Laserfiche WebLink
• <br /> E <br /> V <br /> HANG PIPE LARGER THAN 4" STEEL STRUCTURE SECTION PLUMBING FIXTURE SCHEDULE a aA <br /> WOOD STRUCTURE <br /> * U <br /> 0 W <br /> FROM TOP OF JOISTS ONLY AT � .W <br /> � MARK ITEM HW CW VENT WASTE DESCRIPTION � <br /> PANEL POINT = � � <br /> SIDE BEAM CONNECTOR ALL-THREAD ROD HANGER ROD <br /> PIPE INSULATION AMERICAN STANDARD CADET PRO ELONGATED ADA COMPLIANT TANK WATER •5 <br /> ATTACHED TO TOP CHORD OF PROVIDE COPPER COATED INSULATION SHALL BE RUN WC TANK TYPE WATER CLOSET - 3/4" 2" 4" CLOSET WITH OPEN FRONT ELONGATED TOILET SEAT. 1.28 GPF. EQUIVALENT i <br /> ACCEPTABLE. <br /> WOOD TRUSS HANGERS WHERE CONTINUOUS THRU HANGERS <br /> ADJUSTABLE BAND HANGER HANGERS CONTACT BARE C � <br /> PPER PIPE PIPE AMERICAN STANDARD 0356.421 W/FAUCET AMERICAN STANDARD 6055.165. •� <br /> FOR PIPE 3-1/2"AND SMALLER rl <br /> AND CAST IRON PIPE 2"AND INSULATION PROTECTION SHIELD. USE 16 GAUGE LAV WALL MOUNTED LAVATORY 1/2" 1/2" 1-1/4" 1-1/4" SELECTRONIC PROXIMITY FAUCET.0.5 GPM.ADA COMPLIANT.EQUIVALENT = MO <br /> SMALLER PROVIDE GALV.STEEL SHIELD FOR ALL SHEET STEEL,2 PIPE DIAMETERS LONG, 120 ACCEPTABLE. INSTALL WITH POWERS#LFG480 MIXING VALVE(ASSE 1070 0C <br /> INSULATED PIPE.VERIFY INSULATION THICKNESS DEGREES SUPPORT, OR GRINNEL FIGURE 167. LISTED). i :+ <br /> WHEN SIZING HANGERS AND SHIELDS. O N <br /> N <br /> C <br /> Z PROVIDE UPPER ATTACHMENT AS REQUIRED FOR CASES NOT SHOWN HERE. ZURN Z-1902, 12"SQUARE TOP, HALF GRATE COVER AND 8"DEEP DOME <br /> FS FLOOR SINK 2" 2" <br /> DO NOT INSTALL HANGER INSIDE INSULATION OR OTHERWISE PENETRATE <br /> GAS PIPE SUPPORT STRAIER. EQUIVALENT FIXTURE ACCEPTABLE. Q tD <br /> wQ VAPOR BARRIER. DO NOT HANG ONE PIPE FROM ANOTHER EXCEPT IN CHASES. R V M <br /> as NOMINAL SIZE OF SPACING <br /> LU am SLOPE ALL WATER PIPING SLIGHTLY TOWARD DRAINABLE LOCATIONS. HANGER STEEL PIPE, SPACING OF TUBING OF ZURN Z1441 WALL CLEANOUT W/SMOOTH ACCESS COVER. EQUIVALENT L <br /> N IY SPACING FOR PIPE SIZES:AS INDICATED IN TABLE. CAST IRON: 10'AND WITHIN NOMINAL SIZE OF SUPPORTS WCO WALL CLEANOUT - - LINE SIZE •� W GJ <br /> � ww SMOOTH-WALL SUPPORTS( FIXTURE ACCEPTABLE. <br /> 0-0 V-0"OF ALL JOINTS. ROD SIZES FOR PIPE SIZE: 1/2"TO 4"=3/8",5"TO 8"= 1/2", PIPE(INCHES) (FEET) V ._ <br /> LU 0-Z (INCHES O.D.) FEET) L M Ol <br /> a 0= 10"TO 12"=5/8". LOCATE HANGERS WITHIN V-0"OF VALVES AND FITTINGS. m <br /> PROVIDE SUPPLEMENTAL STEEL STRUTS BETWEEN JOISTS IF REQUIRED. 