My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0015801
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PATTERSON PASS
>
20042
>
2600 - Land Use Program
>
PA-2200137
>
SU0015801
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/27/2024 1:55:05 PM
Creation date
8/31/2023 1:18:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0015801
PE
2675
FACILITY_NAME
PA-2200137
STREET_NUMBER
20042
Direction
W
STREET_NAME
PATTERSON PASS
STREET_TYPE
RD
City
TRACY
Zip
95377-
APN
20910019, 99B-7885-002, 99B-7590-1-3
ENTERED_DATE
8/29/2023 12:00:00 AM
SITE_LOCATION
20042 W PATTERSON PASS RD
RECEIVED_DATE
11/14/2023 12:00:00 AM
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
987
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4 Environmental Analysis <br /> 4.3 Air Quality <br /> Table 4.3-8. Estimated Maximum Annual Construction Criteria Air Pollutants Emissions <br /> TotalEmissions(tons per year) <br /> ROG NOxCO sox PM10 <br /> No Reductions 1.09 9.35 10.98 0.03 1.25 0.72 <br /> Rule 9510 and Dust Control Reductions 1.09 5.22 10.98 0.03 0.76 0.41 <br /> SJVAPCD Threshold 10 10 100 27 15 10 <br /> Threshold Exceeded? No No No No No No <br /> CO-carbon monoxide;NOx-nitrogen oxide;PM,o-particulate matter between 2.5 and 10 micrometers in diameter;PM2.5-particulate matter 2.5 micrometers <br /> in diameter or smaller;ROG-reactive organic gas;SJVAPCD-San Joaquin Valley Air Pollution Control District;SO.-sulfur oxide <br /> Table 4.3-9. Estimated On-site Maximum Daily Construction Criteria Air Pollutants <br /> Emissions <br /> Emissions(lbs/day) <br /> Total Project Emissions ROG NOxCO sox PM10 <br /> No Reductions 11.92 99.99 98.44 0.25 18.38 10.83 <br /> Rule 9510 and Dust Control Reductions 11.92 51.46 98.44 0.25 8.68 5.33 <br /> SJVAPCD On-site Emissions Threshold 100 100 100 100 100 100 <br /> Threshold Exceeded? No No No No No No <br /> CO-carbon monoxide;NOx-nitrogen oxide;PM,o-particulate matter between 2.5 and 10 micrometers in diameter;PM2.5-particulate matter 2.5 micrometers <br /> in diameter or smaller;ROG-reactive organic gas;SJVAPCD-San Joaquin Valley Air Pollution Control District;SO.-sulfur oxide <br /> As shown in Table 4.3-8, annual construction emissions would not exceed the SJVAPCD annual <br /> significance thresholds for any pollutants, both with and without reductions. As shown in Table <br /> 4.3-9, maximum daily onsite construction emissions would not exceed the SJVAPCD's localized <br /> significance threshold of 100 lbs/day for ROG, NOx, CO, SO, PM1o, or PM2.5. The SJVAPCD <br /> recommends that an AAQA be conducted when onsite emissions from any criteria pollutant would <br /> equal or exceed applicable significance thresholds or when onsite emissions would equal or <br /> exceed 100 lbs/day for any pollutant. Therefore, an AAAA was not performed for the Project. <br /> Operational Emissions <br /> Project operational emissions were estimated using CalEEMod to include area, mobile, and off- <br /> road source emissions. This included potential emissions from landscaping, worker commutes, <br /> and heavy trucks used during maintenance. Emissions from energy use were not included since <br /> electricity used onsite would be generated from the onsite batteries. Table 4.3-10 presents the <br /> estimated maximum annual operational emissions in tons per year with a comparison to <br /> SJVAPCD thresholds. The PM2.5 significance threshold is based on the BAAQMD threshold of 10 <br /> tons per year. Detailed emissions calculations are provided in Appendix D. <br /> Table 4.3-10. Estimated Maximum Annual Operational Criteria Air Pollutants Emissions <br /> ROG NOxCO sox PM10 <br /> Emission Source Tons per Year <br /> Area,Mobile,and Offroad 0.006 0.03 0.04 0.0001 0.002 0.0012 <br /> SJVAPCD Threshold 10 10 100 27 15 10 <br /> Threshold Exceeded? No No No No No No <br /> CO-carbon monoxide;NOx-nitrogen oxide;PM,o-particulate matter between 2.5 and 10 micrometers in diameter;PMz 5-particulate matter 2.5 micrometers <br /> in diameter or smaller;ROG-reactive organic gas;SJVAPCD-San Joaquin Valley Air Pollution Control District;SO.-sulfur oxide <br /> Griffith Energy Storage Project 4.3-26 Tetra Tech/SCH 2022120675 <br /> Draft Environmental Impact Report August 2023 <br />
The URL can be used to link to this page
Your browser does not support the video tag.