ELECTRICAL SPECIFICATIONS (AS APPLICABLE) ELECTRICAL SYMBOLS LIST <br /> V <br /> FKWALL FLR. DESCRIPTION <br /> DIVISION 16-ELECTRICAL . E <br /> SECTION 16000 ® ® DUPLEX RECEPTACLE AT+15"FOR WALL MOUNTED U.O.N. = O <br /> BASIC ELECTRICAL REQUIREMENTS ® DOUBLE DUPLEX RECEPTACLE AT+ 15"FOR WALL MOUNTED U.O.N. O Q <br /> K. DEMOLITION c. IF HVAC CONTROL WIRING IS REQUIRED TO BE RUN IN CONDUIT, IT SHALL BE A MINIMUM OF 3/4", UNLESS *1 V <br /> A. NOTE NOTED OTHERWISE ON DRAWINGS. R QJ <br /> 1. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF EXISTING WORK AND is <br /> e ® GROUND FAULT INTERRUPTING DUPLEX RECEPTACLE _ r_ V <br /> 1. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS THE DEMOLITION PROVIDED BY THE GENERAL CONTRACTOR. COORDINATE WITH THE GENERAL CONTRACTOR ANY d. ALL IN/UNDER FLOOR CONDUIT SHALL BE OF MINIMUM 3/4"SIZE. L <br /> AND ALL OTHER SPECIFICATION SECTIONS,APPLY TO THIS AND THE OTHER SECTIONS OF DIVISION 16. EXISTING EQUIPMENT REQUIRED TO BE LEFT INTACT. d •i a <br /> DUPLEX RECEPTACLE WITH USB 2.0 PORT <br /> 2. THE CONTRACTOR FOR THIS DIVISION OF WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW 2. THIS CONTRACTOR SHALL INCLUDE, AND WILL BE HELD RESPONSIBLE FOR, THE REMOVAL OF ALL EXISTING 4. SUPPORT ALL CONDUIT, INCLUDING SEISMIC AND SWAY BRACING, IN ACCORDANCE WITH THE NEC AND LOCAL e = O f>3 <br /> DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE ELECTRICAL EQUIPMENT, CONDUITS, ETC. NOT TO BE REUSED ON THIS PROJECT, UNLESS SPECIFICALLY NOTED CODES. O ,C <br /> WORK OF HIS SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTORS RESPONSIBILITY TO ® I® ® SPECIAL RECEPTACLE.SEE EQUIPMENT PLAN/INSTALLATION MANUAL FOR SPECS AND DETAILS. .� <br /> OTHERWISE. CONTRACTOR MUST VERIFY WITH THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT PRIOR TO <br /> PROVIDE HIS SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. REMOVAL. ALL EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF NOT APPLICABLE TO THE NEW WORK MUST BE 5. GENERALLY, ALL CONDUIT SHALL BE CONCEALED EXCEPT FOR UNFINISHED AREAS, SUCH AS EQUIPMENT ROOMS. _ r_ � <br /> REMOVED AND ROOF/WALL/FLOOR PATCHED/REPAIRED TO MATCH EXISTING STRUCTURE. EXISTING ABANDONED EXPOSED CONDUIT SHALL BE ALLOWED ONLY AS NOTED ON PLAN AND AS APPROVED BY PROJECT MANAGER. O J® JUNCTION BOXlD <br /> 3. THIS ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR SCHEDULING THE COMPLETION AND INSPECTION OF THIS CONDUIT OR EQUIPMENT IN THE FLOOR, EMBEDDED IN CONCRETE OR OTHERWISE INACCESSIBLE ARE TO BE CUT PAINTING OF CONDUITS, NOTED ON DRAWINGS OR SPECIFICATIONS WILL BE BY GENERAL CONTRACTOR. ' 3 M <br /> WORK TO COMPLY WITH TENANT/ARCHITECT'S SCHEDULE AND THE PROJECT COMPLETION DATE. OFF AND SEALED BELOW OR WITHIN FLOOR OR WALL LEVEL WHEN THEY ARE NOT TO BE REUSED IN THIS PROJECT. COMBINATION TELEPHONE, DATA AND CABLE OUTLET AT+18"U.O.N. O Ln v. <br /> IF REQUIRED BY LANDLORD OR CODES, ABANDONED CONDUIT MUST BE REMOVED TO POINT OF ORIGIN. CONFIRM 6. FLEXIBLE METAL CONDUIT OR MC TYPE CABLE: ® ® PROVIDE 1/2"C.O.STUBBED TO ACCESSIBLE CEILING SPACE a � <br /> 4. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTAL OF BID TO DETERMINE CONDITIONS AFFECTING THE THE EXTENT OF DEMOLITION PRIOR TO BID AND INCLUDE IN BID PROPOSAL. O 3 lD <br /> WORK. ANY ITEMS WHICH ARE NOT COVERED IN THE BID DOCUMENTS OR ANY PROPOSED SUBSTITUTIONS SHALL a. FLEXIBLE CONDUIT OR MC TYPE CABLE SHALL BE USED FOR THE FOLLOWING APPLICATIONS ONLY: TELEPHONE OUTLET;CAT5E CABLE. RJ11 TERMINATION MOUNTED AT+18" R V M <br /> BE LISTED SEPARATELY AND QUALIFIED IN THE CONTRACTORS BID. SUBMITTAL OF BID SHALL SERVE AS EVIDENCE ® ~ ® PROVIDE 1/2"C.O. STUBBED TO ACCESSIBLE CEILING SPACE V d <br /> OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT L. SLEEVES 1. FINAL CONNECTIONS TO MOTORS. �IN pp <br /> OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OF ® ® DATA OUTLET; CAT5E CABLE, RJ45 TERMINATION MOUNTED AT+18"U.O.N. V •� Y <br /> RESPONSIBILITY IN PERFORMANCE OF HIS WORK. 1. THIS CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACH 2. FINAL CONNECTIONS INTO AND OUT OF THE TRANSFORMER. PROVIDE 1/2"C.O.STUBBED TO ACCESSIBLE CEILING SPACE i M <br /> SLEEVE SHALL EXTEND THROUGH IT'S RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE CUT FLUSH WITH QJ m <br /> EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHICH SHALL EXTEND 2" ABOVE THE FLOOR. 3. FINAL CONNECTIONS TO VIBRATING EQUIPMENT. CABLE OUTLET; RG-6 COAXIAL CABLE. MOUNTED AT+18" U.O.N. QJ QJ <br /> 5. REFER TO RESPONSIBILITY SCHEDULE FOR INFORMATION IN REGARD TO RESPONSIBILITY OF WORK OR ITEMS ® ® S O <br /> WHICH MAY AFFECT THE BID. CONTRACTOR MUST COORDINATE THROUGH THE LANDLORD ANY CORE DRILLING OR CUTTING OF OPENINGS IN PROVIDE 1/2"C.O.STUBBED TO ACCESSIBLE CEILING SPACE N a <br /> 4. INTER-CONNECTIONS BETWEEN ALL LIGHT FIXTURES AND HOMERUNS TO PANELS WHERE CODE ALLOWS. • <br /> MASONRY FLOORS OR WALLS. LIGHTING FIXTURE WITH 90 MIN. EMER. BATTERY PACK OR ON INVERTER � Ln O <br /> 2. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND/OR FLOORS SHALL BE FIRE SEALED WITH CALCIUM 5. FINAL CONNECTIONS WHERE RIGID CONDUIT IN NOT PRACTICAL. O SEE LIGHT FIXTURE SCHEDULE FOR DETAILS AND SPECS W rq d <br /> B. GENERAL REQUIREMENTS SILICATE,SILICONE"RTV"FOAM,"31M"FIRE RATED SEALANTS OR EQUAL, SO AS TO RETAIN THEIR FIRE RATING. 6. IN WALLS(FOR LIGHT SWITCHES AND 120 VOLT POWER RECEPTACLES AND HVAC CONTROL EQUIPMENT). <br /> CONDUIT STUB OUT,3/4"MINIMUM-SEE PLANS FOR NOTES <br /> 1. THIS CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION, 3. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS, AND PARTITIONS SHALL BE STANDARD WEIGHT STEEL PIPE <br /> INCIDENTALS AND DETAILS NECESSARY TO PROVIDE A COMPLETE ELECTRICAL SYSTEM AS SHOWN ON THE FINISHED WITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED CEILINGS, OR b. FLEXIBLE METAL CONDUIT OR MC TYPE CABLE MUST BE THE SAME SIZE AS THE IMC OR EMT CONDUIT TO CONDUIT CONCEALED ABOVE CEILING OR IN WALLS <br /> DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS. ALL WORK NOT FOR CONCEALED VERTICAL PIPING, SLEEVES SHALL BE NO.22 U.S.G. GALVANIZED STEEL MINIMUM. WHICH IT IS CONNECTED. BOTH THE FLEXIBLE METAL CONDUIT AND IT'S FITTINGS ARE TO BE LISTED FOR Q� F ss/o q` <br /> SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR ARCHITECTS SHALL BE PROVIDED BY THIS CONTRACTOR. GROUNDING. A GREEN GROUNDING CONDUCTOR SHALL BE INSTALLED. ALL CONNECTORS ARE TO BE OF A 0,,.. . N <br /> CLOSELY COORDINATE THE ENTIRE INSTALLATION WITH THE LANDLORD AND ARCHITECTS,AS REQUIRED. M. HANGERS NEMA APPROVED TYPE. A-1 HOMERUN TO PANEL"A", CIRCUITS#1 =0FE JUN lFF.Fyc <br /> :y <br /> 2. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR 1. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, BANDS, C-CLAMPS WITH RETAINING c. THE USE OF ROMEX, BX, ETC. IS PERMITTED ONLY IN RESIDENTIAL CONSTRUCTION NOT HIGHER THAN THREE c>: <br /> GROUND CONNECTOR <br /> CALLED FOR IN ONE SHALL BE FURNISHED AND INSTALLED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. STORIES. �. 2 4 .z <br /> CLIPS, CHANNELS, HANGER RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK. P 2 <br /> ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, <br /> d. CONNECTION TO ANY OUTDOOR EQUIPMENT MUST BE WEATHERPROOF. ELECTRICAL PANELREFER TO PANEL SCHEDULE FOR DETAILS. <br /> BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK, AND WHICH IS USUALLY INCLUDED IN WORK OF 2. HANGERS SHALL BE FASTENED TO BUILDING STEEL, CONCRETE, OR MASONRY, BUT NOT TO PIPING. HANGING . <br /> SIMILAR CHARACTER,SHALL BE FURNISHED AND INSTALLED AS PART OF THE CONTRACT. FROM METAL DECK IS NOT PERMITTED. HANGERS MUST BE ATTACHED TO UPPER CHORD OF BAR JOIST. WHERE <br /> INTERFERENCES OCCUR, AND IN ORDER TO SUPPORT DUCTWORK OR PIPING, THE CONTRACTOR MUST INSTALL 7. PROVIDE PULL-WIRE IN ALL EMPTY CONDUITS EXCEPT AS NOTED OTHERWISE ON DRAWINGS. MAIN SWITCHBOARD OR POWER DISTRIBUTION BOARD.VERIFY DIMENSION WITH VENDER/MANUFACTURER. <br /> 3. WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES OR THE LANDLORD'S TENANT TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED WHERE THEY DO NOT INTERFERE WITH <br /> CRITERIA, THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING THE SYSTEM WITH THE MORE ACCESS TO FIRE DAMPERS, VALVES, AND OTHER EQUIPMENT. HANGER TYPES AND INSTALLATION METHODS ARE <br /> STRINGENT REQUIREMENTS AS DESIGNED AND DESCRIBED ON THESE DRAWINGS, UNLESS SPECIFICALLY NOTED ALSO SUBJECT TO LANDLORD CRITERIA. 8. HOME RUNS AND MAIN CONDUIT RUNS ARE TO BE HELD TIGHT TO STRUCTURE ABOVE OR AS REQUIRED TO ALLOW O DENOTES EQUIPMENT#1, SEE EQUIPMENT SCHEDULE FOR THE DETAILS AND EXACT SPECIFICATIONS. <br /> OTHERWISE. PROPER SERVICE ACCESS AND OTHER TRADES WORK. CONDUIT MUST BE TRAPEZED TO ALLOW 3 FEET MINIMUM <br /> 3. HANGERS AND PIPING OF DISSIMILAR METALS SHALL BE DIELECTRICALLY SEPARATED. CLEARANCE ABOVE CEILING. (D INDICATES PLAN NOTE NUMBER"1", SEE PLAN <br /> 4. ALL WORK IN THIS SECTION SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, N. FINAL ELECTRICAL INSPECTIONS <br /> MAINTAINING, AND REPAIRING. THIS CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUFFICIENT SERVICE ACCESS 9. ALL CONDUITS MUST BE SIZED PER NEC AND LOCAL CODES. <br /> TO ALL EQUIPMENT. 1. ASIDE FROM NORMAL INTERIM INSPECTIONS OF WORK IN PLACE,TENANT/ARCHITECTS MAY HAVE AN INDEPENDENT 10. ALL SENSORMATIC WIRING MUST BE PLACED IN CONDUIT(PVC PIPE NOT PERMITTED). DENOTES MECHANICAL EQUIPMENT#1 SEE MECHANICAL DRAWINGS FOR THE DETAILS AND SPECIFICATIONS. <br /> ELECTRICAL CONTRACTOR INSPECT THE FINISHED ELECTRICAL INSTALLATION UPON COMPLETION FOR <br /> 5. ALL WORK SHALL BE PERFORMED IN A NEAT PROFESSIONAL MANNER USING GOOD CONSTRUCTION PRACTICES. COMPLIANCE WITH THE PLANS, SPECIFICATIONS AND CODES.THE INSTALLING CONTRACTOR WILL BE RESPONSIBLE $ SINGLE POLE SWITCH AT 48"U.O.N. <br /> TO BRING ALL ITEMS REPORTED BY THE INDEPENDENT ELECTRICAL CONTRACTOR UP TO PLANS AND OUTLET BOXES <br /> 6. UNLESS SPECIFICALLY NOTED OTHERWISE, MATERIALS, PRODUCTS, AND EQUIPMENT, INCLUDING ALL SPECIFICATION REQUIREMENTS. <br /> COMPONENTS THEREOF, SHALL BE NEW, UNDERWRITERS LABORATORIES LISTED AND LABELED AND SIZED IN 1. ALL OUTLET BOXES SHALL BE GALVANIZED PRESSED STEEL OF THE STANDARD KNOCKOUT TYPE. NO ROUND 3 THREE-WAY SWITCH AT+48"U.O.N. <br /> CONFORMITY WITH REQUIREMENTS OF STATE AND LOCAL CODES,WHICHEVER IS MORE STRINGENT. END OF SECTION 16000 OUTLET BOXES SHALL BE PERMITTED UNLESS INDICATED AND FOR LIGHTING THAT REQUIRE SUCH <br /> CONFIGURATION. CONCEALED BOXES SHALL NOT BE LESS THAN 4"SQUARE AND 1 1/2"DEEP,WITH PLASTER RINGS. $m MANUAL MOTOR STARTER <br /> 7. THIS CONTRACTOR SHALL DO ALL CUTTING, CHASING AND CHANNELING REQUIRED FOR ANY WORK UNDER THIS <br /> DIVISION. CUTTING SHALL HAVE PRIOR APPROVAL BY THE ARCHITECTS AND THE LANDLORD. ALL PATCHING SHALL 2. ALL KNOCKOUT BOXES, UPON WHICH LIGHTING FIXTURES ARE TO BE INSTALLED, SHALL BE EQUIPPED WITH 3/8" <br /> BE BY G.C.AND SHALL MATCH THE SURROUNDING SURFACES. FIXTURE STUDS. 1 DIMMER SWITCH AT+48"U.O.N.SECTION 16050 <br /> 3. EXTERIOR BOXES SHALL BE CAST RUST-RESISTING METAL WITH GASKETED COVERS. n <br /> 8. THE ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL CONNECTIONS AS REQUIRED FOR A COMPLETE BASIC ELECTRICAL MATERIAL AND METHODS C. Lam3 THREE-WAY DIMMER SWITCH AT+48"U.O.N. <br /> AND OPERATING SYSTEM. 4. INSTALL BOXES RIGIDLY FROM BUILDING STRUCTURE AND SUPPORT INDEPENDENTLY OF THE CONDUIT SYSTEM. <br /> A. CONTRACTOR NOTES ALSO PROVIDE SUITABLE BOX EXTENSIONS TO EXTEND BOXES TO FINISHED FACES OF FLOORS, CEILINGS, WALLS OCCUPANCY AUTOMATIC WALL SWITCH SENSOR WITH SINGLE LEVEL <br /> C. TEMPORARY LIGHT AND POWER ETC.ALL OUTLET BOXES TO BE PROVIDED WITH CADDY"QUICK-MOUNT BOX SUPPORT"TO MINIMIZE THE DEFLECTION SWITCHING AT+48"U.O.N./MANUFACTURER TO BE DETERMINED <br /> 1. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION, THAT OCCURS WHEN PLUGGING/UNPLUGGING INTO THESE DEVICES. VACANCY AUTOMATIC WALL SWITCH SENSOR WITH SINGLE LEVEL <br /> 1. THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL TEMPORARY WIRING AND RELATED GROUND FAULT AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, vs <br /> INTERRUPTION PROTECTION FOR LIGHT AND POWER FOR ALL CONTRACTORS AND SHALL BE RESPONSIBLE FOR COMPLETION AND TESTING OF ALL THE WORK FOR THE ELECTRICAL SYSTEMS AS SHOWN ON THE DRAWINGS, <br /> 5. UNLESS OTHERWISE NOTED ON DRAWINGS OR OTHERWISE REQUIRED BY THE NATIONAL ELECTRICAL CODE, SWITCHING AT+48"U.O.N./MANUFACTURER TO BE DETERMINED <br /> THE REMOVAL OF ALL TEMPORARY WIRING. CALLED FOR IN THE SPECIFICATIONS,AND AS REQUIRED BY JOB CONDITIONS,TO INCLUDE, BUT NOT BE LIMITED TO HANDICAP CODES OR LOCAL CODES, OUTLET HEIGHTS SHALL BE AS FOLLOWS: OCCUPANCY SENSOR SINGLE POLE SWITCH WITH DIMMER CONTROL <br /> 2. THE GENERAL CONTRACTOR SETS UP ALL ELECTRICAL UTILITIES IN