1/2 6 1/2 4 FCO FLOOR CLEANOUT - -- - LINE SIZE ZURN Z1400-B FLOOR CLEANOUT EQUIVALENT FIXTURE ACCEPTABLE. <br /> WATER PIPE 1/2" 6' LOCATE HANGERS WITHIN V-0"OF EQUIPMENT CONNECTIONS. ANCHOR WATER C C <br /> 31" 6' PIPE AGAINST SWAYING DUE TO CHANGES IN WATER VELOCITY.CHAINS AND 3/4 OR 1 8 5/8 OR 3/4 6 Ln <br /> SUPPORT: •dA L1'1 O <br /> 1" 6' ZURN 24156 W/SEDIMENT BUCKET.TRAP PRIMER CONNECTION WHERE <br /> PERFORATED STRAP IRON AND STEEL ARE NOT ACCEPTABLE. DO NOT 1-1/4 OR LARGER 7/8 OR 1 FD FLOOR DRAIN - -- 2" 2"10 LJJ W 111 <br /> 1-1/4" 6' <br /> SUSPEND PIPE FROM JOIST BRACING MEMBERS. REFER TO CODES AND (HORIZONTAL) (HORIZONTAL) 8 REQUIRED BY CODE. EQUIVALENT FIXTURE ACCEPTABLE. <br /> 1-1/2" 6' SPECIFICATIONS FOR FURTHER INFORMATION. PROVIDE SEISMIC BRACING AS <br /> 2" 10' EVERY <br /> REQUIRED BY LOCAL AUTHORITIES. PROVIDE FIBERGLASS INSULATION WITH 1-1/4 OR LARGER EVERY FLOOR 1 OR LARGER CUSTOM STAINLESS STEEL 3 COMPARTMENT SINK. INSTALL W/T&S BRASS <br /> 2-1/2" 10' FLOOR <br /> ALL-SERVICE JACKET WITH VAPOR BARRIER ON ALL SIZES OF HOT AND COLD (VERTICAL LEVEL (VERTICAL) 3 <br /> 3" 10' WATER AND CONDENSATE PIPING. GAS PIPING SHALL BE KEPT A MIN.OF 6" LEVEL COMP 3 COMPARTMENT SINK 1/2" 1/2" 2" 2" B-0133-01 BACKSPLASH PRE-RINSE FAUCET AND 0231 ADD-ON FAUCET. 1.15 GPM <br /> 4" 10' ABOVE GRADE OR STRUCTURE. SPRAY VALVE. EQUIVALENT FIXTURE ACCEPTABLE. <br /> QROFESS/pN <br /> PIPE HANGER DETAIL (BELOW ROOF) SCALE <br /> HN N.T.S 1 MOP MOP SINK 1/2" 1/2" 2" 3" JOSERVIICOEFAUC TWITHHOINTEGGRALVACUUMBR AMOP SINK. INSTALLIKERSPOUT. EQUIVALENTT&S BRASSPT � J�GSUN -c; <br /> FIXTURE ACCEPTABLE. c) M 37036 G m <br /> 2"VENT 2"VENT a-, Exp. 9-30-22 <br /> --r\,!- CUSTOM STAINLESS STEEL WALL MOUNTED HAND SINK.4"O.C. T&S BRASS <br /> HS HAND SINK 1/2" 1/2" 2" 2" B-1110 SPLASH MOUNTED GOOSENECK FAUCET. EQUIVALENT FIXTURE * MECHANIC \* <br /> I I I ELMDOR/STONEMAN, MODEL ACCEPTABLE. �9TFOFC <br /> I I I #1100-4 SEALANT SHALL BE <br /> I I I APPLIED AROUND PIPE OPENING PREP PREP SINK 1/2" 1/2" - INDIR. CUSTOM STAINLESS STEEL PREP SINK. INSTALL W/T&S BRASS B-0231 FAUCET. <br /> I I I 1.5GPM. EQUIVALENT FIXTURE ACCEPTABLE. <br /> I I I THRU COUNTER FLASHING PIPE THRU ROOF <br /> I I I 3-COMP SINK SLEEVE FOR WATER TIGHT SEAL <br /> DROP-IN DROP-IN SINK 1/2" 1/2" - INDIR. CUSTOM STAINLESS STEEL DROP IN SINK.4"O.C. T&S BRASS B 1110 SPLASH <br /> INSTALL(3) MOUNTED GOOSENECK FAUCET. EQUIVALENT FIXTURE ACCEPTABLE. <br /> I I I APPLY PERMASEAL WATER VANDAL-PROOF <br /> PROOFING COMPOUND SETSCREWS CUSTOM STAINLESS STEEL PRE-RINSE SINK.T&S BRASS B-0133-B BACKSPLASH <br /> I I I AROUND PIPE, COUNTER PRE-RINSE PRE-RINSE SINK 1/2" 1/2" - - PRE-RINSE FAUCET. 1.15 GPM SPRAY VALVE. EQUIVALENT FIXTURE <br /> I I I FLOOR SURFACE FLASHING SLEEVE& ZACCEPTABLE. <br /> I I I SLOPED 1:50 TO THE FLASHING FOR WATER <br /> I I I FLOOR DRAIN ON TIGHT SEAL. WATTS SERIES LF15M2 WATER HAMMER ARRESTOR. INSTALLED PER <br /> I I I ALL SIDES OF DRAIN 2"MIN. WHA WATER HAMMER ARRESTOR - LINE SIZE - - MANUFACTURER'S INSTRUCTIONS. EQUIVALENT ACCEPTABLE. <br /> I .1U jj <br /> I I SEAMLESS LEAD FLASHING <br /> I ITRAP PRIMER INLET OVER STEEL REINFORCED BOOT 12"MIN. EXISTING GAS STORAGE EXISTING STATE INDUSTRIES SBD100 199NET GAS TANK TYPE WATER HEATER. <br /> SANITARY SEWER LINE <br /> BOOT HEIGHT 8"MIN. (E)WH