Laserfiche WebLink
Body Ins can Re 4I-)A�Is <br /> Y Art P Port Date: <br /> ?� San Joaquin County Environmental Health Department Program <br /> 1868 E.Hazelton Ave.,Stockton,CA 95205 Record: PA�US7,34St <br /> i (209)468-3420 Prog L4 1 l <br /> wwwsioqv.org/ehd Element: <br /> PR Number PRACTITIONER/ARTIST NAME PR Number PRACTITIONER/ARTIST NAME <br /> PR0523951 Melissa Santos <br /> PR0537369 Michael Wright-1313P <br /> PRO537371 Daniel Juga-13131P <br /> Observations and Corrective Actions: <br /> 1. Each sterilization load shall be monitored with mechanical indicators for time, temperature and pressure, Sterilization shall be <br /> accomplished by steam autoclave, manufactured for the sterilization of medical instruments, and pass a Class V integrator test. <br /> HSC 119315(b) <br /> 3. Sterilizer shall be loaded, operated, decontaminated, and maintained according to manufacturer's recommendations. HSC <br /> 119315(b) <br /> 4. Sterilizer shall be spore-tested after initial installation, after major repair, and at least once per month. A written sterilization <br /> shall be maintained for 3 years. The log shall include spore-test results each sterilization cycle, date, contents, exposure time and <br /> temperature, results of the Class V integrator for every cycle/load, and evidence of a acceptable spore test before reuse of the <br /> sterilizer after a failed spore-test. HSC 119315(b) <br /> 5. Decontamination and sterilization areas shall be separated from procedure areas by a space of at least 5 feet or by a <br /> cleanable barrier and equipped with a sink with hot and cold running water, containerized liquid soap, and single use paper <br /> towels dispensed from a wall-mounted, touchless dispenser that is readily accessible to practitioner. HSC 119314(c) <br /> 6. A facility that uses single use instruments shall maintain record of purchase, log of procedures, names of practitioner and <br /> client, date of procedure, instruments used, and written evidence from the manufacture that the instruments have undergone <br /> sterilization. The record of purchase, evidence of sterilization, type and number of instruments used shall be maintained for a <br /> minimum of 90 days after use. HSC 119315(f) <br /> 7. The sharps waste container shall be within arm's reach and labeled with the word"sharps waste"or with the biohazard symbol <br /> and the word"Biohazard". Sharp waste containers shall be disposed by a licensed waste hauler or approved mail back system. <br /> Documentation of proper disposal shall be maintained for 3 years. HSC 119314(e) <br /> 9. No food, drink, tobacco product, or personal effects are permitted in the procedure area. HSC 119309 <br /> 11. The procedure area shall be equipped with a sink with hot and cold running water, containerized liquid soap, and single use <br /> paper towels dispensed from a wall-mounted, touchless dispenser that is readily accessible to practitioner. HSC 119314(b) <br /> 13. Practitioner shall provide evidence of a completed, EHD approved, OSHA Bloodborne Pathogen Training consistent with <br /> section 119307. <br /> 18. The facilities client consent form and medical questionnaire must include all of the information listed in Form B, and are <br /> available for inspection. HSC 119303 <br /> 19. At the completion of the procedure, the practitioner shall provide postprocedure instructions that include all elements listed in <br /> Form B. HSC 119308(b) <br /> Reinspecion on/about: A reinspection fee of$130 per hour may be charged. Page 2 of 3 <br /> EH-03/2015 <br />