My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
430
>
2300 - Underground Storage Tank Program
>
PR0231425
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/17/2024 11:19:01 AM
Creation date
4/26/2023 9:51:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0231425
PE
2361
FACILITY_ID
FA0003838
FACILITY_NAME
Frontier California Inc.: Manteca CO
STREET_NUMBER
430
Direction
W
STREET_NAME
CENTER
STREET_TYPE
St
City
Manteca
Zip
95336
APN
21721070
CURRENT_STATUS
01
SITE_LOCATION
430 W Center St
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\lsauers1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
nteg rated solution for centralized , <br /> single system site monitoring . <br /> Standard Models <br /> Console Form Number: 848290-022 <br /> Description: TLS-350 Plus monitoring console with integral printer <br /> Console Form Number: 848290-002 <br /> Description: TLS-350 Plus monitoring console without integral printer <br /> Console Form Number: 848291 -021 <br /> Description: TLS-350 Plus PC version without printer, keyboard or display <br /> TLS=350 Plus Interface Modules <br /> The TLS-350 Plus monitoring console contains three compartments in which individual interface modules can be installed. Interface modules <br /> may be factory-installed in the console upon initial ordering, or ordered separately as spare modules to expand an existing system. <br /> Form No. <br /> Factory <br /> Installed <br /> Modules Description Feature Compatibility (where applicable) <br /> LOW-POWER COMPARTMENT (Limit eight per console, unless otherwise noted) <br /> 329356-002 Four-Input Probe Interface Module (Maximum three per Series 8473 0. 1 GPH Magnetostrictive Probe <br /> console. Includes terminal connector for one ground <br /> temperature thermistor for the volumetric line leak detector). <br /> 329358-001 Eightdriput Interstitial/Liquid Sensor Series 7943 Interstitial Sensor for Fiberglass Tanks and <br /> Interstitial Sensor for Steel Tanks <br /> Series 7943 Piping Sump Sensor <br /> 329357-001 Five-Input Vapor Sensor Interface Module Series 7943 Vapor Sensor <br /> 329399-001 Five-Input Groundwater Sensor Module 4SITE Series 7943 Groundwater Sensor <br /> 329956-001 Eight-Input Type A Sensor Interface Module 4SITE Series 7943 Discriminating Interstitial Sensor <br /> 329950-001 Six-Input Type B Sensor Interface Module 4SITE Series 7943 Discriminating Dispenser <br /> 330843-001 Six-Input Pressurized Line Leak Interface Series 8484 Pressurized Line Leak Detection System <br /> Module (One per console) Requires TLS-350 Plus version 7.0 or higher software <br /> HIGH-POWER COMPARTMENT (Limit eight per console, unless otherwise noted) <br /> 329359-001 Four-Relay Output Interface Module <br /> 329360-001 Two-Input/Two-Relay Output Interface Module <br /> 329999-001 Pump Sense Interface Module Accepts up to four inputs. <br /> 330374-001 Three-Output Pressurized Line Leak Series 8484 Pressurized Line Leak Detection System <br /> Controller Interface Module (Two per console) Requires TLS-350 Plus version 7.0 or higher software <br /> COMMUNICATIONS COMPARTMENT (Limit three per console, unless otherwise noted) <br /> 330149-002 SiteFax Interface Module Allows hookup to most remote facsimile, modem or teletype <br /> equipment. Requires TLS-350 Plus version 3.0 or higher software. <br /> 330586-001 RS485/232 Dual Port Communications Module (Slot 4 only) <br /> 330148-001 RS-232 Interface Module with Auxiliary Port Provides two 25-pin D-connectors for data transmission to <br /> P.O.S. terminal, printing device or computer <br /> 329362-001 RS-232 Interface Module Provides a 25-pin D-connector for data transmission to <br /> P.O.S. terminal, printing device, or computer <br /> 330000-001 Remote Printer Interface Module Provides a 25-pin D-connector for data transmission <br /> to a remote serial printer <br /> 330883-001 WPLLD Communications Module <br /> (Maximum one per console) <br /> 330020-425 Ethernet — TCP/IP Communications module Provides connectivity to local and wide area networks (LAN/WANS) <br /> Specifications <br /> Operating Temperature Range 32°F to 118°F (0°C to 45°C) For more information call <br /> Storage Temperature Range 15°F to 118°F ( 10°C to 45°C) 1 - 888-561 - 7942 <br /> VEEDER— ROOT Q 2003 Veeder-Root Company • 125 Powder Forest Drive • Simsbury, CT 06070 • USA <br /> Telephone: 860-651-2700 Fax : 860-651-2719 www.veeder.com <br /> 1111111111104!�• <br /> VR 13679 P/N 0576047-022 Rev.D VRLP 8/2003 Printed in USA <br />
The URL can be used to link to this page
Your browser does not support the video tag.