Environmental Health Department
<br />Facility Name and Address: BASILS PLACE, 2324 GRAND CANAL BLVD, STOCKTON 95207
<br />Food Program Official Inspection Report
<br /> #38 Approved / Sufficient Ventilation and Lighting
<br />OBSERVATIONS: A fryer is being used in the kitchen and steaks are cooked on the stove top without a class I hood. Install
<br />a class I hood approved by the EHD or adjust menu offerings to exclude items that produce grease.
<br />CALCODE DESCRIPTION: Exhaust hoods shall be provided to remove toxic gases, heat, grease, vapors and smoke and be approved by
<br />the local building department. Canopy-type hoods shall extend 6" beyond all cooking equipment. All areas shall have sufficient ventilation
<br />to facilitate proper food storage. Toilet rooms shall be vented to the outside air by a screened openable window, an air shaft, or a
<br />light-switch activated exhaust fan, consistent with local building codes. (114149, 114149.1) Adequate lighting shall be provided in all areas
<br />to facilitate cleaning and inspection. Light fixtures in areas where open food is stored, served, prepared, and where utensils are washed
<br />shall be of shatterproof construction or protected with light shields. (114149.2, 114149.3, 114252, 114252.1)
<br /> #40 Proper Use and Storage of Wiping Cloths
<br />OBSERVATIONS: The mop sink was full of cleaning cloths. Maintain mop sink clear of items for the disposal of waste
<br />water. Correct today.
<br />CALCODE DESCRIPTION: Wiping cloths used to wipe service counters, scales or other surfaces that may come into contact with food
<br />shall be used only once unless kept in clean water with sanitizer. (114135, 114185.1 114185.3 (d-e))
<br /> #41 Plumbing Maintained; Approved Back Flow Device
<br />OBSERVATIONS: The 3 - compartment sink at the bar is lacking an air gap. Provide a gap distance of one inch minimum
<br />between the end of the waste pipes and the top of the floor sink. Correct within one week.
<br />CALCODE DESCRIPTION: The potable water supply shall be protected with a backflow or back siphonage protection device, as required
<br />by applicable plumbing codes. (114192) All plumbing and plumbing fixtures shall be installed in compliance with local plumbing
<br />ordinances, shall be maintained so as to prevent any contamination, and shall be kept clean, fully operative, and in good repair. Any hose
<br />used for conveying potable water shall be of approved materials, labeled, properly stored, and used for no other purpose. (114171,
<br />114189.1, 114190, 114193, 114193.1, 114199, 114201, 114269)
<br /> #45 Floors, Walls, Ceilings; Clean and Maintained
<br />OBSERVATIONS: Several ceiling tiles were missing in the storage room. Replace ceiling tiles within 30 days.
<br />Several floor tiles were missing in the kitchen. Replace missing floor tiles with so that floor is smooth, cleanable and
<br />non-absorbent within 30 days.
<br />CALCODE DESCRIPTION: The walls / ceilings shall have durable, smooth, nonabsorbent, light-colored, and washable surfaces. All floor
<br />surfaces, other than the customer service areas, shall be approved, smooth, durable and made of nonabsorbent material that is easily
<br />cleanable. Approved base coving shall be provided in all areas, except customer service areas and where food is stored in original
<br />unopened containers. Food facilities shall be fully enclosed. All food facilities shall be kept clean and in good repair. (114143 (d),
<br />114266, 114268, 114268.1, 114271, 114272)
<br />Page 3 of 4EHD 16-23 Rev. 09/16/2020 Food Program OIR
<br />FA0001738 PR0160391 SC001 03/10/2023