COMPLIANCE INFO_2023
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231435
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/17/2024 11:23:47 AM
Creation date
6/20/2023 9:28:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0231435
PE
2361
FACILITY_ID
FA0000916
FACILITY_NAME
7-ELEVEN INC #19976
STREET_NUMBER
1399
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21633034
CURRENT_STATUS
01
SITE_LOCATION
1399 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\lsauers1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
87
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Overfill Prevention Equipment Inspection <br /> . :Tanknology DPW 61 and 71 Series Overfill Prevention Device Inspection <br /> Date: 10/13/2023 <br /> Customer Name: 7-ELEVEN,INC. <br /> Location#: 7-ELEVEN#19976, MKT 2368 <br /> Location Address: 1399 N.MAIN ST.@ NORTH GATE,MANTECA,CA,95336 <br /> OPW Model Number: 71-SO <br /> T5:PREMIUM T4:UNLEADE <br /> PART 1)Proper height setting calculation <br /> Maximum Tank Volume per:Tank Chart Agallons 9684.000 14781.000 <br /> Max shut off requirement for Flapper is 95% B 95% 0.95 0.95 0.95 0.95 <br /> Multiply Maximum tank volume by 95% Cgallons 9199.800 14041.950 <br /> Use tank chart to determine height of calculated volume D inches 80.375 <br /> Measure top of fill riser threads,or face seal adapter when used,to tank top E inches 27.750 <br /> Tank diameter From Chart F inches 89.750 <br /> Upper Tube in tank(G) F-D=G G inches 9.375 <br /> Subtract 2 inches from upper tube in tank G-2"=H H inches 7.375 <br /> Calculated minimum upper tube length(1)H+E=I i inches 35.125 <br /> Actual measured upper tube length (Without fill <br /> finches 36.500 <br /> adapter)(J) <br /> PART 2)Device certification criteria evaluation <br /> Criteria 1 Yes <br /> Does the overfill prevention device meet the 95%requirement? <br /> Criteria 1 a If the final shutoff volume is installed greater than 95%,is there at <br /> least 250 gallons of ullage above the overfill device activation point NA <br /> to ensure that none of the tank top fittings are exposed to product, <br /> meeting the criteria established in EPA 280.20iic and per OPW <br /> installation guidelines. <br /> Criteria 2 Is the Actual measured upper tube length 6.5 inches Yes <br /> or more than the fill riser?(J must be 6.5"or more <br /> than E) <br /> Criteria 3 Does the overfill prevention device function as <br /> required?(Inspect the device for damage, Yes NA-seized <br /> contamination,freedom of movement, <br /> weakening due to wear and corrosion) <br /> PART 3)Device Certification PASS/FAIL <br /> Pass NA-seized <br /> Technician certifies that the device is operationally <br /> compliant. <br /> Comments: <br /> was not able to remove drop tube on REG.only PREM.was called into the office.. <br /> Signature of Technician: Date: <br /> 10/13/2023 <br /> Jesus Saldivar <br /> WO: NW1-2362812 <br />
The URL can be used to link to this page
Your browser does not support the video tag.