Laserfiche WebLink
ut" -o Body Art Inspes Report <br /> San Joaquin County Environmental Health Department Date: <br /> 1868 E.Hazelton Ave.,Stockton,CA 95205 Program <br /> (209)468-3420 Record: <br /> IYoR � www.siogv.org/ehd Program <br /> Element: <br /> PR Number PRACTITIONER/ARTIST NAME PR Number PRACTITIONER/ARTIST NAME <br /> PRO523951 Melissa Santos <br /> PR0537373 Jonathan Santos <br /> PRO537371 Daniel Ju e <br /> PR0537369 Michael Wright <br /> Observations and Corrective Actions: <br /> 1. Each sterilization load shall be monitored with mechanical indicators for time, temperature and pressure, Sterilization shall be <br /> accomplished by steam autoclave, manufactured for the sterilization of medical instruments,and pass a Class V integrator test. <br /> HSC 119315(b) <br /> 2. Instruments or other reusable items shall be placed in a basin of water or cleaned, decontaminated, packaged, and sterilized <br /> immediately after each procedure. HSC 119309 <br /> If not being processed for immediate use, clean instruments shall be placed in sealed sterilization package that contains <br /> process indicator, name of instrument, date sterilized, and initial of person/operator. HSC 119315(a) <br /> 4. Sterilizer shall be spore-tested after initial installation, after major repair, and at least once per month. A written sterilization <br /> shall be maintained for 3 years. The log shall include spore-test results each sterilization cycle, date, contents, exposure time and <br /> temperature, results of the Class V integrator for every cycle/load, and evidence of a acceptable spore test before reuse of the <br /> sterilizer after a failed spore-test. HSC 119315(b) <br /> 5. Decontamination and sterilization areas shall be separated from procedure areas by a space of at least 5 feet or by a <br /> cleanable barrier and equipped with a sink with hot and cold running water, containerized liquid soap, and single use paper <br /> towels dispensed from a wall-mounted, touchless dispenser that is readily accessible to practitioner. HSC 119314(c) <br /> 6. A facility that uses single use instruments shall maintain record of purchase, log of procedures, names of practitioner and <br /> client, date of procedure, instruments used, and written evidence from the manufacture that the instruments have undergone <br /> sterilization. The record of purchase, evidence of sterilization, type and number of instruments used shall be maintained for a <br /> minimum of 90 days after use. HSC 119315(f) <br /> 18. The facilities client consent form and medical questionnaire must include all of the information listed in Form B, and are <br /> available for inspection. HSC 119303 <br /> 19. At the completion of the procedure, the practitioner shall provide postprocedure instructions that include all elements listed in <br /> Form B. HSC 119308(b) <br /> 26. Any part of a tattooing machine that may touch the practitioner during procedure shall be covered with a disposable plastic <br /> sheath. HSC 119311(h) <br /> 9. No food, drink, tobacco product, or personal effects are permitted in the procedure area. HSC 119309 <br /> Corrective Action, unless otherwise noted, is due within 30 days <br /> Reinspecion on/about: A reinspection fee of$125 per hour may charged. Page 2 of 2 <br /> EH-04/2014 <br />