Laserfiche WebLink
A NJ O A Q U l N Environmental Health Department <br /> COUNTY— <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Fe:NATIONAL PETROLEUM MANTECA 2072 W YOSEMITE AVE, MANTECA ptember 05, 2023 <br /> Single-Walled Non-Pressurized Piping <br /> 404 CCR 2643(e),2661(f) Failure to conduct 0.1 gph test on single-walled gravity piping biennially or post repair(pre-1984) ❑V ❑R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 104 CCR 2632(d)(1), 2634(d)Failure to submit a complete and accurate UST Monitoring Plan. <br /> OBSERVATION: The monitoring plan is not current and/or not approved by the EHD. <br /> 1. The monitoring plan for the Biodiesel 20 tank incorrectly list the leak detector Manufacturer and model as"Fe <br /> Petro/STP MLD". The leak detector on site is VMI -99LD2000. <br /> 2. The monitoring plan for the Racing fuel 100 tank incorrectly list the leak detector Manufacturer and model as VMI <br /> -99LD2000.The leak detector on site is Fe Petrol/STP MLD <br /> REGULATION GUIDANCE: The monitoring plan must be uploaded to the California Environmental Reporting <br /> System (CERS). <br /> CORRECTIVE ACTION: Immediately log into CERS, make the necessary changes, and submit for review by the <br /> EHD. <br /> This is a minor violation. <br /> 112 CCR 2638, 26410),2715(f) Failure to have properly qualified service technician test leak detection equipment every <br /> 12 months. <br /> OBSERVATION: The racine fuel 100 and 110 tanks annual leak detector testing were last performed on 01/29/2020 <br /> and were due by 09/2021, 09/2022 and 09/2023. Testing has not been completed and is 45 months past due. <br /> REGULATION GUIDANCE: These tests are required once every 12 months. <br /> CORRECTIVE ACTION: Immediately schedule these tests and provide 48 hours notification to the EHD. Please be <br /> aware that all EHD staff time associated with a follow up inspection will be billed at our current hourly rate($156). <br /> This is a repeat violation, Class II. <br /> 202 CCR 2712(i) Failure to retain a paper or electronic copy of the permit to operate at the facility. <br /> OBSERVATION:A copy of the UST operating permit was not found on site. <br /> REGULATION GUIDANCE:A copy of the UST operating permit and all attachments and conditions shall be <br /> retained at the facility. <br /> CORRECTIVE ACTION: Immediately obtain a copy of the permit and retain it on site. <br /> This is a repeat violation, Class II. <br /> FA0004625 PR0231426 SCO01 09/05/2023 <br /> EHD 23-01 Rev.12/06/2021 Page 4 of 7 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />