Laserfiche WebLink
www.hilti.us Profis Anchor 2.8.7 <br />Input data and results must be checked for agreement with the existing conditions and for plausibility! <br />PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan <br />Company: <br />Specifier: <br />Address: <br />Phone I Fax: <br />E-Mail: <br />ABS Consulting <br />T. Rich <br /> | <br />Page: <br />Project: <br />Sub-Project I Pos. No.: <br />Date: <br /> <br />5 <br />Leprino Foods Tracy <br />10/7/2020 <br /> <br />5 Combined tension and shear loads <br /> <br /> bN <br /> <br /> bV <br /> z <br /> Utilization bN,V [%] <br /> Status <br />0.038 0.028 5/3 1 OK <br />bNV = bz <br />N + bz <br />V <= 1 <br />6 Warnings <br />• The anchor design methods in PROFIS Anchor require rigid anchor plates per current regulations (ETAG 001/Annex C, EOTA TR029, etc.). This <br /> means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be <br /> sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Anchor calculates the minimum required anchor plate <br /> thickness with FEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid anchor plate <br /> assumption is valid is not carried out by PROFIS Anchor. Input data and results must be checked for agreement with the existing conditions and <br /> for plausibility!  <br />• Condition A applies when supplementary reinforcement is used. The Φ factor is increased for non-steel Design Strengths except Pullout Strength <br /> and Pryout strength. Condition B applies when supplementary reinforcement is not used and for Pullout Strength and Pryout Strength. Refer to <br /> your local standard. <br />• Refer to the manufacturer's product literature for cleaning and installation instructions. <br />• Checking the transfer of loads into the base material and the shear resistance are required in accordance with ACI 318 or the relevant standard! <br />• An anchor design approach for structures assigned to Seismic Design Category C, D, E or F is given in ACI 318-14, Chapter 17, Section <br /> 17.2.3.4.3 (a) that requires the governing design strength of an anchor or group of anchors be limited by ductile steel failure. If this is NOT the <br /> case, the connection design (tension) shall satisfy the provisions of Section 17.2.3.4.3 (b), Section 17.2.3.4.3 (c), or Section 17.2.3.4.3 (d). The <br /> connection design (shear) shall satisfy the provisions of Section 17.2.3.5.3 (a), Section 17.2.3.5.3 (b), or Section 17.2.3.5.3 (c). <br />• Section 17.2.3.4.3 (b) / Section 17.2.3.5.3 (a) require the attachment the anchors are connecting to the structure be designed to undergo ductile <br /> yielding at a load level corresponding to anchor forces no greater than the controlling design strength. Section 17.2.3.4.3 (c) / Section 17.2.3.5.3 <br /> (b) waive the ductility requirements and require the anchors to be designed for the maximum tension / shear that can be transmitted to the <br /> anchors by a non-yielding attachment. Section 17.2.3.4.3 (d) / Section 17.2.3.5.3 (c) waive the ductility requirements and require the design <br /> strength of the anchors to equal or exceed the maximum tension / shear obtained from design load combinations that include E, with E increased <br /> by w0. <br />• Hilti post-installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions (MPII). Reference ACI <br /> 318-14, Section 17.8.1. <br />• The characteristic bond resistances depend on the return period (service life in years): 50 <br />Fastening meets the design criteria!