My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1048
>
2300 - Underground Storage Tank Program
>
PR0231462
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/22/2023 11:31:35 AM
Creation date
6/20/2023 8:50:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0231462
PE
2361
FACILITY_ID
FA0000508
FACILITY_NAME
7- ELEVEN INC # 17647
STREET_NUMBER
1048
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
21903003
CURRENT_STATUS
01
SITE_LOCATION
1048 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
80
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br />Overfill Prevention Equipment Inspection Report <br />OVERFILL PREVENTION EQUIPMENT DETAILS <br />Tank ID (one OPE per column) <br />Regular Premium <br />Are both vent and tank riser piping <br />secondarily contained? <br />a Yes <br />r No <br />a Yes <br />r No <br />r Yes <br />r No <br />C Yes <br />r No <br />OPE Model OPW OPW <br />What is the OPE response when activated? <br />(Check all that apply) <br />P. Shut off <br />Flow <br />r Restricts <br />Flow <br />r Audible <br />Alarm <br />r Visual <br />Alarm <br />F.?. Shut off <br />Flow <br />r Restricts <br />Flow <br />E Audible <br />Alarm <br />r Visual <br />Alarm <br />E Shut off <br />Flow <br />r Restricts <br />Flow <br />E Audible <br />Alarm <br />r Visual <br />Alarm <br />1--- Shut off <br />Flow <br />r Restricts <br />Flow <br />r Audible <br />Alarm <br />r Visual <br />Alarm <br />Are flow restrictors installed on vent piping <br />that may interfere with the OPE operation? <br />r Yes* <br />a No <br />r Yes* <br />a No <br />r Yes* <br />r No <br />r Yes* <br />r No <br />At what level in the tank is the OPE set to <br />activate? (Inches from bottom of tank) 80.25 79.875 <br />What is the percent capacity of the tank at <br />which the OPE activates? 94.8 94.5 <br />Is the OPE in proper operating condition to <br />respond when the stored substance reaches <br />the designated regulatory level? <br />a Yes <br />C No <br />a Yes <br />r No <br />r Yes <br />c No <br />r Yes <br />r No <br />SUMMARY OF TESTING RESULTS <br />OPE Inspection Results <br />a Pass <br />r Fail <br />a Pass <br />r Fail <br />r Pass <br />r Fail <br />r Pass <br />r Fail <br />COMMENTS <br />Describe all results marked "Fail" and each proposed remedy. <br />*Mark here if: <br />I— Flow restrictors interfere with overfill prevention and equipment repairs required. <br />Additional copies of this page may be attached. <br />Attach tank chart(s), measurements, calculations, and In-Tank Setup report(s)