33 ELECT PENETRATION SUMP SHIELD42" MULTIPORT MANHOLE W/ <br /> 48"0 DOUBLE WALL F.R.P. <br /> BOOT BRINE INTERSTITIAL SENSOR 58 9 LIQUID TIGHT$VAPOR TIGHT FILL <br /> 3 CONTAINMENT SUMP WITH BOX <br /> REDUCING LIDQ <br /> 0 o a 7 <br /> g CIE <br /> 42" MULTIPORT MANHOLE — 3 — <br /> SUMP LIQUID SENSOR ° <br /> 58 INSTALL AT LOWEST POINT TO BRAVO FILL PORT <br /> ENSURE LIQUID DETECTION AT — <br /> FI I EARLIEST POSSIBLE MOMENT JUNCTION BOX / <br /> 10 4"TOP SEAL ADAPTOR GAP <br /> 2" F.R.P.VENT LINE TO VENT SUMP PENETRATION BOOT / O <br /> \ SUMP FUEL SWIVEL ADAPTOR <br /> 3/4"CONDUIT FROM ANNULAR <br /> SPACE MONITOR JUNCTION BOX I I <br /> 1 - - - - - 1" MIN.CLR TO SUMP <br /> SUMP PENETRATION 0 <br /> / BOOT 3/4"CONDUIT TO TURBINE 33 I I 2" IN 3"CONDUIT PRESSURE LINE <br /> INTER ITIAL ° 2" BELLxMALE F.R.P. SUMP JUNCTION BOX =__ I I OPEN FORE ECT BUMP,TO TURBINE PRIMARY MONLINE <br /> THREADED ADAPTOR <br /> SUMP I I WIRES. <br /> 3 <br /> SENSOR. " <br /> COUPLING OVER 2"F.R.P.VENT LINE K12 Architects, Inc <br /> � <br /> 2"x18"FLEXIBLE CONNECTOR I T I 3 DOUBLE WALL 3090 Fite Circle, #104 <br /> `� MALE SWIVELxMALE — — CONTAINMENT SUMP Sacramento, CA 95827 <br /> 3"OVER 2'FOR <br /> MONITORING AND BRAVO TEST PORT WITH I PH:(916)455-6500 FAX:(916)455-8100 <br /> ELECT$VACUUM. 16 I WITH TOP PLUG INC HOSE CONNECTION CAP <br /> TO TURBIN SUMP. 2"BELLxMALE F.R.P. LL CONSULTANTS: <br /> THREADED ADAPTOR FIBERGLASS CONTAINMENT SUMP TO <br /> TANK COLLAR INSIDE AND OUT TO <br /> D I ESEL FILL - P LAN VIEW EXTRACTOR FITTING 16 WITH STL PLUG AT TOP INSURE WATER TIGHTNESS <br /> 9 I I I <br /> SCALE: 3/4" = V-0- <br /> LIQUID SENSOR INSTALL AT I I <br /> VENT SUMP 40 <br /> CONTRACTOR TO LOWEST POINT TO ENSURE <br /> 58 I <br /> PROVIDE RIGID PIPE TO LIQUID DETECTION AT EARLIEST <br /> SUMP INTERSTITIAL EA.VENT RECOVERY POSSIBLE MOMENT I <br /> 58 SENSOR MANIFOLD SEE DETAIL 18/F55.0 I I 4"ALUMINUM FILL TUBE w/ <br /> I I 11 POSITIVE SHUT OFF DEVICE: <br /> < I INSTALL AT 95%OF TANK CONTRACTOR: <br /> 1"ELECT CONDUIT SEAL ALL OPENINGS I CAPACITY <br /> WATER TIGHT I I <br /> 5�� I <br /> SUMP LIQUID SENSORS: IF THESE ARE MOUNTED IN A SLEEVE OR TUBES,THAT ARE TANK LEVEL MONITOR 55 <br /> TO BE CONSTRUCTED AND INSTALLED SO THAT THE SENSOR WILL HAVE THE I i NOTES: <br /> ABILITY TO DETECT A LEAK AT THE EARLIEST OPPORTUNITY.THE SLEEVE OR TUBE AT SUMP PENETRATION <br /> SHALL NOT BE TIGHT AGAINST THE