THE NAME OF THE TENANT. TENANT PAYS FOR EDTHE FOLLOWING: a. SWITCH HEIGHT 48"FROM FINISHED FLOOR TO TOP OF OUTLET. FEATURE AT+48"U.O.N./MANUFACTURER TO BE DETERMINED <br /> ALL UTILITIES THROUGHOUT CONSTRUCTION. a. A COMPLETE ELECTRICAL DISTRIBUTION SYSTEM INCLUDING THE INSTALLATION OF SAFETY AND DISCONNECT OS CEILING MOUNTED OCCUPANCY SENSOR <br /> b CONVENIENCE OUTLETS: MANUFACTURER TO BE DETERMINED <br /> SWITCHES, MOTOR STARTERS AND LIGHTING. IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO <br /> D. CODES INCLUDE IN HIS BID FOR PROVIDING SERVICE EQUIPMENT NECESSARY FOR TIE-IN TO LANDLORD'S MOUNTED ON WALL NO MORE THAN 48-INCHES, MEASURED FROM TO TOP OF THE RECEPTACLE OUTLET BOX CEILING MOUNTED VACANCY SENSOR <br /> DISTRIBUTION EQUIPMENT OR TO OBTAIN SERVICE FROM LOCAL UTILITY COMPANY. REFER TO ELECTRICAL OR RECEPTACLE HOUSING AND; NO LESS THAN 15-INCHES, MEASURED FROM THE BOTTOM OF THE O MANUFACTURER TO BE DETERMINED <br /> 1. ALL WORK SHALL CONFORM TO THE LANDLORD'S CRITERIA,THE STATE'S, COUNTY'S,CITY'S AND LOCAL CODES AND RESPONSIBILITY SCHEDULE AND ELECTRICAL POWER RISER DIAGRAM FOR ADDITIONAL INFORMATION. RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING, TO THE LEVEL OF THE FINISHED FLOOR OR WORKING <br /> ORDINANCES, SAFETY AND HEALTH CODES, NFPA CODES, ENERGY CODES AND ALL OTHER APPLICABLE CODES <br /> AND REQUIREMENTS. THIS CONTRACTOR SHALL INQUIRE INTO AND COMPLY WITH ALL APPLICABLE CODES, PLATFORM UNLESS OTHERWISE INDICATED OR HORIZONTALLY MOUNTED IN BASEBOARD BENEATH CABINETS, DL CEILING MOUNTED DAYLIGHT SENSOR <br /> ORDINANCES, AND REGULATIONS. THIS CONTRACTOR SHALL INCLUDE ANY CHANGES REQUIRED BY CODES IN THE b. CONTRACTOR MUST ALSO INCLUDE IN BID ALL NECESSARY MATERIALS REQUIRED TO COMPLETE THE SYSTEM AS SHOWN ON DRAWINGS,OR AS REQUIRED BY LOCAL CODES,SEE DRAWINGS. MANUFACTURER TO BE DETERMINED <br /> BID AND IF THESE CHANGES ARE NOT INCLUDED IN THE BID,THEY MUST BE QUALIFIED AS A SEPARATE LINE ITEM IN INCLUDING, BUT NOT LIMITED TO, FEEDERS, BRANCH CIRCUITS, JUNCTION BOXES, OUTLET BOXES, WIRING HARD WIRED,WITH BATTERY BACKUP,SMOKE DETECTOR/CARBON MONOXIDE DETECTOR/MULTI-PURPOSE <br /> THE BID.AFTER CONTRACT IS AWARDED, CHANGE ORDERS FOR INCREASED COSTS DUE TO CODE ISSUES WILL NOT DEVICES, COVER PLATES,CONDUITS, ETC. c. TELEPHONE OUTLETS SHALL BE LOCATED AS NOTED ON DRAWINGS. OS O sic CARBON MONIXIDE&SMOKE DETECTOR. <br /> BE ACCEPTED BY OWNER, UNLESS ALLOWANCES HAVE PREVIOUSLY BEEN AGREED UPON. I` <br /> c. METERING <br /> AND CURRENT TRANSFORMERS AS REQUIRED BY DRAWINGS, UTILITY COMPANY, AND/OR JUNCTION AND PULL BOXES ❑J NON-FUSED/FUSED SWITCH, SIZE AS SHOWN IN THE PLAN C) <br /> LAN <br /> E. LICENSES, PERMITS, INSPECTIONS&FEES 1. THE PLANS INDICATE ONLY SCHEMATIC ROUTINGS FOR CONDUIT RUNS. THIS CONTRACTOR SHALL FURNISH AND w <br /> 1. THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS, INSPECTIONS, AND FEES REQUIRED OR <br /> d. THE WIRING OF MECHANICAL EQUIPMENT AS OUTLINED ON THE BID SET DRAWINGS AND IN THE INSTALL ADDITIONAL BOXES WHERE REQUIRED BY FIELD CONDITIONS OR BY CODE. MOTOR OUTLET-IDENTIFICATION <br /> RELATED TO HIS WORK. SPECIFICATIONS. WORK SHALL INCLUDE WIRING OF ALL STARTERS, DISCONNECTS, AND POWER WIRING OF Q Q <br /> MECHANICAL EQUIPMENT EXCEPT AS SPECIFICALLY NOTED OTHERWISE. ALL LOW VOLTAGE (24 VOLT) EMS 2. BOXES AND COVERS SHALL BE GALVANIZED STEEL OF CODE GAUGE SIZE. ® EXHAUST AIR GRILLE-REFER TO MECHANICAL PLANO z <br /> 2. FURNISH TO ARCHITECTS ALL CERTIFICATES OF INSPECTION AND FINAL INSPECTION APPROVAL AT COMPLETION OF TEMPERATURE CONTROL WIRING SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR UNLESS <br /> NOTED SPECIFICALLY ON DRAWING. 3. INSTALL BOXES RIGIDLY SUPPORTED FROM THE BUILDING STRUCTURE AND SUPPORTED INDEPENDENT OF THE TIME CLOCK WITH MANUAL BY-PASS SWITCH <br /> PROJECT. CONDUIT SYSTEM. 7c 1 <br /> SEE LIGHTING CONTROL DIAGRAM FOR DETAILS O <br /> F. TRADE NAMES, MANUFACTURERS AND SHOP DRAWINGS e. INSTALLATION OF LIGHT FIXTURES AND LAMPS AS SHOWN ON THE DRAWINGS INCLUDING ALL DEVICES, D. 4. ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION 1 1 1 uj LL <br /> EQUIPMENT, ETC. REQUIRED FOR MOUNTING. BOXES ABOVE DRYWALL CEILINGS SHOULD BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR S❑ GAS SOLENOID SEE PLUMBING PLAN FOR EXACT LOCATION. ui > J <br /> 1. WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS, THE DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. I Y Q Q <br /> EXACT EQUIPMENT SHALL BE USED AS A MINIMUM FOR THE BASE BID. MANUFACTURERS CONSIDERED AS AN EQUAL f. A COMPLETE CONDUIT SYSTEM FOR TELEPHONE/DATA INCLUDING BRANCH CONDUITS, OUTLET BOXES, PULL CL CURRENT LIMITER FOR TRACK LIGHTING FIXTURE. 1A RATED U.O.N. 1••� U <br /> OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL BE SUBJECT TO APPROVAL IN WRITING BY WIRES, GROUND CONDUCTORS, COVER PLATES, ETC. OR AS SPECIFICALLY NOTED OTHERWISE ON THE 5. JUNCTION AND PULL BOXES MUST BE LABELED WITH CIRCUIT NUMBER IDENTIFICATION AND SYSTEM TYPE ON ♦^ U_ <br /> ARCHITECTS/ENGINEERS THROUGH SHOP DRAWING SUBMITTAL PROCESS FOR ACCEPTANCE PRIOR TO DRAWINGS. COVER. v, z <br /> INSTALLATION.THE USE OF ANY UNATHORIZED EQUIPMENT SHALL BE REPLACED AT THE CONTRACTOR'S EXPENSE. (N)/(E)/(R) ABBREVIATION FOR NEW/EXISTING/REPLACED. <br /> 2. GENERAL CONTRACTOR SHALL SUBMIT ONLY SUBSTITUTION REQUESTS TO ARCHITECTS/ENGINEERS FOR 9. A COMPLETE EMERGENCY AND EXIT LIGHTING SYSTEM AS SHOWN ON THE DRAWINGS. WIRING >_ r , O <br /> SYMBOL NOTES: <br /> APPROVAL. SUBMISSIONS SHALL BE MADE EARLY ENOUGH IN PROJECT TO ALLOW FOUR (4) WORKING DAYS FOR z Y <br /> ARCHITECTS/ENGINEERS REVIEW WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS. h. TEMPORARY SERVICE AS INDICATED IN THE SPECIFICATIONS, INCLUDING ITS REMOVAL. 1. CONDUCTORS FOR FEEDERS AND BRANCH CIRCUITS SHALL BE COPPER AND THE AWG SIZE AND TYPE AS SHOWN SYMBOL LIST SHOW IN FOR GENERAL REFERENCE ONLY.A PRESENCE OF A SYMBOL DOES NOT IMPLY ITS USE ON THIS PROJECT. U <br /> SUBMITTALS SHALL BEAR THE STAMP AND/OR THE SIGNATURE OF THE GENERAL CONTRACTOR AND THE ON DRAWINGS. MINIMUM WIRE SIZE #12. THE CONDUCTORS SHALL BE 600 VOLT INSULATION, TYPE THW, THWN OR REFER TO DRAWING FOR SPECIFIC SYMBOLS USED. z I` <br /> SUB-CONTRACTOR SHOWING THAT HE HAS REVIEWED AND CONFIRMED THAT THE SUBMITTALS ARE IN THHN. O <br /> CONFORMANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS HAVE L FINAL CONNECTIONS TO ALL SIGNS,CORNICE LIGHTING,CASE LIGHTING, ETC.AS SHOWN ON DRAWINGS. LIJ <br /> SHEET INDEX L <br /> BEEN TAKEN. 