My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2023
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACKSON
>
2226
>
2300 - Underground Storage Tank Program
>
PR0548528
>
INSTALL_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2024 2:43:27 PM
Creation date
8/24/2023 12:57:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2023
RECORD_ID
PR0548528
PE
2351
FACILITY_ID
FA0000370
FACILITY_NAME
ORLANDOS ESCALON
STREET_NUMBER
2226
STREET_NAME
JACKSON
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22727016
CURRENT_STATUS
01
SITE_LOCATION
2226 JACKSON AVE
P_LOCATION
06
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\lsauers1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
260
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJ O A Q U I N Environmental Health Department <br /> COUNTY <br /> I. MONITORING: All monitoring equipment must be listed in the State Water Resources Control Board <br /> Division of Clean Water Program Local Guidance Letter 113. <br /> Check Code <br /> Box Section <br /> All secondary containment units (e.g. tank annular spaces, secondary piping, sumps, <br /> 23 CCR <br /> under-dispenser containment, etc.) monitored for leaks using approved electronic leak <br /> 2636(f) detections stems. <br /> Electronic monitoring sensors located at the following points: <br /> ° At the bottom of the interstitial space of each secondarily-contained tank, <br /> positioned as near as possible to the bottom of the tank. <br /> Manufacturer VEEDER-ROOT Model V/R794380-303 <br /> ° In each collection sump, positioned as near as possible to the bottom of the <br /> collection sump. Additionally, in any sump acting as secondary containment for <br /> unused tank openings which connect to the primary space. <br /> Manufacturer VEEDER-ROOT Model V/R794380-208 <br /> 23 <br /> 26 CCR <br /> 2630(d) ° In dispenser pans which do not drain into secondary containment piping. (Note: <br /> A mechanical switch which triggers a shear valve may be substituted but this <br /> system will not qualify for the annual line tightness test exemption under 23 CCR <br /> 2636(g)). <br /> Manufacturer VEEDER-ROOT Model V/R794380-208 <br /> ❑Along secondarily-contained pipe runs which do not meet the 1/8 inch-per-foot <br /> slope requirement, positioned in the depressed or low-lying areas. <br /> Manufacturer N/A Model <br /> 23 CCR Automatic line leak detectors installed to monitor underground pressurized piping. <br /> 2636(f) <br /> VE HSC Manufacturer VEEDER-ROOT Model V/R1-848480-001 <br /> 25290.1 h <br /> 25290.2 <br /> Alarm panel provides both audible and visual alarms. It is located in a protected area <br /> ❑ 23 CCR and within sight and hearing distance of on-site personnel and hard-wired to a <br /> 2632(c)(2)(B) dedicated circuit. <br /> Manufacturer VEEDER-ROOT Model TLS 350 Plus <br /> J. OTHER COMPONENT INFORMATION: <br /> COMPONENT MANUFACTURER MODEL COMPOSITION <br /> SUMP Bravo XE-DW42SMP-OT FIBERGLASS <br /> XE-DW48SMP-WT <br /> UNDER-DISPENSER <br /> CONTAINMENT BRAVO B8380-D30 FIBERGLASS AND STEEL <br /> BRAF-32S-T-F <br /> PENETRATIONS BRAVO BRAF-43S-T-F FIBERGLASS <br /> BRAF-075-0-F <br /> Type text heAof 8 <br />