BOTTOM.GUT END AT AN ANGLE OR WITH 45 BLACK I I 1. PERPENDICULAR PENETRATIONS OF CONTAINMENT SUMPS PREFERRED, <br /> NOTCHES SO LIQUID IS ABLE TO GET TO THE SENSOR IMMEDIATELY. ___— IRON ELBOW I I 15 MAXIMUM ALLOWABLE PENETRATION ANGLE. <br /> FOR DEPTH SEE 2"x24"FLEXCONNECTOR I I 2. USE SUMP PENETRATION BOOTS AT ALL PENETRATIONS OF SUMP. PROJECT: <br /> PIPING NOTES ON � � I <br /> FS2.1 HYDROSTATIC SUMP I 3• ALL JUNCTION BOXES ARE TO BE PLACED WITHIN 1'-O"OF THE TOP OF <br /> SEE DETAIL 12,18/F53 FOR VENT SENSOR SEE DETAIL 58 I i SUMP. <br /> STACK 18/F55.0 I 4. USE OPW RISER SUPPORT BRACKETS(BRACELETS) <br /> NOTE: BRAVO TEST PORT WITH <br /> THE DISPENSER SUMPS AND VENT SUMPS CONNECTION HOSE�GA <br /> HAVE PROPYLENE GLYCOL IN THE _ NOTE: XA10 � <br /> INTERSTITIAL SPACE PENETRATION FITTING THE TANK AND THE TANK SUMPS HAVE CALCIUM CHLORIDE IN THE <br /> CONTRACTOR TO LABEL FILL PORTS WITH 3"OVER 2"DOUBLE INTERSTITIAL SPADE. ����w`��+�j+ ^ <br /> TYPE OF FILL. WALL VENT PIPE DEFLEG70R PLATE CONTRACTOR TO LABEL FILL PORTS WITH TYPE OF FILL. <br /> 18 SUMP SENSOR NOTE 1 VENT SUMP SECTION 6 DIESEL, FILL, AND VENT DETAIL FUELING CANOPY <br /> SCALE: N.T.S. FOR NEW INSTALLATIONS SCALE: 3/4" = 1'-0" SCALE: 3/4" = V-0- <br /> 1"CONDUIT TO INTRINSICALLY SAFE 3/4"CONDUIT FOR PUMP POWER <br /> GUTTER AT MONITOR CONTROL 33 TO ELECT. PANEL-1 PER TANK <br /> PANEL(1 PER TANK) <br /> 3/4"CONDUIT TO TLM 33 2226 Jackson Avenue <br /> BRINE INTERSTITIAL SENSOR 58 <br /> Escalon, California 95320 <br /> 2-PIN CONNECTOR OF GABLE. EXPLOSION PROOF JUNCTION BOX <br /> ATTACHES TO GCVP VALVE TURBINE PUMP 24 <br /> i <br /> VALVE ENCLOSURE ASSEMBLY <br /> 36"WATERTIGHT MANHOLE O <br /> CANISTER OUTLET MUST BE 12'-0"MIN. SUMP SENSOR, INSTALL AT Q LEAK DETECTOR <br /> ABOVE GRADE. PRESSURE VACUUM SEE 20/FS5.0 FOR GAS TANK LOWEST POINT TO ENSURE LIQUID 58 / DEVELOPER` <br /> VENT VALVE BEYOND MANIFOLD THE 91 GAS TO THE FOR UNLEADED GAS DETECTION AT EARLIEST P055IBL <br /> PRESSURE VALGUM VENT VALVE 87 GAS, SEE 20/FS5.0 MOMENT <br /> SENSOR HOUSING USE SIPHON JET PORT FOR <br /> VACUUM GENERATION <br /> --- -- - ------------------ 0 DOUBLE WALL <br /> -_ CHECK VALVE FOR / CONTAINMENT SUMP 0 <br /> -� \IN, <br /> SQUARE TUBE FRAME LEAK DETECTOR X VACUUM SENSOR AND HOSE 59 <br /> PIPE MANIFOLDGANISTERASSEMBLY 73 Q 2"x24" FLEXIBLE CONNECTOR 27 _ <br /> MALE BY MALE SWIVEL REVISIONS: <br /> v 2"BALL VALVE(MAKE HANDLE <br /> r <br /> ACCESSIBLE FROM GRADE 30 1 PLAN REVIEW CHANGES 12/21/2022 <br /> 2"SCH.40 FRP. BELL x FEMALE ) <br /> CANISTER SUPPORT ----� I 3"SQUARE w <br /> BRAGKET AND FASTENERS. 