My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1789
>
2300 - Underground Storage Tank Program
>
PR0506538
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/11/2023 11:02:49 AM
Creation date
2/24/2023 8:59:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0506538
PE
2361
FACILITY_ID
FA0007486
FACILITY_NAME
COUNTRY MARKETPLACE
STREET_NUMBER
1789
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16337023
CURRENT_STATUS
01
SITE_LOCATION
1789 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANINJOAQUIN <br />_-ccUNrY— <br />Fac it l amo■ <br />COUNTRY MARKETPLACE <br />Itor <br />Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Facility ddro s: <br />1 789 W CHARTER IA, STOCKTON <br />SUMMARY QF VIOLATIONS <br />(CLASS I, CLASS 1I, or MINOR - Notice to Comply) <br />Remarks <br />DOW <br />March 0, 2023 <br />306 HSC 25291tej Failure to remove, analyze, and properly dispose of water in secondary containment (pre -Jul 2003) <br />OBSERVATION, Liquid was observed in the 87 STP sUmp. 87 and 91 fill containers. <br />REGULATION GUIDANCE: If water could enter into the secondary containment by precipitation or infiltration, it <br />must be removed and disposed of properly <br />CORRECTIVE ACTIN The service technician removed approximately one gallon of liquid from the 87 STP sume, <br />$7 and 91 spill containers. Ensure that all sumps and annular spices are maintained free of liquid. <br />This was corrected ars site. 4 <br />- I N) a� - le C/ 6; 6 <br />Vo 144, <br />1475 <br />This is a repeat violation, Class II. <br />:319 1 CCR 2635, 2637.2h 2665, 2712 Failure to comply with overfill prevention equipment requirements_ <br />BSE RVAT10N - The two tanks 87 and 9 1 du not have a n approve overftll pr ven ion system, <br />REGULATION GUI# A E: All underground storage tanks shall be equipped with an overfill prevention system that <br />does not allow for manual override and meets one of the following r quir r hent ` <br />I . Alert the transfer operator when the taflk i s 90 percent f u I I by restricting the flow into the tank or triggering a n <br />audible and visual alarm,. or <br />. Restrict delivery of flow to the tank at least 30 minules before the tank dills, provided th a restriction o ur <br />when the tank is filled to no more than 95 percent of capacity; and activate an audible alarm at least five minutes <br />before the tank overfills; or <br />. Provide positive shut-off of flow to the teak when the tank is filled to no more than 95 percent of capacity, or, <br />. Provide positive shut-off of flaw to the tank o that none of the fittings located on the top of the tank are <br />exposed to product due to overfilling <br />CORRECTIVE ACTION: Immediately contact a property licensed, trained, and certified contractor to install an <br />approved overfill prevention system- Replacement of a mechanical Bopp r valve requires a permit and inspection <br />by the EHD.. If an external audio/visual alarm Js replaced, provide a copy of the service receipt to the EH D if an <br />approved overfill prevent -ion system can't be installed immediately, diately, there is a possibilrt that the 87 and 91 UST <br />system may be red tagged to prevent fuel inputs, % 4 A <br />Me <br />This � r repeat violation, is II. <br />Overal I Inspection C <br />An inspection checklist was provided to the facility operator an the day of €nspectian. A complete report was <br />finished on 03/08/2023 and replaces the initial checklist. <br />Complete and submit a copy of the Return to Compliance Certification firm to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, within 30 days at receiving the complete inspection report_ <br />E+02 -W1 Rev IWV2021 Page 5 4f 8 <br />1 X68 E Hazelton Avenue I Stockton, California 95205 T 209 488-3420 1 <br />F074 8 PR05(*538 SCO01 WM703 <br />Underground Storage Teak Program OR <br />F 209 464-0138 1 wmv.sjgov orglEHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.