MONITORING AND REPORTING PROGRAM <br />FORWARD INCORPORATED <br />WASTE MANAGEMENT FACILITY <br />CLASS II LANDFILLS <br />CLASS III LANDFILLS <br />CLASS II SURFACE IMPOUNDMENT <br />CLASS II LAND TREATMENT UNIT <br />CLOSURE OF CLASS I LANDFILL <br />SAN JOAQUIN COUNTY <br />-13- <br />Testing for PCBs shall be conducted using composite samples collected at the <br />shredder facility. The samples shall be analyzed using EPA Method 8080. BTX&E <br />shall be measured using EPA Method 602. <br />When it is necessary to determine if a shredder waste is a 'designated waste', <br />run a Waste Extraction Test. The shredder waste is 'designated' if it exceeds <br />any of the following maximum concentrations of designated level parameters. <br />Designated Level <br />Parameter <br />Cadmium <br />Chromium VI <br />Total Chromium <br />Lead <br />Mercury <br />Nickel <br />Zinc <br />Copper <br />Maximum <br />Concentration <br />100 /jg/ 1 <br />500 Ng/l <br />560 mg/l <br />500 /lg/ 1 <br />20 /!g/ 1 <br />134 /jg/ 1 <br />200 mg/1 <br />200 mg/1 <br />Monitoring requirements for coal and wood ash accepted at Forward Inc. are as <br />follows for each waste stream: <br />Report in <br />Parameter/Constituent Units of <br />Amount of coal or wood ash <br />Cubic Yards <br />accepted <br />EC* <br />/mhos/cm <br />PH* <br />pH Units <br />TDS* <br />mg/l <br />Metals* <br />-- <br />ICAP for the following: <br />Antimony <br />mg/l <br />Barium <br />mg/l <br />Beryllium <br />mg/l <br />Cadmium <br />mg/l <br />Chromium (VI and Total) <br />mg/l <br />Sampling <br />Frequency <br />Quarterly <br />Quarterly <br />Quarterly <br />Quarterly <br />Quarterly <br />Quarterly <br />Quarterly <br />Quarterly <br />Quarterly <br />