Laserfiche WebLink
VACUUM SENSOR RELIEF VALVE PRESSURE <br /> DEVICE LABEL RELIEF VALVE PRESSURE <br /> +AAM- <br /> +AAE- <br /> 161500 <br /> JUN 14, 2023 10:48 AM <br /> TANK PRODUCT LABEL METER DATA <br /> 1 SUPREME YES <br /> 2 REGULAR YES <br /> 3 DIESEL YES <br /> 4 NO <br /> +AAM- <br /> +AAE- <br /> 190200 <br /> JUN 14, 2023 10:48 AM <br /> SOFTWARE REVISION LEVEL <br /> VERSION 335.00 <br /> SOFTWARE+ACM- 346335-100-A <br /> CREATED - 18.08.27.10.22 <br /> S-MODULE+ACM- 330160-104-a <br /> SYSTEM FEATURES: <br /> PERIODIC IN-TANK TESTS <br /> ANNUAL IN-TANK TESTS <br /> BIR <br /> ISD/APM <br /> +AAM- <br /> +AAE- <br /> I11100 <br /> JUN 14, 2023 10:48 AM <br /> CHEVRON 21247 <br /> 3400 MACARTHUR <br /> TRACY CA. <br /> PRIORITY ALARM HISTORY <br /> ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME <br /> Q 3 OTHER DIESEL PLLD SHUTDOWN ALARM CLEAR 6-14-23 9:48AM <br /> Q 3 OTHER DIESEL GROSS LINE FAIL CLEAR 6-14-23 9:48AM <br /> Q 2 OTHER REGULAR PLLD SHUTDOWN ALARM CLEAR 6-14-23 9:48AM <br /> Q 2 OTHER REGULAR GROSS LINE FAIL CLEAR 6-14-23 9:48AM <br /> Q 1 OTHER SUPREME PLLD SHUTDOWN ALARM CLEAR 6-14-23 9:47AM <br /> Q 1 OTHER SUPREME GROSS LINE FAIL CLEAR 6-14-23 9:47AM <br /> Q 3 OTHER DIESEL PLLD SHUTDOWN ALARM ALARM 6-14-23 9:29AM <br /> Q 3 OTHER DIESEL GROSS LINE FAIL ALARM 6-14-23 9:29AM <br /> Q 1 OTHER SUPREME PLLD SHUTDOWN ALARM ALARM 6-14-23 9:24AM <br /> Q 1 OTHER SUPREME GROSS LINE FAIL ALARM 6-14-23 9:24AM <br /> Q 2 OTHER REGULAR PLLD SHUTDOWN ALARM ALARM 6-14-23 9:20AM <br /> Q 2 OTHER REGULAR GROSS LINE FAIL ALARM 6-14-23 9:20AM <br /> L 4 ANNULAR REGULAR TANK ANNULAR SENSOR OUT ALARM CLEAR 6-14-23 9:10AM <br /> L 8 PIPE DIESEL FILL SUMP SENSOR OUT ALARM CLEAR 6-14-23 9:10AM <br /> L 1 ANNULAR SUPREME-DSL TANK ANN SENSOR OUT ALARM CLEAR 6-14-23 9:10AM <br /> L 3 PIPE SUPREME FILL SUMP SENSOR OUT ALARM CLEAR 6-14-23 9:10AM <br /> Q 3 OTHER DIESEL PLLD SHUTDOWN ALARM CLEAR 6-14-23 9:10AM <br /> L 7 STP SUMP DIESEL STP SUMP SENSOR OUT ALARM CLEAR 6-14-23 9:10AM <br /> Q 1 OTHER SUPREME PLLD SHUTDOWN ALARM CLEAR 6-14-23 9:10AM <br /> L 2 PIPE SUPREME STP SUMP SENSOR OUT ALARM CLEAR 6-14-23 9:10AM <br /> L 6 PIPE REGULAR FILL SUMP SENSOR OUT ALARM CLEAR 6-14-23 9:10AM <br /> Q 2 OTHER REGULAR PLLD SHUTDOWN ALARM CLEAR 6-14-23 9:10AM <br /> Lll DISP PAN DISPENSER 3-4 SUMP SENSOR OUT ALARM CLEAR 6-14-23 9:10AM <br /> L 5 STP SUMP REGULAR STP SUMP SENSOR OUT ALARM CLEAR 6-14-23 9:10AM <br /> L10 DISP PAN DISPENSER 1-2 SUMP SENSOR OUT ALARM CLEAR 6-14-23 9:10AM <br /> L 9 PIPE VENT SUMP SENSOR OUT ALARM CLEAR 6-14-23 9:10AM <br /> L13 DISP PAN DISPENSER 7-8 SUMP SENSOR OUT ALARM CLEAR 6-14-23 9:10AM <br /> L12 DISP PAN DISPENSER 5-6 SUMP SENSOR OUT ALARM CLEAR 6-14-23 9:10AM <br />