Laserfiche WebLink
Sterilization certified in line with M P <br />EN ISO 13485:20161 EN ISO 11135:2014 <br />Confirmation of Sterilization <br />Method: VAS 1 <br />Sterilization date: 202041-18 <br />Sterilization lot: 18599 <br />Customer. MT.DERM GmbH <br />Your requisition no.: 11112020 <br />GB18=20-EB3386,GB30=20-EB3406,GB10=20-EB3407,GB11=20 83414, <br />GB8=20-EB3415,G B4=20•ES3416 <br />Our delivery note: 253088 from 2020-11-20 <br />Item: 9900031 <br />Sterilisation Pal, MP01 1d NK <br />Pr.70 <br />Quantity: 6 Pal. <br />Nominal values Actual values <br />Incomina time: min. 12 h 127 h <br />Precondition!no <br />Dwell: min. 16 h 23375 h <br />Conditions: 35-45°C 50-800/6rel.humidity 35-45°C 50-80%rel.humidity <br />Sterllizatlon <br />Cycle: MP1 <br />Temperature: 401:3 °C 40 °C <br />Prevacuum: 120 t10 mbar abs 125 mbar abs <br />Humidity: 50-80%rel.humidily 70,5% rel.humidity <br />Dwell time: 3 h 3 h <br />EO mass: 1632 kg 26 kg <br />Airwashes: min. 3 3 <br />Aeration <br />Dwell: <br />1 5 Days <br />Condition: <br />min. 1 Days , <br />35.45 °C 35.45 °C <br />Remarks: The evaluation from the BI's is in process. <br />The physical parameters were in accordance to the specifications. <br />No growth was observed for the microbiological inprocess control with biobgical <br />indicators (Bacillus atrophaeus, 3M Attest). <br />The sterilization was conducted in line with the customer validation parameter. <br />TITMEM <br />Signature <br />QS: <br />