Laserfiche WebLink
SAN J 0 A Q I I I Irl Environmental Health Department <br /> CCUN r <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> JAMAR SERVICE 4075 E MAIN ST, STOCKTON May 09, 2023 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 210 CCR 2715(c)Failure to provide initial training,train every 12 months, and have a trained employee present. <br /> OBSERVATION: The designated operator employee training for all employees was expired. The most recent <br /> training record was for training conducted in March 2022 for one employee. <br /> REGULATION GUIDANCE: The designated operator shall train facility employees in the proper operation and <br /> maintenance of the UST system at least once every 12 months. The training shall be conducted before the <br /> individual performs the duties of a facility employees.The training shall include, but is not limited to: <br /> 1. Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br /> 4. Name of the contact person(s)for emergencies and monitoring equipment alarms <br /> Initial training shall also include a site-specific practical demonstration that provides both sharing information and <br /> evaluating knowledge for responding to emergencies, leak detection, monitoring alarms, spills and overfills. At least <br /> one of the facility employees present during operating hours shall have current training. <br /> CORRECTIVE ACTION: Ensure that employees have been trained by the designated operator, maintain the list on <br /> site, and submit a copy of the training records to the EHD. <br /> This is a repeat violation, Class II. <br /> 214 CCR 2712 Failure to comply with UST operating permit conditions. <br /> OBSERVATION: Notification was made to the EHD for the following repair work and the site failed to comply with <br /> the permitting requirements: <br /> -Notification was received from Elite IV on 8/9/22 for replacement of the 87 relay on 8/9/22. <br /> -Notification was received from Elite IV on 11/22/22 for a cold start of the monitoring panel on 11/21/22. <br /> No work orders, test results,or other documentation was found on site for these repairs. <br /> REGULATION GUIDANCE: Emergency repairs relating to UST system monitoring and release detection may be <br /> performed by a properly licensed,trained, and certified contractor pursuant to the EHD's policy and a permit <br /> obtained within one business day from the EHD. All other repairs must have a permit submitted to and approved by <br /> the EHD prior to beginning work. For EHD Notification &On-site Paperwork only permitting, the following is <br /> required: <br /> a) Provide 48-hour written notification to ust@sjgov.org for repair and testing. <br /> b)The component must be tested after repair/installation to verify functionality. <br /> c)The service company must provide the following documentation to the tank owner/operator for on-site review <br /> by an inspector during the annual UST inspection: <br /> 1) Description of part(s)installed (parts list, cut sheets, etc.) <br /> 2) Proof of current ICC and manufacturer certifications for individual performing the work <br /> 3)Testing documentation to verify functionality of the component after repair <br /> If a required permit is not obtained or all conditions are not met, a"Failure to Obtain a Permit"penalty(an additional <br /> 100%of the full retrofit/repair permit fee)will apply. <br /> CORRECTIVE ACTION: Immediately obtain a permit from the EHD for the replacement of the 87 relay and the cold <br /> start of the monitoring panel. A"Failure to Obtain a Permit" penalty applies. <br /> This is a minor violation. <br /> FA0002121 PR0231667 SCO01 05/09/2023 <br /> EHD 23-01 Rev.12/06/2021 Page 7 of 8 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />