Laserfiche WebLink
SYSTEM SET-UP REPORT (Page 3) <br /> PLLD LINE DISABLE SETUP Q 3:DIESEL EVR/ISD SETUP <br /> IN-TANK ALARMS <br /> 0 1 :REGULAR T 3:HIGH WATER ALARM <br /> T 3:LOW PRODUCT ALARM EVR TYPE: BALANCE <br /> IN-TANK ALARMS <br /> T ] :HIGH WATER ALARM LIQUID SENSOR ALMS BALANCE NOZZLE TYPE <br /> T ]:LOW PRODUCT ALARM L 7:FUEL ALARM VST <br /> L 9:FUEL ALARM <br /> LIQUID SENSOR ALMS L10:FUEL ALARM VAPOR PROCESSOR TYPE SOFTWARE REVISION LEVEL <br /> L 2:FUEL ALARM L11 :FUEL ALARM VEEDER-ROOT POLISHER VERSION 334.01 <br /> L 9:FUEL ALARM L12:FUEL ALARM SOFTWARE# 346334-100-B <br /> L10:FUEL ALARM L 7:SENSOR OUT ALARM CREATED - 17.01.09.16.10 <br /> L11:FUEL ALARM L SENSOR OUT ALARM ANALYSIS TIMES <br /> L12:FUEL ALARM _11b:,.tNSOR OUT ALARM TIME: 10:00 AM S-MODULE# 330160-004-a <br /> L 2:SENSOR OUT. ALARM L11 :SENSOR OUT ALARM DELAY MINUTES: 1 SYSTEM FEATURES: <br /> L 9:SENSOR OUT ALARM L12:SENSOR OUT ALARM PERIODIC IN-THNK TESTS <br /> L10:SENSOR OUTIALARM ANNUAL IN-TANK TESTS <br /> L11:SENSOR OUT ALARM SMARTSENSOR ALARMS ACCEPT HIGH ORVR: ISD/APM <br /> L12:SENSOR OUT ALARM s10:HIGH LIQUID ALARM ENABLED <br /> AIARTSENSOR ALARMS SMARTSENSOR SETUP ISD HOSE TABLE <br /> s 5:HIGH LIQUID ALARM - - - - - - - - - - - - ID FP FL HL AA RR <br /> ------------------------ <br /> ISD SITE ALARMS s ] :DISP 1-2 AFM 01 00 01 02 01 00 <br /> ISD GROSS PRES FAIL CATEGORY AIR FLOW METER 02 01 02 02 01 00 <br /> ISD DEGRD PRES FAIL 03 02 03 02 02 00 <br /> ISD VAPOR LEAK FAIL s 2:DISP 3-4 AFM 04 03 04 02 02 00 <br /> ISD VP PRES FAIL CATEGORY AIR FLOW METER 05 04 05 02 03 00 <br /> ISD VP STATUS FAIL 06 05 06 02 03 00 <br /> s 3:DISP 5-6 AFM 07 06 07 02 04 00 <br /> ISD HOSE ALARMS CATEGORY AIR FLOW METER 08 07 08 02 04 00 <br /> ALL:GROSS COLLECT FAIL <br /> ALL:DEGRD COLLECT FAIL s 4:DISP 7-8 AFM <br /> ALL:FLOW COLLECT FAIL CATEGORY AIR FLOW METER ISD AIRFLOW METER MAP <br /> ID SERIAL NUM LABEL <br /> 0 2:PREMIUM s 5:REGULAR PRODUCT VHC ------- <br /> CATEGORY VAC SENSOR 1 74848 DISP 1-2 A <br /> IN-TANK ALARMS PUMP #: 2 74624 DISP 3-4 A <br /> T 2:HIGH WATER ALARM 0 1 :REGULAR 3 74946 DISP 5-6 A <br /> T 2:LOW PRODUCT ALARM VOLUME: 48.3 GALLONS 4 74820 DISP 7-8 A <br /> RELIEF VALVE: : NO <br /> LIQUID SENSOR ALMS <br /> L 5:FUEL ALARM s 6:VAPOR LINE VAC ISD FUEL GRADE HOSE MAP <br /> L 9:FUEL ALARM CATEGORY UAC SENSOR 1 2 3 4 <br /> L10:FUEL ALARM PUMP #: FP MHH MHH MHH MHH AA <br /> L11 :FUEL ALARM Q I:REGULAR --------------- <br /> L12:FUEL ALARM VOLUME: 62.1 GALLONS 00 001 901 101 2 U 1 <br /> L 5:SENS0146PUT HLHRM RELIEF VALVE: : NO 01 002 902 102 2 U 1 <br /> L 9:SENSOR OUT ALARM 02 003 903 103 2 U 2 <br /> L10:SENSOR OUT ALARM s 7:PREMIUM PRODUCT VAC 03 004 904 104 2 U 2 <br /> L11:SENSOR OUT ALARM CATEGORY VAC SENSOR 04 005 905 105 2 U 3 <br /> L12:SENSOR OUT ALARM PUMP #: 05 006 906 106 2 U 3 <br /> Q 2:PREMIUM 06 007 907 107 2 U 4 <br /> SMARTSENSOR ALARMS VOLUME: 41.4 GALLONS 07 008 908 108 2 U 4 <br /> s 7:HIGH LIQUID ALARM RELIEF VALVE: : NO <br /> ISD SITE ALARMS s 8:ATMP LABEL TABLE <br /> ISD GROSS PRES FAIL --------------------- <br /> CATEGORY ATM P SENSOR <br /> ISD DEGRD PRES FAIL 1: UNASSIGNED <br /> ISD VAPOR LEAK FAIL s 9:VENT LINES VAC 2: BLEND3 <br /> ISD VP PRES FAIL CATEGORY VAC SENSOR 3: REGULAR <br /> ISD VP STATUS FAIL PUMP #: 4: MID GRADE <br /> Q 2:PREMIUM 5: PREMIUM <br /> ISD HOSE ALARMS VOLUME: 40.3 GALLONS 6: GOLD <br /> ALL:GROSS COLLECT FAIL RELIEF VALVE: : NO 7: BRONZE,. <br /> ALL:DEGRD COLLECT FAIL 8: SILVER <br /> ALL:FLOW COLLECT FAIL s10:DIESEL PRODUCT VAC 9: BLEND2 <br /> CATEGORY VAC SENSOR 10: BLEND4 <br /> PUMP #: <br /> Q 3:DIESEL <br /> VOLUME: 36.8 GALLONS <br /> RELIEF VALVE: : NO <br /> s11:VAPOR PRESSURE <br /> CATEGORY VAPOR PRESSURE <br /> s12:VEEDER-ROOT POLISHER <br /> CATEGORY VAPOR VALVE <br /> ©2018 Walton Engineering,Inc. <br />