My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CORRESPONDENCE_1984-1989
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
CORRESPONDENCE_1984-1989
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2023 4:12:55 PM
Creation date
4/7/2023 1:44:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
CORRESPONDENCE
FileName_PostFix
1984-1989
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\cfield
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
728
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
n <br />Sect . :n No ' <br />Revision Pdo. <br />Gate. <br />Fa 9e of <br />11.0 LABORATORY ANALYTICAL PERSONNEL CERTIFICATION PROCEDURES <br />11.1 General <br />Multi -tech recognizes that the confidence in any analytical <br />rr - <br />tt�cr i s 1 irni ted if personnel have not demonstrated the ski 1'.= <br />needea to ptrf orrn the ana; i s. Therefore, l eboratorV ana l yti c.2 <br />ptrscrrti are trained in cuality control techniques a n a ase <br />required to qualify to run the analysis. <br />Certi=icaticn procedures ensure that our laboratory analytics' <br />personnel understand methods of analysis and are competent <br />performing analytical analyses under the protocols in use �d <br />Mu'.t.-.e c± . <br />11.2 Certification Procedures <br />The certification procedures for laboratory analytical personnel <br />include evaluations of precision and accuracy for each analysis <br />performed. When more than one person qualifies to do the sarre <br />test, replicate data will be compiled to validate not only <br />personnel but also the method of analysis used. Personnt' <br />demonstrate their proficiency in conducting chemical analyses by <br />analy`ing spiked standard samples prior to conducting analyses of <br />natural samples. They will be prepared by spiking dei onized water <br />with the analyte of interest at: <br />0.0 times the desired detection limit. <br />-0.5 times the desired detection limit. <br />1.0 times the desired detection limit. <br />2.0 times the desired detection limit. <br />5.0 times the desired detection limit. <br />10.0 times the desired detection limit. <br />Detection limits are calculated using the method in Section 13.0. <br />- -- - The accuracy is the slope of the best linear regression line of <br />found versus target concentration. The best linear fit regression <br />line must have a correlation coefficient of 0.996 for the <br />calculation of the detection limit and accuracy. A minimum of one <br />sample at each concentration level is analyzed each day for three <br />separate days. The precision of the method is the standard error <br />of the best fit linear regression line of the found versus tercet <br />
The URL can be used to link to this page
Your browser does not support the video tag.