MECHANICAL ROOM 109 0 0 0.00 0 0 Q •� N c <br /> OFFICE 81 0.15 12.15 0.00 0 0 � Ln 0 <br /> 4 EXTEND CONDENSATE DRAIN DIRECTLY TO A LOCAL CODE APPROVED RECEPTOR. EMPLOYEE ROOM 52 0.15 7.8 0.00 0 0 a 0 t <br /> 5 PROVIDE REMOTE ALARM INDICATORS FOR THE SUPPLY AIR SMOKE DETECTORS CLEARLY LABELED AS TO FUNCTION AND UNIT SERVED. <br /> RESTROOM 22 0 0 70/WC,URL 70 110 NJ rl d <br /> DUCT SMOKE DETECTORS SHALL BE PROVIDED FOR SYSTEMS HAVING A GREATER THAN 2,000 CFM CAPACITY ON SUPPLY PLENUM. KEYED REMOTE TEST SWITCHES W.L000LER 1 126 1 0 0 0.00 0 1 0 <br /> 6 WITH LED LIGHT INDICATOR ARE TO BE PROVIDED ON THE WALL AT NO GREATER THAN 6 FEET FOR ALL DUCT DETECTORS. DUCT DETECTOR ACTIVATION SHALL W.I.FREEZER 103 0 0 0.00 0 0 <br /> RESULT IN COMPLETE SHUT DOWN OF HVAC UNITS AND NOTIFICATION TO THE FIRE ALARM SYSTEM IN THE FORM OF A SUPERVISORY SIGNAL. TOTAL REQUIRED: 1382.2 <br /> PROVIDE AN INTEGRATED ECONOMIZER WITH FAULT DETECTION DIAGNOSTICS(FDD)FOR EACH INDIVIDUAL COOLING SPACE CONDITIONING SYSTEM THAT HAS A TOTAL PROVIDED: 6685 <br /> 7 TOTAL COOLING CAPACITY OVER 54,000 BTU/HR. <br /> SOH <br /> KITCHEN EXHAUST FAN/MAKE-UP AIR SCHEDULE <br /> J M 4091 � <br /> * EXP <br /> EQ MA SP. MOTOR SONES WT MANUFACTURER& J' Q <br /> # RK EQUIP. CFM (W G) RPM HP FLA (ELEC) (DB) (LBS) MODEL NO. REMARKS �,� C P <br /> For CAI�� <br /> KEF- 1 KITCHEN HOOD EXH 2,660 1.15 1,166 3.0 9.5 208/3 14.5 183 CAPTIVEAIRE 1,2,4 <br /> FAN DU180HFA <br /> KEF- 2 KITCHEN HOOD EXH 2,850 1.15 1,199 3.0 9.5 208/3 17.1 183 CAPTIVEAIRE 1,2,4 <br /> FAN DU180HFA <br /> DWEF- 1 DISHWASHER HOOD 660 0.5 1,310 0.333 1.9 208/1 11.7 67 CAPTIVEAIRE 1,2,4 <br /> EXH FAN DU33H <br /> MAU- 1 KITCHEN MAKE-UP 4,685 0.5 1,709 5.0 15.0 208/3 23 692 CAPTIVEAIRE 1,3,4 <br /> AIR A2-20D <br /> REMARKS: <br /> 1 EQUIVALENT ACCEPTABLE. <br /> 2 KITCHEN HOOD EXHAUST FAN; HOOD CONTRUCTION:430SS. <br /> 3 PROVIDE ROOF CURB AND ROOF JACK AS REQUIRED. <br /> 4 INTERLOCK EXHAUST FAN AND MAKE-UP FAN AIR FAN WITH HOOD CONTROL AND EMERGENCY SHUT-OFF. EXHAUST&MAKE-UP AIR <br /> SYSTEMS ARE ELECTRICALLY INTERLOCKED WITH ONE ELECTRIC SWITCH. <br /> 71 <br /> FAN SCHEDULE <br /> EQ SP. MOTOR SONES WT MANUFACTURER& <br /> #5 MARK EQUIP. CFM (W G) RPM HP FLA (ELEC) (DB) (LBS) MODEL NO.EQ <br /> EF- 1 RESTROOM EXH 110 0.1" 7.7W 0.1 120/1 0.3 12.3 BROAN XB110 1,2,3 <br /> FAN <br /> EF- 2 RESTROOM EXH 150 0.1" 42.8W 0.1 120/1 1.4 13.1 BROAN QTXE150 1,2,3 <br /> FAN <br /> REMARKS: <br /> ti <br /> 1 EQUIVALENT ACCEPTABLE. C) <br /> J N <br /> 2 INSTALL WITH BACK DRAFT DAMPER. <br /> ui <br /> 3 ELECTRICALLY INTERLOCKED WITH LIGHT SWITCH WITH MANUAL OVER-RIDE SWITCH. Q Q <br /> TYPEO z <br /> # AIR DEVICE SCHEDULE � <br /> MARK FACE SIZE TYPE MOUNTING DIRECTION MANUF. NOTES W W ILL <br /> TYPES-1 24X24 SUPPLY <br /> SURFACE/ 4-WAY TITUS 1 2 3 4 J <br /> LAY-IN (OR EQUIV.) U <br /> f <br /> SURFACE/ TITUS 1 2 3 4 v/ <br /> S-2 12X12 SUPPLY LAY-IN 4-WAY (OR EQUIV.) <br /> UD <br /> R-1 24x24 RETURN SURFACE/ 1-WAY TITUS 1,2,3 Q <br /> LAY-IN (OR EQUIV.) z 0- Y <br /> OTES: z O <br /> 1. PROVIDE NECESSARY MOUNTING HARDWARE AND ACCESSORIES AS w <br /> REQUIRED. Q <br /> .ALL AIR DEVICES SHALL HAVE MANUFACTURER-APPLIED STANDARD WHITE <br /> INISH UNLESS NOTED OTHERWISE. REFER TO ARCHITECTURAL DRAWINGS FOR <br /> CP COORDINATION. <br /> 3.AIR DEVICE SHALL BE OF STEEL CONSTRUCTION. <br /> 4.AIR DEVICE SHALL BE INSTALLED COMPLETE WITH MANUFACTURER AVAILABLE <br /> MOLDED INSULATION BACKING. FIELD-FABRICATED INSULATION BACKING IS NOT <br /> FLLOWED UNLESS FIRST APPROVED BY THE OWNER'S CONSTRUCTION <br /> NAGER. <br /> Z <br /> O <br /> W <br /> Lu <br /> a a a a a a <br /> DATE: SCALE: <br /> 5/09/2022 <br /> SHEET TITLE: <br /> MECHANICAL <br /> SCHEDULES <br /> M001 <br /> PLOT DATE: 5/23/2022 6:15:11 PM <br />
The URL can be used to link to this page
Your browser does not support the video tag.