Laserfiche WebLink
Environmental Health Department <br />Time In: <br />10:01 am <br /> 9:46 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: Owner/Operator: BROOKSIDE CROSSING LLC <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 5322 FEATHER RIVER DR, STOCKTON 95219 <br />Date: 07/18/2023Name of Facility: BROOKSIDE CROSSING APTS (PHASE I) <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #22 Skimmer Assembly <br />OBSERVATIONS: All three skimmers lack weirs. Install weirs within one week. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br /> #35 Flow Meters <br />OBSERVATIONS: The flow meter was observed non-operational. Repair/replace today. (REPEAT) <br />CALCODE DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br /> #38 Filter Cleaning and Maintenance <br />OBSERVATIONS: The influent gauge was observed at 22 psi which was past the "clean filter" psi. Clean filter today. <br />CALCODE DESCRIPTION: All filters shall be maintained in accordance with manufacturer's specifications. (CBC 3123B) Pressure gauge <br />located on the filter shall be marked with the clean startup reading. (CBC 3125B) Each filter vessel shall be provided with valves so that it <br />can be isolated from the recirculation system for repairs and backwashing. (CBC 3128B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F <br />7.6 <br />5.2 <br />30 Combined chlorine:ppm <br />NOTES <br />Pool <br />Influent 22 psi <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0002926 PR0360011 SC001 07/18/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD