Laserfiche WebLink
Ll <br />WASTE DISCHARGE REQUIREMENTS <br />FORWARD INCORPORATED <br />WASTE MANAGEMENT FACILITY <br />CLASS II LANDFILLS CLASS III LANDFILLS <br />CLASS II SURFACE IMPOUNDMENT <br />CLASS II LAND TREATMENT UNIT <br />CLOSURE OF CLASS I LANDFILL <br />SAN JOAQUIN COUNTY <br />-4- <br />petroleum hydrocarbons have dropped below those given in Discharge <br />Specification 41, the soil will be used as daily or intermediate cover. <br />14. Leachate from the landfill units and liquid wastes described in Discharge <br />Specification B.7 are proposed for discharge to WMU F, a Class II surface <br />impoundment. These wastes are classified as 'designated wastes' using the <br />criteria set forth in Subchapter 15. The location of WMU F as shown on <br />Attachment B is tentative and may be changed. This final location will <br />be specified in WMU F design and construction specifications that will be <br />submitted to the Board for approval. <br />15. WMU A was constructed in 1979 and operated until October 1984. WMU A <br />received permits necessary for construction and operation before <br />27 November 1984, the effective date of Subchapter 15. WMU A contains a <br />mixture of designated and a minor amount of hazardous wastes. Hazardous <br />waste discharge to this unit ceased in 1984. This WMU is undergoing <br />closure under the direction of the State Department of Health Services <br />(DHS). <br />16. Section 2531(b)(1) of Subchapter 15 requires that waste management units <br />for hazardous waste (Class I units) be underlain by natural geologic <br />materials which have a permeability of not more than 1x10"' cm/sec, and <br />which are of sufficient thickness to prevent vertical movement of fluid, <br />including waste and leachate, from waste management units to water of the <br />State as long as wastes in such units pose a threat to water quality. <br />17. Hydrogeologic data submitted by the Discharger indicate that WMU A, which <br />contains hazardous waste, is located in a geologic setting which does not <br />meet the siting criteria for a Class I WMU. <br />18. In a letter dated 20 October 1988, the Discharger requested approval of <br />the facility's closure plan as an engineered alternative under Section <br />2510(b) of Subchapter 15. In this letter, the Discharger demonstrated that <br />compliance with the prescriptive standard through closure by waste removal <br />would require excavation and removal of approximately 500,000 cubic yards <br />of hazardous material and cover soil. The estimated cost for disposal of <br />this material at an existing, permitted Class I landfill, such as Kettleman <br />Hills, would cost $100 to $150 million. The Discharger has demonstrated <br />