My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2023
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACKSON
>
2226
>
2300 - Underground Storage Tank Program
>
PR0548528
>
INSTALL_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2024 2:43:27 PM
Creation date
8/24/2023 12:57:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2023
RECORD_ID
PR0548528
PE
2351
FACILITY_ID
FA0000370
FACILITY_NAME
ORLANDOS ESCALON
STREET_NUMBER
2226
STREET_NAME
JACKSON
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22727016
CURRENT_STATUS
01
SITE_LOCATION
2226 JACKSON AVE
P_LOCATION
06
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\lsauers1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
260
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
April 9,2023 <br /> RESPONCES to Email of April 7,2023 <br /> 1. Clarify which overfill model will be used and provide updated plans and cut sheets. The <br /> application page 7 of 8, section G the model number provided was 71 SO 410CBT. On the parts <br /> list, 71 SO-41OCT,was listed as the product number. The cut sheets provided are for 71 SO- <br /> 410CB and 71 SO-410. The correct is 71 SO-410CB. Changed all references. <br /> 2. Clarify which annular sensors will be used.And provide updated plans. On page 8 of 8 section I <br /> of the application,the model number for the interstitial space of each secondarily-contained tank <br /> is listed as 304. This is not a tank annular sensor. It is 303,you have the cut sheet from previous <br /> submittal. Revised page <br /> 3. Clarify the UDC model number. Page 8 of 8 section J,does not match the part list. Revised <br /> 4. Submit cut sheet for the BRAVO F-series penetrations. SEE ATTACHED <br /> 5. Update page FS1.0"Additionally,under"California Fire Code Notes"the county listed is for <br /> Sacramento County not San Joaquin County. Please make sure it is corrected. REVISED <br /> 6. Update the plans to include accurate deadman information. Page FS2.0,the deadmen are listed as <br /> 20 in x 8 in x 18 ft. According to the Xerxes tank anchoring system,it is 18 in x 9 in x 18 ft <br /> (WxHxL). FS6.0#18: the length of the deadmen are incorrect. Please refer to the Xerxes tank <br /> anchoring system. Please clarify the type of deadmen and size used on page FS6.0. A two tank <br /> deadmen is not consistent with the buoyancy calculation and Xerxes tank cut-sheet. REVSIED <br /> DETAILS <br /> 7. Update the plans to show proper tank,piping, and sumps orientation. The orientation does not <br /> match on FS7.0,FS3.0,FSL1, and FS 1.2. Multiple orientations are shown.Revised FS1.1,FS1.2 <br /> to match others <br /> 8. Please clarify why the plans appear to show eletrical wires attached to the bottom of multiple spill <br /> containers. REMOVED,NOT REQUIRED <br /> 9. Update the plans to include test ports in the STP and fill sumps. ALL SUMPS HAVE TEST <br /> PORTS? <br /> 10. Review and update the buoyancy calculation to contain accurate information. <br /> 1. 2 deadman are listed,cut sheets indicate 4,the weight of the deadmen does not match the <br /> calculation on Xerxes tank anchoring system sheet. REVISED <br /> 2. Tank displaced water volume does not account for the tank secondary containment and <br /> sumps SEE"OTHER"IN CALCS <br /> 3. Calculation does not account for the ribs on the tanks.RIBS ARE PART OF <br /> SECONDARY COTAINMENT <br /> 4. Length of the tank is inconsistent on the 20k gallon tank buoyancy calculation. <br /> REVISED <br /> 5. Weight of the tank does not match the Xerxes tank cutsheet on the 20k gal Ion tank <br /> buoyancy calculation. REVISED <br /> 6. 10k x 10k gallon tank buoyancy calculation: The deadmen information does not match <br /> the cutsheet. REVISED <br /> K12 Architects,Inc. 3090 Fite Circle,Suite 104, Sacramento,CA. 95827 Phone: (916)455-6500 Fax:(916)455-8100 <br />
The URL can be used to link to this page
Your browser does not support the video tag.