WATER HEATER 1-1/2" 1-1/2" - - 100 GAL. 199,000 BTUH INPUT. EQUIVALENT FIXTURE ACCEPTABLE. <br /> BUILT-UP ROOFING 5"MIN. <br /> POT SINK,SCULLERY SINKS, DISHWASHING SINKS, COMMERCIAL <br /> DISHWASHING MACHINES AND OTHER SIMILAR FIXTURES SHALL BE <br /> CONNECTED DIRECTLY TO SEWER LINE. A FLOOR DRAIN SHALL BE <br /> PROVIDED ADJACENT TO THE SINK. THE FIXTURE SHALL BE LOCATED AT Ll <br /> THE SEWER SIDE OF FLOOR DRAIN THERE AN SHALL BE NO OTHER <br /> FIXTURES BETWEEN THEM PER CPC SECTION 704.3. <br /> 3 COMPARTMENT SINK DETAIL SCALE <br /> N.T.S 2 PIPING THRU ROOF DETAIL SCALE N.T.S 3 <br /> NEAREST COLD <br /> WATER SOURCE <br /> TRAP PRIMER VALVE <br /> SHUT-OFF VALVE SEE PLAN OR RISER <br /> FOR SIZE <br /> DISTRIBUTION UNIT <br /> GAS SOLENOID VALVE AND BY-PASS BYPASS PIPING ES-LF15M2 <br /> INTERCONNECT W/HOOD EXHAUST FANS IF REQUIREDApplications Sizing and Placement Fixture Units Sizing Information <br /> f1/2"CONTINUOUS SOFT FURNISHED BY HOOD SUPPLIER, <br /> COPPER TUBING,TYP. INSTALLED BY PLUMBING CONTRACTOR. <br /> (NO JOINTS) Water Hammer Arrestor Job Name_ Contractor � TYPEOF SUPPLY PUBLIC PRIVATE <br /> FIXTURE CONTROL W <br /> Job Location Approval �-Riser Typical Branch Line � Water Closet 1.66 PF Flush Valve 8 8 - 5 5 - <br /> SLEEVE AND FINISHED FLOOR Water Closet 1.66 PF Flush Tank 5 5 - 2.5 2.5 - Q <br /> SEAL PIPING Engineer Contractor's P.O.No. ���� ������ Pedestal Urinal 1.06 PF Flush Valve 4 4 - - - - <br /> THRU SLAB(TYP.) FLOOR DRAIN Stall or Wall Urinal Flush Valve 1.06 PF 4 4 - - - - O <br /> TO EQUIPMENT Approval Representative Stall or Wall Urinal Rush Tank 1.06 PF 2 2 - - - - <br /> ❑ ❑ ° ° Q As shown,it has been established that the preferred location Lavatory Faucet 2 11/2 11h 1 1 1 <br /> a° a OR MANIFOLD for the water hammer arrestor is at the end of the branch line I` <br /> Bathtub Faucet 4 2 3 2 1 h 1/2 <br /> FURNISH AND INSTALL A 1/4 TURN �i _ between the last two fixtures served. � <br /> MANUAL SHUTOFF VALVE IN AN The location of the water hammer arrestor shown above applies Shower Head Mixing Valve 4 2 3 2 1 2 N <br /> to branch lines that do not exceed 20 ft. 6m in length,from the Bathroom Group Flush Valve Closet - - - 8 8 3 <br /> TO OTHER ACCESSIBLE LOCATION ORAS ( ) g Bathroom Group Flush Tank Closet - - - 6 6 3 �•�••� w N <br /> FLOOR DRAINS TRAP PRIMER CONNECTION REQUIRED BY CODE. start of the horizontal branch line to the last fixture supply on this Separate Shower Mixing Valve - - - 2 1 2 > <br /> (TYPICAL) Series LF 1 SM2 _„ � branch line.When the branch line exceeds the 20 ft.(6m)length, Service Sink Faucet 3 3 3 - - - Q Q <br /> an additional water hammer arrestor should be used.This prac- Laundry Tubs(1-3) Faucet - - - 3 3 3 <br /> ALTERNATE: Water Hammer Arrestors tice is best defined by two rules which have been established to r ) U U <br /> CONNECT <br /> IF D AIN BODY cover the placement of water hammer arrestors. <br /> - - - �,/J z <br /> Combination Fixture Faucet <br /> HER <br /> LL <br /> TRAP Sizes: 1/2" - 1 <br /> DOES NOT HAVE A TRAP SANITARY LINE Up to 20 ft.