My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WAGNER HEIGHTS
>
3400
>
3600 - Recreational Health Program
>
PR0360604
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/21/2023 3:48:32 PM
Creation date
7/21/2023 3:48:16 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0360604
PE
3612
FACILITY_ID
FA0001943
FACILITY_NAME
OCONNOR WOODS RETIREMENT COMMUNITY
STREET_NUMBER
3400
STREET_NAME
WAGNER HEIGHTS
City
STOCKTON
Zip
95209
APN
08039014
CURRENT_STATUS
01
SITE_LOCATION
3400 WAGNER HEIGHTS
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Time In: <br />10:15 am <br /> 9:30 am <br />Time Out: <br />Program Element: 3612 - PUBLIC POOL/SPA - ADDITIONAL <br />Telephone: (209) 956-3400 Owner/Operator: OCONNOR WOODS HOUSING CORP <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 3400 WAGNER HEIGHTS , STOCKTON 95209 <br />Date: 07/13/2023Name of Facility: OCONNOR WOODS RETIREMENT COMMUNITY <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #10 Disinfectant Residual MAJOR <br />OBSERVATIONS: The chlorine at the spa was greater than 14 ppm. Maintain chlorine between 3-10 ppm when operating. <br />Corrected on site, neutralizer was added and it was 10 ppm. <br />CALCODE DESCRIPTION: Public pools, when open or in use, shall be disinfected continuously by approved chemicals and shall maintain <br />the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with cyanuric acid <br />or 2.0 ppm bromine. Spas, wading pools, and spray grounds shall maintain the following concentrations: 3.0 ppm to 10.0 ppm free <br />chlorine or 4.0 ppm bromine. (CCR 65529) <br /> #2 Pool Enclosure <br />OBSERVATIONS: Observed wooden beam not secured on fence. Repair/replace within 1 week. <br />CALCODE DESCRIPTION: Pool area shall be enclosed by one or more of the following: a fence, portion of a building, wall, or other <br />approved durable enclosure. Pool enclosure shall be constructed over a hard permanent material equivalent to concrete and shall be <br />installed no more than 2 inches above the finished grade. Holes, gaps, or openings in the enclosure shall not allow the passage of a <br />4-inch diameter sphere. Doors, openable windows, or gates of living quarters shall not be permitted as part of the pool enclosure. (CBC <br />3119B) Pool operator shall keep the pool enclosure well maintained. (CCR 65535) Pool enclosure shall have a minimum effective <br />perpendicular height of 5 feet and shall be constructed so that it cannot be climbed by small children. Horizontal members shall be spaced <br />at least 48 inches apart. No planters or other climbable structures shall be permitted within 5 feet of the pool enclosure or within a 5-foot <br />arc. Chain link openings shall not be larger than 1 3/4 inches when measured horizontally. Pool enclosures with a height of 4 or more feet <br />are allowed if the enclosure was constructed prior to July 1994. (CBC 3119B) <br /> #3 Safety Signs <br />OBSERVATIONS: Lacking Keep Closed sign on gate at spa enclosure. Provide sign today. <br />CALCODE DESCRIPTION: Pool operator shall keep safety signs well maintained. (CCR 65535) Safety signs shall have clearly legible <br />letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall, pole, gate, or similar <br />permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 3120B) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: The o-ring was damaged. Replace o-ring today. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0001943 PR0360604 SC001 07/13/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.