2. MINIMUM WIRE SIZE - 20 AMP BRANCH CIRCUIT SHALL BE AWG LISTED SIZE PER DISTANCE SHOWN BELOW. <br /> DISTANCE SHALL BE MEASURED FROM THE PANELBOARD CIRCUIT BREAKER TO THE FURTHEST OUTLET. <br /> G. GUARANTEE j. IF INDICATED ON DRAWINGS, INSTALLATION AND WIRING OF SPEAKERS, AMPLIFIERS, CONDUIT AND FINAL <br /> a. #12 LESS THAN 100 FEET <br /> 1. THE EQUIPMENT MANUFACTURER SHALL PROVIDE A 12 MONTH GUARANTEE TO TENANT FROM THE DATE OF CONNECTIONS FOR SOUND SYSTEM AS SHOWN. E. E000 ELECTRICAL SPECIFICATION <br /> ACCEPTANCE. THIS CONTRACTOR SHALL WARRANTY THE INSTALLATION OF THIS EQUIPMENT AND WILL BE k. SMOKE/FIRE ALARM WIRING, DEVICES AND CONDUIT, AS SHOWN OR DESCRIBED ON DRAWINGS OR AS b. #10 BETWEEN 100-150 FEET E001 SINGLE LINE DIAGRAM/SCHEDULES <br /> RESPONSIBLE FOR ANY DAMAGE AND/OR MALFUNCTION CAUSED BY THE INSTALLATION.THIS CONTRACTOR SHALL NECESSARY TO MEET LANDLORD,STATE, LOCAL, INSURANCE AND FIRE DEPARTMENT REQUIREMENTS. E100 ELECTRICAL PLAN <br /> NOT BEAR ADDITIONAL WARRANTIES BEYOND A COMPLETE WORKING SYSTEM. c. #8 BETWEEN 150-250 FEET <br /> I. INSTALLATION OF CONDUITS STUBBED TO ABOVE CEILING FOR HVAC. ALSO, ANY ADDITIONAL CONDUIT FOR TE00 TITLE 24 <br /> H. RECORD DRAWINGS HVAC CONTROL EQUIPMENT WHERE PLENUM RATED CABLES ARE NOT PERMITTED. d. #6 OVER 250 FEET <br /> 1. THIS CONTRACTOR SHALL MAINTAIN ONE SET OF DRAWINGS ON THE JOB SITE UPDATED WEEKLY TO RECORD ALL m. BALANCING LOADS. 3. ON ALL 20 AMP BRANCH CIRCUITS, CONDUCTORS LARGER THAN #10 AWG SHALL BE REDUCED TO#10 AWG WITHIN <br /> DEVIATIONS FROM CONTRACT DRAWINGS,SUCH AS: n. AS-BUILTS, PANEL DESCRIPTION AND CIRCUIT BREAKER SPECIFIC LABELING. 10 FEET OF PANEL BOARD AND DEVICE IN JUNCTION BOXES ON RATED TERMINAL STRIPS. Z <br /> a. LOCATION OF CONCEALED CONDUIT AND EQUIPMENT. 4. CONDUCTORS MAY BE STRANDED FOR SIZES#10 AWG AND LARGER. CONDUCTORS SIZE#12 SHALL BE SOLID (NOT 0 <br /> STRANDED). <br /> 2. THE FOLLOWING ITEMS OF ELECTRICAL CONSTRUCTION ARE NOT INCLUDED IN THIS CONTRACT: <br /> b. REVISIONS,ADDENDUMS,AND CHANGE ORDERS. Lu <br /> 5. ALUMINUM CONDUCTORS ARE NOT PERMITTED, EXCEPT AT SERVICE ENTRANCE,WHERE REQUIRED BY LANDLORD. Of <br /> c. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVED EQUIPMENT SUBSTITUTIONS, a. TELEPHONE INSTRUMENTS AND WIRING UNLESS NOTED OTHERWISE. CONDUCTOR CONNECTION MUST BE PER MANUFACTURER'S REQUIREMENTS. CONTRACTOR MUST OBTAIN WRITTEN <br /> AND CONTRACTOR'S COORDINATION WITH OTHER TRADES. b. DATA CABLE WIRING UNLESS NOTED OTHERWISE. PERMISSION FROM GENERAL CONTRACTOR AND PROJECT MANAGER WHEN USED. <br /> 6. ALL WIRING SHALL BE IN CONDUIT, UNLESS SPECIFICALLY NOTED OTHERWISE (IE. LOW VOLTAGE PLENUM RATED <br /> 2. AT COMPLETION OF THE PROJECT AND BEFORE FINAL APPROVAL, THIS CONTRACTOR SHALL MAKE ANY FINAL 3. BEFORE STARTING WORK, THIS CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, FIRE WIRE). a a a <4<4:d <br /> CORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON. FAILURE TO PROTECTION, MECHANICAL AND PLUMBING PLANS, SHOP DRAWINGS AND SPECIFICATIONS TO SEQUENCE, <br /> KEEP THESE RECORDS WILL ALLOW TENANT/ARCHITECTS TO DIRECT THE GENERAL CONTRACTOR TO PROVIDE COORDINATE,AND INTEGRATE THE VARIOUS ELEMENTS OF THE ELECTRICAL SYSTEM, MATERIALS AND EQUIPMENT <br /> THESE RECORDS AT HIS EXPENSE PRIOR TO FINAL PAYMENT. WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. 7. THE USE OF SHARED NEUTRALS IS REQUIRED FOR LIGHTING CIRCUITS AND SHALL BE INSTALLED IN ACCORDANCE DATE: SCALE: <br /> WITH THE NATIONAL ELECTRICAL CODE AND LOCAL CODES. ALL OTHER EQUIPMENT REQUIRING A NEUTRAL 5/09/2022 N.T.S. <br /> B. CONDUIT CONDUCTOR SHALL HAVE A DEDICATED FULL SIZE NEUTRAL. <br /> I. DISCREPANCIES IN DOCUMENTS SCOPE OF WORK SHEET TITLE: <br /> 1. THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL CONDUITS SERVING ALL EQUIPMENT, INCLUDING BUT NOT <br /> LIMITED TO, LIGHTING, RECEPTACLES, HEATING, AIR CONDITIONING, PLUMBING EQUIPMENT, TELEPHONE, DATA, 8. THE USE OF ROMEX, BX, ETC. IS PERMITTED ONLY IN RESIDENTIAL CONSTRUCTION NOT HIGHER THAN THREE <br /> 1. DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION SPEAKERS, SECURITY, PAGER,TRAFFIC COUNTING SYSTEM AND ELECTRICAL EQUIPMENT. STORIES. <br /> AND INTENT OF THE ELECTRICAL SYSTEMS. WHERE DRAWINGS, EXISTING SITE CONDITIONS, SPECIFICATIONS OR ELECTRICAL <br /> OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE THE GENERAL CONTRACTOR IN WRITING, PRIOR TO 9. WIRE CONNECTORS SHALL BE EQUAL TO "SCOTCH LOCK" FOR #8 AWG WIRE AND SMALLER AND EQUAL TO T & B • EXISTING COMMERCIAL TENANT IMPROVEMENT. <br /> SUBMITTAL OF BID. THE GENERAL CONTRACTOR IS RESPONSIBLE TO ADVISE PROJECT MANAGER, IN WRITING, OF 2. ALL CONDUITS SHALL BE GALVANIZED IMC OR EMT UNLESS OTHERWISE SPECIFIED IN SPECIFICATIONS OR ON "LOCKTIGHT"FOR#6 AWG AND LARGER. SPECIFICATION <br /> R <br /> VARIATIONS F CONTRACT DOCUMENTS PRIOR RE SUBMISSION OF BID. OTHERWISE, TENANT/ARCHITECT'S DRAWINGS.ALL CONDUIT IS TO BE UL LABELED. EMT CONNECTORS SHALL BE STEEL COMPRESSION OR SET SCREW PROVIDE NEW LIGHTING FIXTURES/CONNECTIONS TO THE RENOVATED AREAS. <br /> INTERPRETATION OF CONTRACT DOCUMENTS OR CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL TYPE. CONDUIT UNDER SLAB ON GRADE SHALL BE RIGID STEEL, OR SCHEDULE 40 PVC WITH RIGID STEEL ELLS <br /> COMPENSATION PERMITTED. WHERE PERMITTED BY LANDLORD OR CODE. 10. ALL WIRING TO BE COLOR-CODED AS FOLLOWS: • EXISTING MAIN SERVICE AND SERVICE/DISTRIBUTION EQUIPMENT TO BE UTILIZED. <br /> 3. MINIMUM SIZE OF CONDUIT SHALL BE: 120/208 VOLT SYSTEM 277/480 VOLT SYSTEM <br /> J. PHASING REQUIREMENTS NEUTRAL-WHITE NEUTRAL-GRAY <br /> a. MAIN FEEDER CONDUIT 2"OR LARGER FOR ALL APPLICATIONS. PHASE A OR L1 -BLACK PHASE A OR L1 -YELLOW EOOO <br /> 1. THIS CONTRACTOR IS TO INCLUDE IN HIS BID ALL NECESSARY SERVICE REQUIRED TO KEEP THE OPERATING PHASE PHASE B OR L2-RED PHASE B OR L2-ORANGE <br /> OF THE STORE'S ELECTRICAL SERVICE IN OPERATION. CONTRACTOR MUST SCHEDULE IN WRITING WITH b. 1/2" FOR INDIVIDUAL LIGHTING FIXTURE CONNECTIONS OR TO INDIVIDUAL LIGHT SWITCHES(IF ACCEPTABLE BY PHASE C OR L3-BLUE PHASE C OR L3-BROWN <br /> TENANT/ARCHITECTS AND THE LANDLORD ONE WEEK PRIOR TO ANY SHUT DOWN OF THE ELECTRICAL SYSTEM. THE LANDLORD AND LOCAL CODE OFFICIALS)AND 3/4"FOR ALL OTHER LOCATIONS. GROUND-GREEN GROUND-GREEN WITH YELLOW TRACER <br /> PLOT DATE: 5/10/2022 3:17:39 PM <br />