(6m) Dimensions-Weight r <br /> PRIMER CONNECTION. What Is Water Hammer? X U O <br /> The noise from banging pipes is caused by shocks of high speed Rule 1 z <br /> SCALE SCALE water flowing in the piping system when a fixture is suddenly <br /> TRAP PRIMER DETAIL N.T.S 4 AUTOMATIC GAS SOV N.T.S 5 closed.Sudden stoppage of the water(a non-compressible liquid) z U <br /> Over 20 ft.(6m) <br /> flowing at a given pressure and velocity causes a surge or spike of y X ; W � lO <br /> water and is called water hammer.When this occurs,a pressure A <br /> wave travels back through the piping until it finds a point of relief. Rule 2 <br /> The LF15M2 and LF15M2S Water Hammer Arrestors are designed Q (f� <br /> PROVIDE SCREWED WASTE OR to eliminate this effect.The LF15M2 and LF15M2S features Lead Rule 1 covers multiple fixture branch lines which do not exceed <br /> COUNTER-SINK BRONZE VENT TO Free"construction to comply with Lead Free`requirements. a 20 ft.(6m)in length. <br /> PLUG FOR CLEANOUT TEE ABOVE Dishwashers,clothes washers,fast closing positive shutoff valves Explanation-Fixture-unit sizing and selection table is used to SIZE DIMENSIONS WEIGHT <br /> WITH TAPPED THREAD& incorporated in the system all contribute to creating water shock select the required PDI unit(water hammer arrestor). A B <br /> TEE JOINT COMPOUND PLUMBING WALL OR which is not only annoying but damaging to pipes and appliances. LF15M2 LF15M2S Rule 2 covers multiple fixture branch lines which do exceed in. mm in. mm lbs. kgs <br /> The Watts Series LF15M2 and LF15M2S incorporates a pre- 20 ft.(6m)in length. Threaded <br /> COLUMN REFER TO charged,permanent sealed air chamber to absorb the shock.The Pressure-Temperature <br /> INSTALL ESCUTCHEON FLOOR PLANS sealed chamber prevents the loss of air to the water and assures Explanation-Fixture-unit sizing and selection table T used to 1/2" LF15M2-A 13/8 28.5 515/6 150.9 0.5 0.2 <br /> PLATE AT CLEANOUT TEE. long and trouble-free life. Operating Pressure: Designed to operate on all domestic and select the required PDI unit(water hammer arrestor).The sum 3/4" LF15M2-B 13/e 34.9 89/,s 218.0 0.9 0.4 <br /> PROVIDE commercial lines @ 150psi(10.6 bar)working pressure. of the fixture units rating of units X and Y shall be equal to or 1" LF15M2-C 15/6 41.3 813/16 223.5 1.3 0.6 <br /> CONCRETE FLR. WATERPROOFING Features Temperature Range: 33°F to 180°F(0.5°C to 82°C). greater than the demand of the branches. 