Laserfiche WebLink
Q 5:DIESEL 10 <br />TYP:2.0/3.OIN FIBERGLASS <br />2.0IN DIA LEN: 350 FEET <br />3.OIN DIA LEN: 0 FEET <br />SHUTDOWN RATE: 3.0 GPH <br />LOW. PRESSURE SHUTOFF:NO <br />LOW PRESSURE : 0 PSI <br />T 4:DIESEL <br />DISPENSE MODE: <br />STANDARD <br />SENSOR: NON -VENTED <br />PRESSURE OFFSET: 0.OPSI <br />MECHANICAL BLENDER: NO <br />LINE LEAK LOCKOUT SETUP <br />LOCKOUT SCHEDULE <br />DAILY <br />START TIME: DISABLED <br />STOP TIME : DISABLED <br />I <br />LIQUID SENSOR SETUP- - - <br />- - - <br />L 1:91 ANN <br />NORMALLY CLOSED <br />I CATEGORY : ANNULAR SPACE <br />L 2:87 2 ANN <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />L 3:87 1 ANN <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />L 4:DIESEL ANN <br />TRI-STATE (SINGLE FLOAT) <br />CATEGOR`! : ANNULAR SPACE <br />L 8:91 STP <br />CATEGORY :(STPGLE SUMPLOAT) <br />L 9:87 2 STP IN -TANK ALARMS <br />TRI-STATE (SINGLE FLOAT) ALL:OVERFILL ALARM <br />CATEGORY STP SUMP ALARM <br />111\\ALL:MAXHPRODUCT TALARM <br />L10:87 1 STP <br />TRI-STATE (SINGLE FLOAT:• <br />CATEGORY : STP SUMP <br />L11:DIESEL.STP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />L12:DISP 1-2 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY DISPENSER PAN <br />L13:DISP 3-4 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L14:DISP 5-6 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L15:DISP 7-8 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L16:DISP 9-10 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L17:DISP 11-12 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />OUTPUT RELA`. SETUP <br />R 3:REM0TE ALARM <br />TYPE: <br />MOMENTARY <br />NORMALLY CLOSED <br />IN -TANK ALARMS <br />ALL:OVERFILL ALARM <br />ALL:HIGH PRODUCT ALARM <br />ALL:MAX PRODUCT ALARM <br />R 4:ALARM <br />TYPE: <br />MOMENTARY <br />NORMALL`! OPEN <br />PLLD LINE DISABLE SETUP <br />Q 1:SUPER <br />IN -TANK ALARMS <br />ALL:HIGH WATER ALARM <br />LIQUID SENSOR ALMS <br />L B:FUEL ALARM <br />L.12:FUEL ALARM <br />L13:FUEL ALARM <br />L14:FUEL ALARM <br />L15:FUEL ALARM <br />L16:FUEL ALARM <br />L.17:FUEL ALARM <br />L 8:SENS0R OUT ALARM <br />L12:SENSOR OUT ALARM <br />L13:SENS0R OUT ALARM <br />L14:SENS0R OUT ALARM <br />L15:SENSOR OUT ALARM <br />L.16:SENSOR OUT ALARM <br />L17:SENS0R OUT ALARM <br />L G:SHORT ALARM <br />L12:SHORT ALARM <br />L13:SHORT ALARM <br />L14:SHORT ALARM <br />L15:SHORT ALARM <br />L16:SHORT ALARM <br />L17:SHORT ALARM <br />ISD SITE ALARMS <br />ISD GROSS PRES FAIL <br />ISD DEGRD PRES FAIL <br />ISD VAPOR LEAK FAIL <br />ISD VP PRES FAIL <br />ISD VP STATUS FAIL <br />ISD SETUP FAIL <br />ISD SENSOR OUT FAIL <br />1 ISD HOSE ALARMS <br />ALL:GROSS COLLECT FAIL <br />ALL:DEGRD COLLECT FAIL <br />ALL:FLOW COLLECT FAIL <br />Q 2:REGULAR <br />LIQUID SENSOR ALMS <br />L 9:FUEL ALARM <br />L.10:FUEL ALARM <br />L.12 : F UEL ALARM <br />L.13:FUEL ALARM <br />L.14:FUEL ALARM <br />L.15:FUEL ALARM <br />L.16:FUEL ALARM <br />L17:FUEL ALARM <br />L 9:SENSOR OUT <br />ALARM <br />L10:SENSOR OUT <br />ALARM <br />L.12:SENS0R OUT <br />ALARM <br />L.13:SENSOR OUT <br />ALARM <br />L14:SENSOR'OUT <br />ALARM <br />L15:SENS0R OUT <br />ALARM <br />L.16:SENSOR OUT <br />ALARM <br />L.17:SENSOR OUT <br />ALARM <br />