COMPLIANCE INFO_2023
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
U
>
UNION
>
940
>
1600 - Food Program
>
PR0360326
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/10/2023 2:21:00 PM
Creation date
7/10/2023 2:20:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0360326
PE
3611
FACILITY_ID
FA0001406
FACILITY_NAME
UNION COURT APARTMENTS
STREET_NUMBER
940
Direction
S
STREET_NAME
UNION
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
21902034
CURRENT_STATUS
01
SITE_LOCATION
940 S UNION RD
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Time In: <br />10:18 am <br /> 9:30 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: Owner/Operator: UNION COURT LTD PARTNERSHIP <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 940 S UNION RD, MANTECA 95336 <br />Date: 07/05/2023Name of Facility: UNION COURT APARTMENTS <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #9 Ladders and Handrails <br />OBSERVATIONS: Single handrail is unsecured. Secure handrail today. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #19 Depth Markers <br />OBSERVATIONS: The perimeter of the pool is lacking the depth markers. As pool water depth is 6 Ft and shallower, <br />universal " NO DIVING" symbol shall be installed on the deck directly adjacent to the depth markers. Provide depth markers <br />and universal " NO DIVING" symbol in 4 weeks. <br />CALCODE DESCRIPTION: Depth markers shall be clearly marked in the following locations: at maximum depth, at minimum depth, at <br />each end, on both sides at each end, at the slope break, and along the perimeter of the pool at distances not to exceed 25 feet. Depth <br />markers shall be 4 inches high in a contrasting color and be marked in units of feet and inches. For pool water depths 6 feet and <br />shallower, markers with universal "NO DIVING" symbol shall be installed on the deck directly adjacent to the depth markers. (CBC 3110B) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: One of the pool skimmers is lacking float valve. Provide float valve in 1 week. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br /> #38 Filter Cleaning and Maintenance <br />OBSERVATIONS: Difference between Influent and Effluent pressure is more than 10 PSI. Back wash the filter today. <br />CALCODE DESCRIPTION: All filters shall be maintained in accordance with manufacturer's specifications. (CBC 3123B) Pressure gauge <br />located on the filter shall be marked with the clean startup reading. (CBC 3125B) Each filter vessel shall be provided with valves so that it <br />can be isolated from the recirculation system for repairs and backwashing. (CBC 3128B) <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0001406 PR0360326 SC001 07/05/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.