1" LF15M2-D 2% 54.0 915/16 252.5 2.0 0.9 <br /> •NPT solid hex brass adapter or solder end connection 1" LF15M2 E 2Ye 54.0 12'1/,6 322.5 2.3 1.1 <br /> p Materials Sizing and Selection Table 1" LF151V2-F 2% 66.7 115/32 283.5 2.7 1.2 <br /> ° for easy installation Z <br /> •Approved for installation with no access panel required Body: Copper ORDER ORDER '' A 1/2Solder p LF15M2-AS 1" 1/8 28.5 81/4 210.0 0.44 0.2 <br /> RISER LENGTH AS REQUIRED Piston: PolypropyleneMODEL „ " „ „•, (n <br /> •May be installed in new or existing plumbing systems with a 3/4" LF15M2-BS 11/8 28.5 10 254.0 0.54 0.2 <br /> Threaded Adapter: Lead Free`Brass in. Threaded solder > <br /> DIRECTION standard pipe tee vertically,horizontally or at any angle 1" LF15M2-CS 13/8 34.9 121/2 317.5 0.92 0.4 Lu <br /> O-rin EPDM /z" LF15M2-A 0750160 LF15M2-AS 0750150 1-11 A � <br /> LONG SWEEP AT OF •PDI Listed(PDI WH2O1) g 3/4' LF15M2-B 0750161 LF15M2-BS 0750151 12-32 B 1" LF15M2-DS 21/8 54.0 11 280.0 1.63 0.7 <br /> END OF LINE OR •Maintenance free-piston is the only moving part 1" LF15M2-C 0750162 LF15M2-CS 0750152 33-60 C 1" LF151VI2-ES 21/8 54.0 131/2 343.0 1.98 0.9 <br /> COMBINATION WYE •Air pre-load is 60psi(4.2 bar) 1" LF15M2-D 0750163 LF15M2-DS 0750153 61-113 D 1" LF151VI2-FS 21/8 54.0 16 406.5 2.32 1.1 <br /> AND EIGHTH BEND The information contained herein is not intended to replace the full 1" LF15M2-E 0750164 LF15M2-ES 0750154 114-154 E <br /> •Factory air charged and permanently sealed product installation and safety information available or the experience V LF15M2-F 0750165 LF15M2-FS 0750155 155-330 F <br /> IN RUN OF LINE. of a trained product installer.You are required to thoroughly read all <br /> Standards installation instructions and product safety information before begin- a a a a a a a <br /> NOTE: ning the installation of this product. <br /> PROVIDE WCO WHERE SHOWN ON PLAN,AND ON Pc H55E NSF NUITUM DATE: SCALE: <br /> SANITARY WASTE BRANCHES NOT SERVED WITH A c o <br /> FLOOR CLEANOUT: LOCATED ABOVE FIXTURE FLOOR Inquire with governing authorities for local installation requirements 05/23/2022 <br /> RIM WITHIN 4'-0"OF FLOOR. CONSULT LOCAL CODES Standard:Listed by IAPMO,ASSE 1010 approved,ANSI 'The wetted surface of this product contacted by consumable SHEET TITLE: <br /> FOR OTHER WCO REQUIREMENTS. A112.26.1 M approved, PDI WH2O1 approved and certified. water contains less than 0.25%of lead by weight. <br /> PLUMBING <br /> SCALE <br /> WALL CLEANOUT DETAIL N.T.S 6 SCHEDULES & <br /> VAWAI I * DETAILS <br /> Watts product specifications in U.S.customary units and metric are approximate and are provided for reference only.For precise or mall rill , �WA ® USA: : (978)689-6066•F:(9 78) )332- 0 •Watts.com <br /> please contact Watts Technical Service.Watts reserves the right to change or modify product design,construction,specifications,or materials with- Canada: T:(905)332-4090•F:(905)332-7068•Watts.ca SHEET NO.: <br /> out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold. Latin America: T:(52)81-1001-8600•Watts.com <br /> ES-LF15M2 1329 ©2013 Watts <br /> P001 <br /> PLOT DATE: 5/23/2022 7:10:38 PM <br />