Laserfiche WebLink
ARCH ITECTURE <br /> DAL-1 <br /> 3 F3-] 60x24 <br /> 275 CF 275 CF 200 CFM 200 CFM 200 CFM <br /> CS-4 CS-4 CS-4 CS-4 CS-4 <br /> 12x12 12x12 2 10x10 10x10 10x10 <br /> 91� 6'0 ARCHITECT <br /> it" <br /> 12"0 T810 <br /> 4"0 WO� <br /> 9"� 12"� FSD IEF-5 8"� 8"� WS-1 NJ ASSOCIATES <br /> 275 CFM 22769 N BENDER ROAD <br /> 1 <br /> 12'� 9'� 12x6 ACAMPO CA 95220 <br /> CC7"� 209.727.2040 <br /> www.njaarchitecture.com <br /> IEF-3 TF4150 CF <br /> CS-4 16'0 <br /> 12x12 CLIENT <br /> JOE HADDAD <br /> FAU-15 250 CFM = WS 1CFMIYI P.O. BOX 691863 <br /> o a CE-1 9"� 12x6 STOCKTON CA 95629 <br /> 2000 CFM 10x10 <br /> DS-1 2000 CFM 2 0 C O O 209 481 8981 <br /> tt 24x22 DR-1 17 <br /> 24x22 0 0 7.0 ~ <br /> 150 CFM <br /> CS-4 PROJECT <br /> WIF 1J+ 10_x_10 ® 2000 CFM <br /> = 2000 LODI BOWLING <br /> 24x22 2000 CFM 302 N SACRAMENTO STREET <br /> FAU-20 DR-1 LODI CA 95240 <br /> 24x22 <br /> 2000 CFM <br /> DS-1 <br /> WIF-1 24x22 FAU-14 <br /> 2000 CFM <br /> DR-1 <br /> 24x22 <br /> —F <br /> 2000 C <br /> FAU-19 DR-1 <br /> 124x22 <br /> 2000 CFM <br /> WEF-1 �, DS-1 <br /> 24x22 <br /> 2000 CFM 2000 CF <br /> WIF-1 DS-1 DR-1 <br /> 24x22 24x22 <br /> t It <br /> FAU-17 <br /> 2000 CFM I—I <br /> DS-1 <br /> 24x22 FAU-13 TO <br /> B W <br /> 2000 CFM <br /> EE <br /> DR-1 <br /> 24x22 <br /> 2000 CFM <br /> FAU-18 DR-1 <br /> 24x22 <br /> WIF-1 2000 CFM -- k <br /> DS-1 <br /> 24x22 <br /> oo ° eH <br /> ® WEF-1 <br /> J/// N <br /> 2000 CFM <br /> DR-1 <br /> 2000 CFM 24x22 <br /> DS-1 <br /> 24x22 <br /> ° ° a FAU-12 Lt : L <br /> PROFESSIONAL STAMP <br /> S\ONAL F <br /> 5 <br /> G. <br /> e F. 0 � <br /> a of �G qL� 2 <br /> 41,1WIF-1 <br /> ' NW M29759" <br /> U) REN. 6-30=20 Q <br /> F'4"�CHA NSG�OQ� <br /> OF C <br /> REVISIONS <br /> No. Description Date By <br /> 1 MECHANICAL SECOND FLOOR PLAN <br /> SCALER/8" = 1' <br /> Project 17028 <br /> DRYER VENT SIZING brawn NR <br /> BASIS OF DES#GN -40'OF 4" STRAIGHT PIPE CONVEYTING 60 CFM � ecked GD <br /> WITH A MAXIMUM PRESSURE DROP OF 0.15' WC INCLUDING WALL By: <br /> MECHANICAL SECOND FLOOR PLAN NOTES CAP <br /> INSTALLED EQUIVALE MAX LENGTH <br /> 4"0 FLUE FROM WH-1,2 THRU ROOF PER DETAIL 5/MO, ELBOWS NTLENGTH OF DRIER <br /> PIPE <br /> 2❑ 4"0 DRYER VENT THRU WALL PER DETAIL 2/M0,1, SEE DRYER VENT PERMIT SET <br /> SIZING TABLE THIS SHEET. 4" DIAMETER PIPE 0 40 40 <br /> 8/02/18 <br /> REFRIGERANT LINES SIZED PER MANUFACTURE'S REC❑MMENDATI❑NS AND 1 6 34 <br /> 3/4"CONDUIT FROM BELOW TO CORRESPONDING FAU-, SEE M1 FOR 2 12 28 <br /> CONTINUATION, 3 18 22 JOB # 2018-061 <br /> INSTALL WEF-1 IN HIGH SECTI❑N OF ROOF. 4 24 6 <br /> 5 30 1SHEET TITLE <br /> GDMD ENGINEERING, INC MECHANICAL SECOND <br /> 5" D#AMETER PIPE 0 100 100 Mechanical and Safety Engineers FLOOR PLAN <br /> 1 6 94 212 W Pine St, Ste 4 <br /> 2 12 88 Lodi, Ca 95242 <br /> (NOT RECOMMENDED) 3 18 82 Ph 209-367-0899 <br /> (NOT RECOMMENDED) 1 4 1 24 1 16 Fax 209-367-0898 <br /> (NOT RECOMMENDED) 5 30 70 <br /> E-mail:gdmdengrinc@sbcglobal.net <br />