36 j--r TUBE FRAME w THREADED ADAPTER Q PLAN REVIEW CHANGES 01/09/2023 <br /> I I � 3"OVER 2"PRODUCT,TO <br /> o I I 3"x2"BOOT WITH TEST PORT DISPENSERS 3 FUEL CHANGES 2/03/2023 <br /> I I 4 TANK CHANGE 2/20/2023 <br /> 2"THREADED VENT PIPE 2"THREADED VENT PIPE BEYOND <br /> Irl `y �- <br /> I�I DIESEL TURBINE SUMP PLAN VIEW 5 TANK CHANGE 3-14-23 <br /> ° I I 7 6 EHD-Hazmat Comments 4-7-23 <br /> I - <br /> CORD GRIP 2"F.G. PIPE SCALE: 3/4" = 1'-0" <br /> c I I PROFESSIONAL SEALS: <br /> J BOX, EPDXY ENGLOBED z OPW WATERTIGHT FRP LID 18 <br /> CONNECTIONS / <br /> BRINE SUMP INTERSTITIAL SE...ARC <br /> MONITORING <br /> INLET PIPING KITfill <br /> ° <br /> 24 TURBINE PUMP <br /> ° ��'•. NOV,, 2023 ; <br /> 2"x 1/2"NPT REDUCING TEE ////// z JUNCTION BOX <br /> SUMP SENSOR CONTAINMENT SUMP REDUCER <br /> \\ FIBERGLASS REDUCER ON THE qJ^., RE AL O� <br /> i KWIK FIT ELEC, 7 OUTSIDE TO ENSURE WATER <br /> ITTING 42 1"CONDUIT TO INTRINSICALLY TIGHTNESS <br /> VENT SUPPORT RACK 2/3/2023 <br /> i VENT LINE SUMP SAFE GUTTER AT MONITOR <br /> VENT SUPPORT RACK <br /> z I 40 CONTROL PANEL 0 PER TANK) 27 2"x24"FLEXIBLE CONNECTOR <br /> 2 33 MALE BY MALE SWIVEL PROJECT NUMBER: PROJECT DATE: <br /> 1"CONDUIT "FLEX 24" 44 3/4"CONDUIT TO FILL/VAPOR <br /> o I SUMP JUNCTION BOX 21-004 I $-4-2021 <br /> PENETRATION BOOTS 3/4"CONDUIT TO ELECT. BARBED FITTINGS <br /> 6 RACK SYSTEM FOR PANEL(PUMP POWER) VACUUM HOSE SHEET CONTENTS: <br /> 5-PRODUCT PENETRATION BOOT <br /> THIS PIPE TO FILL SUMP <br /> 12"SQUARE <br /> 12"S U R PAINT ALL SUMP SENSOR, INSTALL AT LOWEST DIESEL TANK SUMPS <br /> EXPOSED POINT TO ENSURE LIQUID DETECTION 58 TEST PORT WITH CONNECTION VENT DETAILS <br /> OUR INSTALLATION IS SIMILAR TO THIS. WE ONLY HAVE PIPING AT EARLIEST POSSIBLE MOMENT HOSE AND CAP <br /> NOTE: <br /> 2 VENTS TO CONNECT,87 UNLEADED AND 91 UNLEADED. 30" MIN,ABOVE ROOF OF ANY SEE DETAIL 18/FS5 FIBERGLASS CONTAINMENT <br /> SEE DETAIL 12/FS5.0 STRUCTURE WITHIN 10' SUMP TO TANK COLLAR INSIDE <br /> AND OUT TO INSURE WATER <br /> i TIGHTNESS <br /> 59 VACUUM SENSOR BOX SHEET NUMBER: <br /> 20 CANISTER AT VENT RISER 12 VENT RISER 8 DIESEL TURBINE CONTAINMENT - VIEW ELEVATION <br /> SCALE: N.T.S. SCALE: N.T.S. SCALE: 3/4" = 1'-0" FS5mO <br />