SAN J 0 A Q I I I Irl Environmental Health Department <br /> CCUN r <br /> Hazardous Materials Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Airgas USA, LLC 3970 WILCOX RD, Stockton August 24, 2023 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 5 HSC 25505(a)(1) Failed to electronically submit hazardous materials inventory for all reportable materials on site. <br /> OBSERVATION: The hazardous materials inventory is inaccurate. Per Juan Garibay,the facility has not stored any <br /> sulfur dioxide on site for over a year. <br /> REGULATION GUIDANCE:Any material that meets or exceeds the reportable quantity shall be reported in the <br /> facility's business plan. <br /> CORRECTIVE ACTIONS: Immediately log into the California Environmental Reporting System (CERS)at <br /> http://cers.calepa.ca.gov/, update the hazardous material inventory, and submit to the EHD for approval. <br /> This is a repeat violation, Class II. <br /> 6 HSC 25505(a)(2) Failed to electronically submit a site map with all required content. <br /> OBSERVATION:A site map is inaccurate.The following items need to be updated: <br /> -sulfur dioxide was not observed next to the ammonia as indicated on the map <br /> -flammable gases were not observed next to the ammonia enclosure as indicated on the map <br /> -flammable gases were not observed on the east side of the facility <br /> -flammable gases were not observed on the east and south side of the Dewar Storage/Cargo bin area <br /> -the map did not address storm/sewer drains <br /> -the map did not address internal roads <br /> REGULATION GUIDANCE:A site map shall contain a north orientation, loading areas, internal roads, adjacent <br /> streets, storm and sewer drains, access and exit points, emergency shutoffs, evacuation staging areas, hazardous <br /> material handling and storage areas, and emergency response equipment. <br /> If a site map element is not applicable for your facility then list it on the map and label as"NA". <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS)at <br /> http://cers.calepa.ca.gov/, upload the correct or updated information, and submit to the EHD for approval. <br /> This is a minor violation. <br /> 9 HSC 25508.2 Failed to annually review and certify that the HMBP is complete and accurate by the due date. <br /> OBSERVATION: The business plan information has not been reviewed and resubmitted in the California <br /> Environmental Reporting System (CERS)annually by the due date, January 15. The business plan was submitted <br /> late in 2022 (01/17/2022)and 2023 (02/15/2023). <br /> REGULATION GUIDANCE: The hazardous materials inventory shall be submitted by January 15 of each calendar <br /> year and may be submitted beginning November 1 of the previous year <br /> CORRECTIVE ACTION: Submit a statement to SJC EHD stating that the business will annually certify/submit the <br /> annual HMBP to CERS by January 15. <br /> This is a minor violation. <br /> FA0009938 PR0519972 SCO01 08/24/2023 <br /> EHD 19-01 Rev.12/06/2021 Page 2 of 4 Hazardous Materials Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />