Laserfiche WebLink
Iii <br /> E <br /> = O <br /> 0 Q bo <br /> R <br /> :cu <br /> 16"O 16"Q) ® 150 i u <br /> 19 <br /> 1 <br /> R- 1 R- 1 Q 1 3 •i <br /> 1100 1100 O = G 1> m <br /> O -td6„0 •� rl -0 <br /> Q 18"x20" Q = bD cu <br /> S - 1 S - 1 <br /> 150 <br /> :3 Ln l0 <br /> kD <br /> P� 6„ O 0 3 <br /> S - 1 i � a <br /> S - 1 <br /> * 100 200 Vs -�d <br /> S - 1 <br /> 12" O12"0 450 R 6"0 8 co <br /> 0 O <br /> ('S - 1 75 <br /> 450Ln 0 <br /> •� � t <br /> 77�sl14"0 � W r-4 0. <br /> 8"0 El <br /> 1 S - 1 <br /> O 2 <br /> 0 150 <br /> T14 014"0 S 1 -6"0 6"0 Mfg Us/o <br /> O O S2 -10"o 16"06"0 o �H CyF�Fyc� <br /> 14"0 20"0 C ?, <br /> O 20"0 J M 4091 <br /> 2, S- 11) 1 ® ® S- 1 yt�EXPc P � <br /> 18'y2,1" O T1 150 150 �TFOF CA��E�� <br /> RTU S <br /> Z 9lu <br /> 12" 12"0C) A 450 <br /> 0.. IL WE <br /> O 1 <br /> (4590 14"0 <br /> IO 18"0 O <br /> 7 <br /> RU 776CFM X18 QS K ^ 785CFM MAU <br /> o E� <br /> T2 s~� <br /> 1 m mm m <br /> O 16'0 O T3 <br /> 2 <br /> - 1 14"0 18" S- 22"0 24"0 <br /> 00 20 <br /> 8"0 <br /> KEF <br /> �� <br /> 1 S- <br /> O 8"0 10"0 20 <br /> 8"0 <br /> O O <br /> 1 1 12"0 <br /> S - 1 <br /> 450u uQ O 0 c O O O c 8 <br /> O S - <br /> �„(p) 7 200 <br /> 450 Q Q Q O <br /> 0 <br /> O c J 18°X20" 0 KEYED PLAN NOTES: <br /> CD <br /> 0 <br /> 1. INSTALL DUCT SMOKE DETECTOR ON SUPPLY SIDE PLENUM. J N <br /> O w <br /> S - 1 2. INSTALL PROGRAMMABLE THERMOSTAT 48"AFF AND MOUNT REMOTE <br /> 375 SENSORS HIGH ON WALL. Q Q <br /> O O 7 S - 1 S - 1 S - 1 3. EXHAUST TERMINATES ON ROOF. EXHAUST SHALL TERMINATE NOT LESS <br /> O Z <br /> THAN 3 FEET FROM A PROPERTY LINE, 10 FEET FROM A FORCED AIR INLET, O <br /> 8"0 CJ 375 O 375 O 375 ® AND 3 FEET FROM OPENINGS INTO THE BUILDING. Lu LL <br /> J <br /> 10' 10" 10" 10" 4. TYPE 1 HOOD; KITCHEN HOOD MUST OVERHANG MIN. 6" FROM EDGES OF Q U <br /> M <br /> KITCHEN EQUIPMENT BELOW. MAINTAIN GREASE DUCT SLOPE OF MIN 2%. U <br /> O � LL Z <br /> 5. INSTALL AIR CURTAIN AT DELIVERY DOOR.THE AIR CURTAIN SHALL PROVIDE >- U O <br /> Q ADOWNWARD-OUTWARD FLOW NOT LESS THAN 8" WIDE NOZZLE AND AN <br /> Q 16 O AIRFLOW NOT LESS THAN 1600 FPM ACROSS THE ENTIRE OPENING AT A 7 < Y <br /> POINT MEASURED 3' ABOVE THE FLOOR. THE AIR CURTAIN MUST BE ON L <br /> EF O O 1R100 AUTOMATICALLY WHEN THE DOOR IS OPENED. Z O <br /> 2 <br /> b"0 110-11 <br /> OO 0 6. 8" EXHAUST DUCT TO ROOF. W (n <br /> 6"0 O O O O C)6 3 S -2 8„� 7. RTU DUCTS FROM ROOF. SEE M101 FOR CONTINUATION. <br /> Co 100 S - 1 <br /> � �Cc�� ��S\ <br /> 100 0” 10"0 10"0 10"0 16"0 S3 <br /> Q1 1 1 CQ 2 <br /> *.S - _ 1 <br /> 375 75 75 375 <br /> Q <br /> z <br /> O <br /> 3 EF 6"0 <br /> 2 S - 2 w <br /> 100 <br /> Q <br /> <11<11<1 <br /> a a a <br /> DATE: SCALE: <br /> 5/09/2022 1/4" = 11-0" <br /> SHEET TITLE: <br /> GENERAL NOTES: <br /> MECHANICAL <br /> 1. IF DRAWINGS ARE INCORRECT FROM THE ACTUAL SITE CONDITION, <br /> CONTRACTOR SHALL NOTIFY ENGINEER(S) AND PROVIDE INFORMATION PLAN <br /> REFLECTING ACTUAL CONDITIONS. <br /> MECHANICAL PLAN mloo <br /> PLOT DATE: 5/20/2022 3:48:54 PM <br />